HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Commissionning Commissionning Preparation Pannes ShiftCheck
  Toutes les notes concernant les Commissionning de ThomX, Page 15 of 59  Not logged in ThomX    logo
Entry   VM Entered by Super Team from 134.158.195.141 on Thu Dec 5 08:31:12 2024;  
08h28 Start ThomX

08h40 Some magnets remain switched off. Cycling was not performed

10h20 V is 'ON'
Entry   VC; Frequence anneau et systeme de synchro 
Rappel: 

la fréquence de l'anneau doit etre modifiée avec l'insterface RING RF cavity :

Ring RF doit etre divisible par 15 à 5 chiffres après la virgule (cela fait des pas de 150Hz sur le 500MHz)    c'est
Entry   SC, HG, VM; Passage à 61.5MeV et 70 MeV screenshot_steerers_linac_findejournée.pngBeam_transmission_Sole.png
9h14 Mise en chauffe

Pas de camera laser qui s'ouvre sur PlateformeIHM

9h19 cyclage aimants LI, TL sur interface
Entry   VC, Carlos Buitrago, Sudhanshu Thakur, ND; TP 29-11--2024 
demarrage chauffage 8H20

test nouveau code synchro 50Hz => ne fonctionne pas

Le nouveau code 25Hz ne fonctionne pas  => code installé 25Hz (juin 2024)
Entry   VM, IC, VK ;  
08h18 Start ThomX

10h00 HV is 'ON'

10h35 RF Gun phase is 174 dg. Section Phase is  209 dg. Sect. Att. is 2.70 dB TL/BPM2 X=0, Charge is -127 pC
Entry   VC; Shift summary 27/11 QP1_scan.pngQP2_scan.pngQP3_scan.png
8h : mise en chauffe (laser, modulateur, frigo, chiller, cyclage)

9H30 y'a eu une intervention non signalée dans les fosses toutes les rondes sont tombées! (Maher referme)
recette # operation_feedback_et_LE 20241126_17_43_31(faisceau non centré sur TL/QP.01)
Entry   MJ RC KD; shift du 26 novembre 2024 2024-11-26_12_22_06_el_dg_sst_01-ccd_01_RAW_1.png
8h : mise en chauffe en remote (laser, modulateur, frigo, chiller, cyclage)



10h48 : mise en route du feedback sur l'injection dans la section (1essai = erreur de signe sur le signal d'erreur), 2e essai (1min plus
Entry   KD, RC; shift du 22 novembre 2024 TL_BPM4_locked.dat
9h30 : mise en chauffe

intervention casemate pour alignement laser et nettoyage optique.

11h : démarrage, charge énergie max 100pC pour atténuateur à 330pas, phase 187°
Entry   KD; laser PC  2024-11-22_11_07_23_li_op_las_02_RAW.png2024-11-22_11_07_57_li_op_las_02_RAW.png
Mesure de ce matin et réalignement:

sortie laser : 298uJ

sortie ligne de transport : 209uJ
Entry   VM Entered by Super Team from 134.158.195.141 on Thu Nov 21 08:26:43 2024;  
08H25 Start ThomX

09H45 HV is 'ON'

09h49 Breakdown in the RF Gun
icon3.gif   MJ VC KD RC DN; Shift summary 19/11/2024 YAG_TL3_beam.pnginjection_ring.pngFluo_det.png
8h20 demarrage machine

iris 1.3mm
att 440
Entry   Entered by Nicolas Delerue from 134.158.195.144 on Fri Nov 15 12:13:26 2024; Charge excess in the TL Screenshot_from_2024-11-15_12-12-55.pngScreenshot_from_2024-11-15_12-12-46.png
By looking at the BPM transmission tool one can see that there is more charge on TL/BP.03 than on TL/BPM.02 (see attached image).

The BPM seetings have been checked and they are similar.

One can see a similar effect when comparing TL/ICT.01 and TL/ICT.02.
Entry   IC, VK, VM, ND; Ring studies, MRSV 36x
07h50 Start ThomX

09h20 HV is 'ON'

09h25 HV  1215 V
Entry   Entered by Viktor Soskov from 134.158.195.153 on Thu Nov 14 09:21:36 2024; Etat laser 
Bonjour, rien n'a change au faisceau laser (distribution reste le meme,l'energie sur la cathode =60mkJ, Iris = 1.3mm, Att =420).

J'ai termine les mesures. On peut demarrer.

Viktor.
Entry   Entered by Super Team from 134.158.195.141 on Thu Nov 14 08:33:03 2024;  15x
08h30 Start ThomX

10h00 HV is 'ON'

11h03 RF Gun phase 230 dg. Att. 0.0 dB, Laser Att. 360.00, Charge -145 pC, Section Att. 2.59 dB, Phase 207 dg.
Entry   VC; Shift summary 13/11/24 Q_transport_vs_Soleno.pngQ_transport_vs_Soleno_Align_917_1.pngQ_transport_vs_Soleno_Align_917_2.pngICT_Att_320_to_400.pngSPSum_LI_Att_320_to_400.png
demarrage machine 8h30
demarrage puissance RF
Phase charge max 286° Qmax 103pC sDev 13pC
Entry   Entered by Viktor Soskov from 134.158.195.153 on Tue Nov 12 10:36:24 2024; Salle laser ThomX 
Bonjour , l'intervention du Dalkia sur le CTA de la salle laser est terminee.

Viktor.
Entry   MJ KD VC; shift du 12 novembre 2024 
8h10 : mise en chauffe en remote (modulateur, laser, chillers).

redemarrage serveur camera UV
vide canon à sauté
Entry   IC, VK, JN; ring studies 13x
8h50 Start of the modumator and all subsystems

Beam studies.

Orbit Correction.
Entry   IC, VK, VM, JN;  6x
8h50 Start of the modumator and all subsystems

PC client 1 was frozen => we restarted

10h20 HV on 1215 V
ELOG V3.1.4-395e101