  70   Thu Feb 2 17:40:10 2023 BlancFixedinfolasers and opticsOptical roomSchéma Manip Ci-dessous le schéma actuel de la
manip.
 7_Minicav_setup_23_05_2022.PNG 
  20   Thu Sep 9 16:34:37 2021 BlancFixedinfolasers and opticsOptical roomRing light in the cavityWe put a diaphragm in the input beam but
it doesn't work to suppress the ring
light only but it attenuates the whole transmitted
  
  22   Fri Sep 24 09:55:35 2021 Manar AmerUnder Processreportlasers and opticsOptical roomReflection Line Polarization MeasuremetWith the help of Ronic the cavity was locked
in preparation to measure the polarization
of the reflection line when the cavity is
 Reflection_line.jpg 
  56   Tue Jun 14 11:16:37 2022 BlancUnder Processissuelasers and opticsOptical roomProblèmes CavitéePrécédentes ref pour lesquelles
la manip fonctionnait :

Caméras :
 Transmission.PNGNF_inj.PNGFF_inj.PNG 
  40   Thu Oct 21 10:24:01 2021 BlancFixedinfoutilitiesOtherPresentationsHere the first part
of all the presentations since the beginning
of the project.
 2-Présentation_LAL_22_06_2020_Corrigée.pptx4-Présentation_LAL_29_06_2020_Corrigée.pptx5-Présentation_LAL_27_07_2020.pptx6-Présentation_LAL_30_11_2020.pptx7-Présentation_LAL_07_12_2020.pptx 
  41   Thu Oct 21 10:30:38 2021 BlancFixedinfoutilitiesOtherPresentationsHere the second part
of all the presentations since the beginning
of the project.
 8-Présentation_LAL_15_04_2021_elog.pptx9-Présentation_LAL_10_05_2021_elog.pptx10-Présentation_LAL_28_06_2021.pptx 
  42   Thu Oct 21 10:32:54 2021 BlancFixedinfoutilitiesOtherPresentationsHere the last part
of all the presentations since the beginning
of the project.
 12-Présentation_LAL_13_09_2021.pptx13-Présentation_LAL_27_09_2021.pptx14-Présentation_LAL_11_10_2021.pptxPrésentation_Amplitude_23_08_2021.pptx 
  64   Wed Jan 25 12:18:25 2023 BlancFixedinfolasers and opticsOptical roomPosition des miroirs et gain photodiodeNouvelle position des miroirs :

5.198865 ; 5.199305 ; -2.9 ; -2.9

Photodiode de transmission, gain
  
  21   Thu Sep 16 18:23:13 2021 BlancFixedinfolasers and opticsOptical roomPolarization Results in transmissionAfter data processing, I finally find the
polarization in transmissin of the FPC. As
you can see below, the polarisation is not
 Polarisation_transmission_cavité.png 
  17   Tue Sep 7 14:27:07 2021 BlancFixedinfolasers and opticsOptical roomPolarisation Results of the NKTI made many tests about polarization and
we can see some points thanks to the following
figures :
 Ellipsicité_NKT.PNGPolar_horizontale_fonction_pussance_NKT.PNGPolar_verticale_fonction_pussance_NKT.PNGPolarisation_Ag_VS_Diélec.PNG 
  19   Wed Sep 8 10:50:38 2021 BlancFixedinfolasers and opticsOptical roomPolarisation Results of the NKTTo have the polarisation, we must have
1 value because the laser in entry of the
system has 1 polar. Due to that, the graphe
 Tableau_polar.PNG 
  77   Thu Mar 2 11:42:19 2023 BlancFixedinfolasers and opticsOptical roomPolar cavitéAprès avoir locké avec la
lockline et retiré le glan et la paire
de lambda sur la voie PDH, j'ai observé
 Stokes_parameters_CAVITY.pngDOP_DOLP_DOCP_CAVITY.pngPhase_Ellipticité_Êta_CAVITY.pngEllipse_Polarization_CAVITY.png 
  78   Thu Mar 2 17:42:51 2023 BlancFixedinfolasers and opticsOptical roomPolar cavitéAprès avoir enlevé le PBS
en transmission de la cavité j'ai
cherché à atteindre le maximum
 Ellipse_Polarization_CAVITY.pngEllipse_Polarization_CAVITY_2.png 
  1   Tue Mar 23 18:33:16 2021 Ronic ChicheFixedinfolasers and optics | detectors and electronicsOptical roomPhase noise measurement of the Amplitude MIKANInstallation of the MIKAN.
powermeter (with OD1) just after the
oscillator shows 440mW for 4A of the MIKAN
  
  2   Tue Apr 6 09:25:47 2021 Ronic ChicheFixedinfolasers and optics | detectors and electronicsOptical roomPhase noise measurement of the Amplitude MIKANCoupling into a 50-50% fiber coupler using
the Thorlabs XYZ table NanoMax TS.
We reached 117mW after the 50% arm
  
  37   Wed Oct 20 14:54:00 2021 Ronic ChicheFixedinfolasers and optics | detectors and electronicsOptical roomPhase noise measurement of the Amplitude MIKANMIKAN phase noise and RIN measurements:




 MIKAN_optical_phase_noise_comparison_with_NKT_CW_oscillator_&_RIN_@54MHz.png 
  35   Tue Oct 19 18:27:20 2021 Ronic ChicheFixedreportmechanics | lasers and optics | detectors and electronicsOptical roomPZT resonant frequencieswe have excited the PZT with a swept sinus
wave from 1kHz to 10kHz and from 10kHz to
100kHz.
 Sweep_1kHz-10kHz.pngSweep_10kHz-100kHz.png 
  71   Mon Feb 6 16:51:51 2023 BlancFixedinfolasers and opticsOptical roomOptimisation de la polariation Tangor and LocklineJ'ai optimisé la polarisation
du Tangor et de la Lockline en jouant sur
l'angle du combiner et sur la lambda/2
 13x 
  65   Thu Jan 26 22:49:46 2023 BlancFixedinfolasers and opticsOptical roomNouvelles positions moteurs et calibrations cameraPositions moteurs :

5.198865 ; 5.198596 ; -2.9 ; -2.9

Calibration caméras :
 Lock_lockline.pngSignal_d'erreur_PDH.png 
  89   Fri May 26 18:08:27 2023 BlancFixedinfolasers and opticsOptical roomModulation EOMEOM dans la lockline:

Image 1 (sans 2è étage):
on voit la modulation en réflexion
 osc_preamp_AOM100_etage1_EOM.pngosc_preamp_AOM100_etage1_EOM_etage2.pngosc_preamp_AOM100_EOMbreadboard_matlab.pngosc_preamp_AOM100_EOMbreadboard.png 