  Status of commissioning, report also here plots are reports., Page 16 of 24  Not logged in ELOG logo
ID Date Author Status Typedown Category Location Title Text Attachments
  224   Thu Jun 22 20:20:03 2023 Ronic ChicheFixedinfolasers and opticsThomX igloo33MHz oscillator + Alphanov amplifier lockwe checked yesterday morning the real input
power @ 30% for the amp => it is 16W in
agreement with the previously measured values
  
  225   Wed Jun 28 19:01:03 2023 Ronic ChicheFixedinfolasers and opticsThomX iglooFirst X rays and FP-cavity mode and electron beam waists size @ IPon friday 23/06 afternoon, after scanning
the hexapod z-axis, we observed a cut of
the power stored in the FP-cavity (with constant
 Raw_data.jpganalyse_profil_vert_X-1.pptx 
  227   Wed Jul 26 14:49:41 2023 Ronic ChicheFixedinfolasers and opticsThomX igloo33MHz oscillator + Alphanov amplifier lockToday, we locked the cavity with input
power @ 30% for the amp => we got 40kW
with only 30% of coupling (and a bad lock
  
  249   Thu Jul 27 18:47:57 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHzpour préparer le lock cavité-anneau,
j'ai un setup de lock en salle optique
entre le laser OneFive 133MHz et un synthé
  
  250   Fri Jul 28 13:19:22 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHz
régler le problème
1:
Kevin m'a apporté un déphaseur
 lock_anneau-cavite.pdf 
  251   Mon Jul 31 19:17:40 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHzToday, I installed a DB9-DB9 female-male
cable on the PZT connector of the FP-cavity.
the PZT is connected between pins
 CFP_-_piezo_intra_cavité.pdfImage_of_P4_S2_window_open_Oxidization_shown.jpeg 
  252   Wed Aug 2 11:38:20 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHzToday, I connected the BNC-DB9 female prolongator
cable to the FP-cavity PZT cable (DB9-DB9)
and to the channel B of the Laselock.
 FP-cavity_PZT_@0V.jpgFP-cavity_PZT_@10V.jpg 
  235   Tue Sep 5 18:08:39 2023 Ronic ChicheFixedinfolasers and opticsThomX iglooEquipments shutdownon the August 30rd and 31th, a global power
shutdown was forseen for ThomX.

to prevent damage on equipments,
  
  236   Tue Sep 5 18:21:12 2023 Ronic ChicheFixedinfolasers and opticsThomX iglooFP-cavity FSR shifttoday, to match the ring frequency at 500.25MHz
(15th laser harmonic), we did a frequency
shift on the laser using the Smaract motors
 20230905_173506.jpg 
  237   Wed Sep 6 19:57:48 2023 Ronic ChicheFixedinfolasers and optics | detectors and electronicsThomX iglooFast feedback loop between laser and FP cavitytoday, we tried to lock the FP cavity with
the Smaract motors ON (with option -LV).
we know the Smaract controllers produce
  
  238   Wed Sep 6 20:09:56 2023 Ronic ChicheFixedinfolasers and opticsThomX iglooSmaract controller remplacementpreviously, we were using a spare Smaract
MCS controller to drive the Onefive linear
stages (without -LV -low vibration-
  
  240   Thu Sep 7 19:23:36 2023 Ronic ChicheFixedinfolasers and optics | detectors and electronicsThomX iglooFast feedback loop between laser and FP cavitytoday, after the several unsuccessful attempt
yesterday to get an improvement in the lock,
we decided to "rebuild"
 20230907_182412.jpg20230907_182442.jpg 
  241   Fri Sep 8 12:43:04 2023 Ronic ChicheFixedinfomechanics | lasers and optics | detectors and electronicsThomX iglooRemoving high order modesthis morning we locked the laser and the
FP-cavity with ~ 40kW => some HOM appeared
"randomly" depending on the power.
  
  242   Fri Sep 8 18:22:21 2023 Ronic ChicheFixedinfomechanics | lasers and optics | detectors and electronicsThomX iglooRemoving high order modeshere is the picture of the L-shape arm
and the inside of the vessel.

this image corresponds to the "zero"
 Capture.PNG 
  253   Fri Sep 8 19:35:36 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHzthis afternoon, I installed the frequency
detection scheme in the bunker :

- I changed the large reflected
 20230908_190054.jpg 
  244   Fri Sep 8 19:45:56 2023 Ronic ChicheFixedinfolasers and opticsThomX igloo33MHz oscillator + Alphanov amplifier lockredoing the PDH error signal scheme with
discrete components is more flexible and
it is easier to check the signal/noise ratio.
  
  245   Tue Sep 12 14:28:36 2023 Ronic ChicheFixedinfomechanics | lasers and optics | detectors and electronicsThomX iglooRemoving high order modesyesterday with Daniele, we tried again
to move the arm horizontally and vertically
from the "zero position" to have
  
  254   Tue Sep 12 17:58:41 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHzthis afternoon, I tried to lock the FP-cavity
on a local 500MHz synthesizer as a frequency
reference
  
  255   Wed Sep 13 12:24:14 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHzthis morning, I added a Thorlabs lowpass
filter at 1kHz after the mixer and a resistor
at the Laselock output to the FP-cavity PZT.
 20230913_114202.jpg 
  256   Wed Sep 13 18:33:50 2023 Ronic ChicheFixedinfodetectors and electronicsOptical roomlock oscillateur 33MHz - synthé 500MHzthis afternoon, I firstly connected the
HV output of the Laselock to the FP-cavity
PZT : https://elog.lal.in2p3.fr/FPC/THOMX+commissioning/248
  