HOME SBOX THOMX MINICAV Utilities
MINICAV orders MINICAV installation MINICAV commissioning MINICAV control command
  Status of commissioning, report also here plots are reports., Page 3 of 5  Not logged in ELOG logo
ID Date Author Status Typedown Category Location Title Text Attachments
  21   Thu Sep 16 18:23:13 2021 BlancFixedinfolasers and opticsOptical roomPolarization Results in transmissionAfter data processing, I finally find the
polarization in transmissin of the FPC. As
you can see below, the polarisation is not
 Polarisation_transmission_cavité.png 
  23   Fri Oct 1 16:55:47 2021 BlancFixedinfomechanics | lasers and optics | detectors and electronicsOptical room1GHz oscillator Frep measurementa previous cavity FSR measurement was giving
a center frequency around 867.5MHz.

the
present 1GHz oscillator Frep measurement
  
  24   Mon Oct 4 14:57:04 2021 Aurélien MartensFixedinfodetectors and electronics | softwareOptical roomip adress of smaract driverthe ip adress of the smaract driver is
now 10.0.53.10:5000

please think about putting such
  
  27   Mon Oct 4 15:38:43 2021 Aurélien MartensFixedinfodetectors and electronicsOptical roomphone is noisedoing the sensitivty measurement of the
piezo we observed satellite peaks around
800 to 900 Mhz. Removing the phones from
  
  32   Tue Oct 5 18:24:53 2021 Ronic ChicheFixedinfolasers and opticsOptical roomLocking with fast analog loop on AOMin addition to the standard locking scheme
with the GHz laser PZT,

we added an AOM after the PDH modulation
  
  33   Thu Oct 7 17:53:53 2021 BlancFixedinfolasers and optics | detectors and electronicsOptical roomFiness and coupling measurementWe did the measurement of the Finess and
coupling with the NKT, with 2 EOM, without
AOM (so the lock signal is noisy), on the
 scope_10.pngscope_12.png 
  34   Fri Oct 8 16:02:19 2021 BlancFixedinfolasers and optics | detectors and electronicsOptical roomSetup and measurementsTo summerize the results of this week :

We made the setup in attachement
5 and align it to have the good mode in the
 acquisition_lock_GHz.pngSignal_d'erreur_PDH_sur_GHz.pngRésonances_dûes_au_pic_à_30kHz_dans_le_phase_noise.pngClose_loop_vs_open_loop_GHz.pngminicav_setup_Lock_GHz.PNG 
  37   Wed Oct 20 14:54:00 2021 Ronic ChicheFixedinfolasers and optics | detectors and electronicsOptical roomPhase noise measurement of the Amplitude MIKANMIKAN phase noise and RIN measurements:




 MIKAN_optical_phase_noise_comparison_with_NKT_CW_oscillator_&_RIN_@54MHz.png 
  39   Thu Oct 21 09:44:35 2021 BlancFixedinfomechanics | lasers and optics | detectors and electronicsOptical room1GHz oscillator Frep measurementThe optical spectrum of the GHz oscillator:
FWHM ~ 4nm

 Spectre_GHz-3.PNG 
  40   Thu Oct 21 10:24:01 2021 BlancFixedinfoutilitiesOtherPresentationsHere the first part
of all the presentations since the beginning
of the project.
 2-Présentation_LAL_22_06_2020_Corrigée.pptx4-Présentation_LAL_29_06_2020_Corrigée.pptx5-Présentation_LAL_27_07_2020.pptx6-Présentation_LAL_30_11_2020.pptx7-Présentation_LAL_07_12_2020.pptx 
  41   Thu Oct 21 10:30:38 2021 BlancFixedinfoutilitiesOtherPresentationsHere the second part
of all the presentations since the beginning
of the project.
 8-Présentation_LAL_15_04_2021_elog.pptx9-Présentation_LAL_10_05_2021_elog.pptx10-Présentation_LAL_28_06_2021.pptx 
  42   Thu Oct 21 10:32:54 2021 BlancFixedinfoutilitiesOtherPresentationsHere the last part
of all the presentations since the beginning
of the project.
 12-Présentation_LAL_13_09_2021.pptx13-Présentation_LAL_27_09_2021.pptx14-Présentation_LAL_11_10_2021.pptxPrésentation_Amplitude_23_08_2021.pptx 
  44   Mon Dec 6 11:22:08 2021 Kevin DuprazUnder Processinfolasers and optics | detectors and electronicsOptical roomCameras Calibration 




 grab2021-12-06_10-51-34_325_microscope.bmpgrab2021-12-06_10-52-11_108_microscope_calib_05mm_ruler.bmp 
  45   Tue Dec 7 11:48:33 2021 Kevin DuprazUnder Processinfolasers and optics | detectors and electronicsOptical roomCameras CalibrationAfter check a mistake has been found on
the magnification. This seems to be the good
calibration (feel free to cross check). The
 Plot_of_NF_Trans_calib_hex2mm__2021-06-23__17-06-49.pngPlot_of_NF_Refl_calib_hex2mm__2021-06-23__16-59-26.png 
  51   Thu Dec 16 18:16:12 2021 BlancUnder Processinfolasers and opticsOptical roomChangements et ajout d'optiquesOptiques ajoutées :

- splitter 90/10 au début
de la voie de réflexion, pour éjecter
  
  53   Mon Mar 28 17:10:33 2022 BlancFixedinfolasers and optics | detectors and electronicsOptical roominput and output power of the AOM 50MHzInput power of the AOM :

150mW

output power of the AOM :
  
  57   Tue Jan 10 18:04:20 2023 BlancFixedinfolasers and opticsOptical roomDonnées pour la baisse en cadencePosition Cam :

692;363 NF_inj
520;193 FF_inj
 7x 
  58   Wed Jan 18 17:52:33 2023 BlancFixedinfolasers and opticsOptical roomTests et mesures locklineMesures de puissance fibres lockline :

AVANT POLISSAGE

injection premier étage
  
  59   Thu Jan 19 14:56:27 2023 BlancFixedinfolasers and opticsOptical roomTests et mesures lockline 




 AOM_250_drivé_à_160_MHz_sortie_fibre_bleue.pngschéma_mesures_lockline_18_01_2023.PNG 
  60   Thu Jan 19 15:05:58 2023 BlancFixedinfolasers and opticsOptical roomSuite Mesures de puissance locklineChangement d'AOM pour passer sur l'AOM
200 MHz.

Le schéma suivant récapitule
 schéma_mesures_lockline_19_01_2023.PNG20230119_124318.jpg 
ELOG V3.1.4-395e101