HOME
SBOX
THOMX
MINICAV
Utilities
MINICAV orders
MINICAV installation
MINICAV commissioning
MINICAV control command
Status of commissioning, report also here plots are reports., Page 1 of 5
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
89 Entries
Goto page 1,
2
,
3
,
4
,
5
Next
All
ID
Date
Author
Status
Type
Category
Location
Title
Text
40
Thu Oct 21 10:24:01 2021
Blanc
Fixed
info
utilities
Other
Presentations
Here the first part
of all the presentations since the beginning
of the project.
41
Thu Oct 21 10:30:38 2021
Blanc
Fixed
info
utilities
Other
Presentations
Here the second part
of all the presentations since the beginning
of the project.
42
Thu Oct 21 10:32:54 2021
Blanc
Fixed
info
utilities
Other
Presentations
Here the last part
of all the presentations since the beginning
of the project.
7
Mon Apr 19 19:11:47 2021
Manar Amer
Fixed
report
mechanics | software
Other
Distances between mirrors
At the reference zero the
distance between the mirrors is (taken from
a reference presentation "status9nov2020"
43
Thu Dec 2 16:12:17 2021
Aurélien Martens
Fixed
report
mechanics | software
Optical room
new smaract positions
M1 and M2 at 5.1085mm and M3 and M4 at
-2.9mm
11
Tue May 4 15:56:33 2021
Manar Amer
Fixed
report
mechanics | lasers and optics | software
Other
Distances between mirrors
New update on the position of the Motors
for the cavity
***** we moved
23
Fri Oct 1 16:55:47 2021
Blanc
Fixed
info
mechanics | lasers and optics | detectors and electronics
Optical room
1GHz oscillator Frep measurement
a previous cavity FSR measurement was giving
a center frequency around 867.5MHz.
the
present 1GHz oscillator Frep measurement
35
Tue Oct 19 18:27:20 2021
Ronic Chiche
Fixed
report
mechanics | lasers and optics | detectors and electronics
Optical room
PZT resonant frequencies
we have excited the PZT with a swept sinus
wave from 1kHz to 10kHz and from 10kHz to
100kHz.
39
Thu Oct 21 09:44:35 2021
Blanc
Fixed
info
mechanics | lasers and optics | detectors and electronics
Optical room
1GHz oscillator Frep measurement
The optical spectrum of the GHz oscillator:
FWHM ~ 4nm
25
Mon Oct 4 15:10:17 2021
Aurélien Martens
Fixed
report
mechanics | detectors and electronics | software
Optical room
new position of smaract motors
following the measuremetn at 879.9 MHZ
of the laser theoptical cavity length has
been adjusted to that value from 876MHz setting
5
Mon Apr 19 18:41:03 2021
Manar Amer
Fixed
report
mechanics | cabling | software
Other
Setting up the Motors
A document attached that describes the
procedure needed to:
- connect the motors
4
Thu Apr 15 19:54:19 2021
Manar Amer
Fixed
report
mechanics | cabling
Other
Mirrors Mottors Connections
Added the cabling to the categories
3
Thu Apr 15 19:45:08 2021
Manar Amer
Fixed
report
mechanics
Other
Mirrors Mottors Connections
* The connections to control the motors
of the mirrors are connected in the order
stated :
1
Tue Mar 23 18:33:16 2021
Ronic Chiche
Fixed
info
lasers and optics | detectors and electronics
Optical room
Phase noise measurement of the Amplitude MIKAN
Installation of the MIKAN.
powermeter (with OD1) just after the
oscillator shows 440mW for 4A of the MIKAN
2
Tue Apr 6 09:25:47 2021
Ronic Chiche
Fixed
info
lasers and optics | detectors and electronics
Optical room
Phase noise measurement of the Amplitude MIKAN
Coupling into a 50-50% fiber coupler using
the Thorlabs XYZ table NanoMax TS.
We reached 117mW after the 50% arm
10
Fri Apr 30 17:41:10 2021
Aurélien Martens
Fixed
report
lasers and optics | detectors and electronics
Optical room
Lock, cavity length and finesse estimate
Ronic just suceeded in obtaining a reasonably
good lock on the cavity. Air flow is switched
off.
13
Wed Jun 30 20:26:38 2021
Kevin Dupraz
Under Process
info
lasers and optics | detectors and electronics
Optical room
Cameras Calibration
After installing cameras the actual calibration
are :
NF_Refl: acA1920-40gm
15
Mon Sep 6 18:17:24 2021
Kevin Dupraz
Under Process
report
lasers and optics | detectors and electronics
Optical room
Cavity lock and references
Cavity is lock and optimized with the NKT.
Input power is maximized (10mW).
Cavity mode is in attachement.
16
Tue Sep 7 11:05:47 2021
Aurélien Martens
Fixed
report
lasers and optics | detectors and electronics
Optical room
Lock, cavity length and finesse estimate
we observed that the transmitted light
coming from the cavity is made of the cavity
mode light and the scattered light on the
18
Tue Sep 7 17:48:50 2021
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
Locking of the cavity and setup changing
We change the setup a bit to have the same
polarization on the photodiode and the PDH
(in reflexion of the cavity). CF: schematics
Goto page 1,
2
,
3
,
4
,
5
Next
All