HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Commissionning Commissionning Preparation Pannes ShiftCheck
  Toutes les notes concernant les Commissionning de ThomX, Page 47 of 62  Not logged in ThomX    logo
ID Date Authordown Status Type Category Important Subject Icon
  1189   Fri Feb 6 08:26:41 2026 Entered by Super Team from 127.0.0.1 on Fri Feb 6 08:26:22 2026Under ProcessShift summaryRF D1   

08h25 Warm-up ThomX: Modulator, Laser, Fridge

08h33 Chillers were started, cycling all magnets.

09h31 HV is on. Vacuum: Li/Vac1 4e-9, Li/Vac2 3e-9, Li/Vac3 3e-9, Li/Vac4 1e-9

09h33 Sect. Att. 30 dB, RF Gun Att. 20 dB, HV 1030 V Interlock

09h39 Sect. Att. 30 dB, RF Gun Att. 20 dB, HV 1050 V Interlock. Something wrong

10h20 HV 1050 V. Maher is here. Interlock by reflected power to the klystron.

10h26 Modulator is on standby.

10h29 HV is on W/O RF. HV 1215 V. All is OK.

10h34 Modulator is on standby.

10h57 HV is on, 1030 V

11h09 HV is  1050 V

11h35 50pps, 1030V

11h42 1040 V interlock

11h45 Modulator is on standby.

16h10 Stop ThomX

 

Attachment 1: Screenshot_from_2026-02-06_10-52-58.png
Screenshot_from_2026-02-06_10-52-58.png
  Draft   Fri Apr 24 08:05:11 2026 Entered by Super Team from 127.0.0.1 on Fri Apr 24 08:05:02 2026    , entered from 127.0.0.1 

8h00 : mise en chauffe en remote (frigo/chillers, laser, modulateur, cyclage)

  24   Tue Jun 8 17:40:20 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 17:40:07 2021FixedShift summaryresumes Résumé de la journée 

- Pour les atténuateurs : les butées ont été trouvées, ATT02-MOT01 c'est la canon, ATT01-MOT01 c'est la section.

- Des difficultés ont été rencontrés avec le modulateur : Interlock à cause de l'eau, interlock alim HT, reboot modulateur et vérification de l'autorisation de tir MPS faite.

Le modulateur fonctionne maintenant sans problèmes à une tension de 1240V et un vide klystron de 1.2 uA qui devrait diminuer par la suite. Les mesures radioprotection ont été faites

- Pour le MPS, cliquez sur Paramètres en bas de l'écran principal puis vérifier que LINAC est on.

Pour demain :

- Démarrer régulation eau en plus du modulateur

- Vérifier les signaux RFs sur oscillo et Réglage des retards (demarrage_delays)

- Ne pas mettre beaucoup de puissance, vérifier la chaine RF et vérifier les atténuateurs

- Vérifier caméra et ICT

  23   Tue Jun 8 17:30:12 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 17:29:26 2021FixedInfoetc   

Capture ecran modulateur

Attachment 1: HT_1100.png
HT_1100.png
  22   Tue Jun 8 17:27:35 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 17:27:21 2021Under ProcessInfoPrise de donnees HT sur modulateur et radioprotection 

Contrôle radioprotection en cours HT = 1240V tension max, vide klystron : 1.2 uA

 

  21   Tue Jun 8 17:16:10 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 17:15:58 2021FixedInfoetc   

Modulateur OK, HT = 500 V en trig

  20   Tue Jun 8 17:04:44 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 17:04:28 2021FixedInfoetc Hv sur modulateur 

Sur le MPS, Vérifiez qu'on est bien en PARAMETRES/ Linac pour autorisation HV sur modulateur

  19   Tue Jun 8 15:58:08 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 15:57:55 2021Under ProcessInfoetc   

Modulateur remis en chauffe car interlock

  18   Tue Jun 8 15:06:12 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 15:05:59 2021FixedInfoetc   

ATT02-MOT01 attenuateur canon en butée à -8 jusque 3329

  17   Tue Jun 8 15:05:04 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 14:49:35 2021FixedInfoetc attenuateur section tests butée moteur 

ATT01-MOT01 atténuateur section course de -870 step à 2485 pour les butées

  16   Tue Jun 8 14:49:12 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 14:48:07 2021FixedInfodocs   

LI/HFI/ATT.02-MOT.01 Attenuateur Canon

  15   Tue Jun 8 14:44:01 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 14:43:48 2021Under ProcessOtheretc attenuateur section tests butée moteur 

Pas complètement au switch à 0.0 pas pour LI/HFI/ATT.02-MOT01

  14   Tue Jun 8 14:42:30 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 14:42:17 2021Under ProcessQuestionetc   

Attenuateur LI/HFI/ATT.02-MOT01 en butée à 3329

  13   Tue Jun 8 14:39:20 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 14:39:06 2021Under ProcessOtheretc attenuateur section tests butée moteur 

Tests des moteurs sur atténuateur en cours

Repérage des butées et des positions

  12   Tue Jun 8 14:36:48 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 14:36:35 2021Under ProcessProblemetc Tests RFs 

Interlock eau sur modulateur, arrêt du modulateur.

Remise en route

A nouveau interlock modulateur, purge de l'eau

Remise en chauffe modulateur ok

Attachment 1: mise_en_chauffe
  11   Tue Jun 8 12:39:23 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 12:39:09 2021Under ProcessShift summaryetc summary du matin 

Bonjour,

la synchro est effective

le modulateur est pret

L'oscillo est opérationnel

rdv à 13h30-45 pour la ronde

A+

Christelle

  10   Tue Jun 8 11:49:13 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 11:48:58 2021Under ProcessFixproblemes attenuateur section tests butée moteur 

On monte progressivement le moteur de l'atténuateur de la section pour trouver la butée supérieure  li/hfi/att.01-mot.01

Le déplacement du moteur est lent 

On constate un problème à régler dans le DS CALC de calibration  calc/li_hfi/write_att.01-mot.01 --> Hayg bosse dessus

butée positive à 1500

butée négative à 0

les atk se sont figés et ne répondent plus --> problème fenetre d'erreur non visible --> ticket glpi sur le sujet pour configurer jive pour avoir la fenetre d'erreur sur 'application jive et non ailleurs

Mail envoyé à Mohamed pour savoir à quelles valeurs correspondent les butées.

Les butées sont réglées de la même facon pour le canon

reste à savoir si la position 0 correspond au zero d'atténuation ?

 

  9   Tue Jun 8 10:58:29 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 10:58:16 2021Under ProcessInfoetc Signaux RFs 

Mise en place des signaux Rfs sur l'oscilloscope de la salle CC, Travail sur le timing en cours.

Valeurs Redpitaya pour signaux RFs : Trigger source = 6 (Trigger EXT), Trigger Delay = 8200, Trigger level = 0.1

  8   Tue Jun 8 10:40:54 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 10:40:40 2021FixedInfoetc Fermeture sous-sols et toit casemate 

Les sous-sols et le toit sont maintenant fermés

  7   Tue Jun 8 09:31:28 2021 Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 09:31:12 2021Under ProcessInfoetc Tests RFs 

Aujourd'hui, démarrage des tests RFs.

Vérification du bon fonctionnement des IHMs, mise en route du MPS et fermeture casemate en fin de matinée

 

 

ELOG V3.1.4-395e101