21
Thu Sep 16 18:23:13 2021
Blanc
Fixed
info
lasers and optics
Optical room
Polarization Results in transmission
After data processing, I finally find the
polarization in transmissin of the FPC. As
you can see below, the polarisation is not
23
Fri Oct 1 16:55:47 2021
Blanc
Fixed
info
mechanics | lasers and optics | detectors and electronics
Optical room
1GHz oscillator Frep measurement
a previous cavity FSR measurement was giving
a center frequency around 867.5MHz.
the
present 1GHz oscillator Frep measurement
24
Mon Oct 4 14:57:04 2021
Aurélien Martens
Fixed
info
detectors and electronics | software
Optical room
ip adress of smaract driver
the ip adress of the smaract driver is
now 10.0.53.10:5000
please think about putting such
27
Mon Oct 4 15:38:43 2021
Aurélien Martens
Fixed
info
detectors and electronics
Optical room
phone is noise
doing the sensitivty measurement of the
piezo we observed satellite peaks around
800 to 900 Mhz. Removing the phones from
32
Tue Oct 5 18:24:53 2021
Ronic Chiche
Fixed
info
lasers and optics
Optical room
Locking with fast analog loop on AOM
in addition to the standard locking scheme
with the GHz laser PZT,
we added an AOM after the PDH modulation
33
Thu Oct 7 17:53:53 2021
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
Finess and coupling measurement
We did the measurement of the Finess and
coupling with the NKT, with 2 EOM, without
AOM (so the lock signal is noisy), on the
34
Fri Oct 8 16:02:19 2021
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
Setup and measurements
To summerize the results of this week :
We made the setup in attachement
5 and align it to have the good mode in the
37
Wed Oct 20 14:54:00 2021
Ronic Chiche
Fixed
info
lasers and optics | detectors and electronics
Optical room
Phase noise measurement of the Amplitude MIKAN
MIKAN phase noise and RIN measurements:
39
Thu Oct 21 09:44:35 2021
Blanc
Fixed
info
mechanics | lasers and optics | detectors and electronics
Optical room
1GHz oscillator Frep measurement
The optical spectrum of the GHz oscillator:
FWHM ~ 4nm
40
Thu Oct 21 10:24:01 2021
Blanc
Fixed
info
utilities
Other
Presentations
Here the first part
of all the presentations since the beginning
of the project.
41
Thu Oct 21 10:30:38 2021
Blanc
Fixed
info
utilities
Other
Presentations
Here the second part
of all the presentations since the beginning
of the project.
42
Thu Oct 21 10:32:54 2021
Blanc
Fixed
info
utilities
Other
Presentations
Here the last part
of all the presentations since the beginning
of the project.
44
Mon Dec 6 11:22:08 2021
Kevin Dupraz
Under Process
info
lasers and optics | detectors and electronics
Optical room
Cameras Calibration
45
Tue Dec 7 11:48:33 2021
Kevin Dupraz
Under Process
info
lasers and optics | detectors and electronics
Optical room
Cameras Calibration
After check a mistake has been found on
the magnification. This seems to be the good
calibration (feel free to cross check). The
51
Thu Dec 16 18:16:12 2021
Blanc
Under Process
info
lasers and optics
Optical room
Changements et ajout d'optiques
Optiques ajoutées :
- splitter 90/10 au début
de la voie de réflexion, pour éjecter
53
Mon Mar 28 17:10:33 2022
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
input and output power of the AOM 50MHz
Input power of the AOM :
150mW
output power of the AOM :
57
Tue Jan 10 18:04:20 2023
Blanc
Fixed
info
lasers and optics
Optical room
Données pour la baisse en cadence
Position Cam :
692;363 NF_inj
520;193 FF_inj
7x
58
Wed Jan 18 17:52:33 2023
Blanc
Fixed
info
lasers and optics
Optical room
Tests et mesures lockline
Mesures de puissance fibres lockline :
AVANT POLISSAGE
injection premier étage
59
Thu Jan 19 14:56:27 2023
Blanc
Fixed
info
lasers and optics
Optical room
Tests et mesures lockline
60
Thu Jan 19 15:05:58 2023
Blanc
Fixed
info
lasers and optics
Optical room
Suite Mesures de puissance lockline
Changement d'AOM pour passer sur l'AOM
200 MHz.
Le schéma suivant récapitule