HOME
SBOX
THOMX
MINICAV
Utilities
MINICAV orders
MINICAV installation
MINICAV commissioning
MINICAV control command
Status of commissioning, report also here plots are reports., Page 3 of 5
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
89 Entries
Goto page
Previous
1
,
2
, 3,
4
,
5
Next
All
ID
Date
Author
Status
Type
Category
Location
Title
Text
38
Wed Oct 20 15:27:51 2021
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Amplitude GHz oscillator phase noise with PZT effect
Thorlabs PZT datasheet.
Reference: PC4QR
46
Fri Dec 10 16:57:56 2021
Kevin Dupraz
Under Process
report
lasers and optics
Optical room
Manip 10 12 2021 (optimization injection Burst)
Manip 10/12/2021
Après recherche de la résonnance
principale
47
Tue Dec 14 12:59:07 2021
Kevin Dupraz
Under Process
report
lasers and optics
Optical room
Manip 14 12 2021 injection optimization (and calibration)
Matin :
moteurs :
M1, M2 (plans): 5.110500m
48
Thu Dec 16 10:40:55 2021
Kevin Dupraz
Under Process
report
lasers and optics
Optical room
Manip 14 12 2021 injection optimization (and calibration)
Après-midi :
* Optimisation
de l'alignement en injection pour avoir
49
Thu Dec 16 12:12:10 2021
Kevin Dupraz
Under Process
report
lasers and optics
Optical room
Manip 16 12 2021 montée en puissance
Matin:
* Redémarrage Tangor 4W
- couplage 15%
50
Thu Dec 16 12:13:52 2021
Kevin Dupraz
Under Process
report
lasers and optics
Optical room
Manip 16 12 2021 montée en puissance
51
Thu Dec 16 18:16:12 2021
Blanc
Under Process
info
lasers and optics
Optical room
Changements et ajout d'optiques
Optiques ajoutées :
- splitter 90/10 au début
de la voie de réflexion, pour éjecter
52
Fri Dec 17 17:03:34 2021
Kevin Dupraz
Under Process
report
lasers and optics
Optical room
Manip 17 12 2021 reprise réf nouvelle injection pour polarisation
Tangor : 4.2W
* Réalignement de l'injection
suite aux modifications :
55
Thu May 19 10:04:05 2022
Blanc
Under Process
report
lasers and optics
Optical room
Changement cadence et duty cycle + ref cam
- Prise des nouvelles ref caméras
: NF{709;371} , FF{389;280} [Image 1 &
2]
56
Tue Jun 14 11:16:37 2022
Blanc
Under Process
issue
lasers and optics
Optical room
Problèmes Cavitée
Précédentes ref pour lesquelles
la manip fonctionnait :
Caméras :
57
Tue Jan 10 18:04:20 2023
Blanc
Fixed
info
lasers and optics
Optical room
Données pour la baisse en cadence
Position Cam :
692;363 NF_inj
520;193 FF_inj
7x
58
Wed Jan 18 17:52:33 2023
Blanc
Fixed
info
lasers and optics
Optical room
Tests et mesures lockline
Mesures de puissance fibres lockline :
AVANT POLISSAGE
injection premier étage
59
Thu Jan 19 14:56:27 2023
Blanc
Fixed
info
lasers and optics
Optical room
Tests et mesures lockline
60
Thu Jan 19 15:05:58 2023
Blanc
Fixed
info
lasers and optics
Optical room
Suite Mesures de puissance lockline
Changement d'AOM pour passer sur l'AOM
200 MHz.
Le schéma suivant récapitule
61
Thu Jan 19 18:20:02 2023
Blanc
Fixed
info
lasers and optics
Optical room
Suite Mesures de puissance lockline
62
Fri Jan 20 18:01:22 2023
Blanc
Fixed
info
lasers and optics
Optical room
Mesure de finesse
Fréquence centrale : 879.48 MHz
FWHM mesurée à la
main sans sweep : 120 / 130 KHz
63
Wed Jan 25 12:12:36 2023
Blanc
Fixed
info
lasers and optics
Optical room
Mesure de finesse
64
Wed Jan 25 12:18:25 2023
Blanc
Fixed
info
lasers and optics
Optical room
Position des miroirs et gain photodiode
Nouvelle position des miroirs :
5.198865 ; 5.199305 ; -2.9 ; -2.9
Photodiode de transmission, gain
65
Thu Jan 26 22:49:46 2023
Blanc
Fixed
info
lasers and optics
Optical room
Nouvelles positions moteurs et calibrations camera
Positions moteurs :
5.198865 ; 5.198596 ; -2.9 ; -2.9
Calibration caméras :
66
Mon Jan 30 14:39:52 2023
Blanc
Fixed
info
lasers and optics
Optical room
Mesures de Polarisation
En récupérant la transmission
du miroir M3 sphérique sortant de
la cavité, on a pu faire une mesure
Goto page
Previous
1
,
2
, 3,
4
,
5
Next
All
ELOG V3.1.4-395e101