HOME SBOX THOMX MINICAV Utilities
MINICAV orders MINICAV installation MINICAV commissioning MINICAV control command
  Status of commissioning, report also here plots are reports.  Not logged in ELOG logo
Message ID: 15     Entry time: Mon Sep 6 18:17:24 2021
 Author: Kevin Dupraz 
 Status: Under Process 
 Type: report 
 Category: lasers and optics | detectors and electronics 
 Location: Optical room 
 Title: Cavity lock and references 

Cavity is lock and optimized with the NKT. Input power is maximized (10mW).

Cavity mode is in attachement. The reference on camera with BeamProfiler Matlab code is the following:

FF_refl: [2.0883    1.1606]

NF_refl: [5.3869    3.9327]

FF_inj: [1.9491    1.3980]

NF_inj: [5.6431    3.5234]

Attachment 1: NF_Trans_2021-09-06__17-49-00.bmp  2.246 MB
ELOG V3.1.4-395e101