11h24 Energy = 50 MeV, Laser Phase 100 dg., Sect. Phase 223 dg., Sect. Att. 2.38 dB, I_Gun -79.2489 pC, I_Linac -115.1205 pC, I_TL -82.446 pC RF_Ampl. 44.5956 kV, RF_Phase -38 dg.

11h34 Energy = 50 MeV, Laser Phase 100 dg., Sect. Phase 223 dg., Sect. Att. 2.38 dB, I_Gun -80.0998 pC, I_Linac -115.3244 pC, I_TL -82.2752 pC RF_Ampl. 99.1184 kV, RF_Phase -38 dg.


12h09 Energy = 50 MeV, Laser Phase 102 dg., Sect. Phase 223 dg., Sect. Att. 2.39 dB, I_Gun -102.3736 pC, I_Linac -136.5331 pC, I_TL -104.5544 pC RF_Ampl. 99.1184 kV, RF_Phase -38 dg.

12h11 Laser Att. 410, Energy = 50 MeV, Laser Phase 102 dg., Sect. Phase 223 dg., Sect. Att. 2.39 dB, I_Gun -200.2588 pC, I_Linac -233.6895 pC, I_TL -201.9032 pC RF_Ampl. 99.1184 kV, RF_Phase -38 dg.

We checked the max charge from the gun it is 200 pC. The charge in the ring increased linearly when going from 100 to 200 pC in the linac:

Stop ThomX.

Afternoon will be dedicated for openning the valve in te FPC
 

 