VK, IC. VM, LS; Work on the new optics
|
9h30 Start of the modulator and laser
Start of the beam. Problem with charge, the max charge at the end of the TL 60 pC. We can not increase it by the attenuator. To be understood.
Corrector ri-c2/ps/str.03-h.01 does not work => problem to control and tune the orbit. JNC will look |
IC, VM; Work on orbit at 70 MeV for X rays    
|
7h20: mise en chauffe en remote (frigo/chillers, laser, modulateur, cyclage)
08h55 HV is ON
10h07 70 MeV. Beam is in the ring with RF 100 kV, phase -37.5 dg. The recipe_recipe_LI_TL_RI_good_20260318_16_17_14.txt loaded, linac steerers |
Entered by Nicolas Delerue from 80.119.21.73 on Mon Jan 10 22:14:00 2022; WAC reset
|
| Les wavecatchers ont été réinitialisés pour qu'ils se déclenchent correctement. |
Entered by Super Team from 134.158.195.142 on Tue Oct 18 17:39:43 2022; Voyant rouge en salle Laser
|
Voyant apparu vers 17h
SPR est passé voir : peut-etre en lien avec la clim
ce serait la centrale de traitement d'air dont le premier filtre est encrassé. Voyant rouge sur la CTA. |
Entered by Hayg Guler from 134.158.195.141 on Mon Oct 4 19:19:08 2021; Vide pendant la prise de données
|
| |
Entered by Moutardier from 134.158.76.123 on Tue Dec 1 09:56:35 2020; Verrification pour le démarrage a blanc
|
Verification de l'état de la Synchro : OK, tout les signaux sont en trigger externe.
Verification de l'état des diagnostiques :
- Libera 3 : n'est pas encore cofiguré (pas génant pour le démarrage a blanc) |
ND; Verifications IHM_cyclage
|
9:00 Accès pour FPC
Recherche des problemes de plantage de l'IHM cyclage.
Plantages difficiles a reproduire (pas de plantage quand j'essaie). |
Entered by Nicolas Delerue from 134.158.89.243 on Thu Jul 1 10:03:48 2021; Veni vedi exit
|
Sommes venus pour la reunion SST (ecrans) .
Personne en salle de controle.
Sommes repartis... Appelez nous dans notre bureau quand vous etes prets. |
Entered by sophie chance from 134.158.195.142 on Tue Oct 12 16:01:27 2021; Valeurs transport linac pour tests radioprotection
|
Attenuation canon : 2 dB car des claquages sont apparus lors de l'augmentation de l'intensité dans les solénoïdes, mesure
à l'oscillo Pic = 140 mV environ --> 77 MV/m
Phase canon = 40 degres energie max pour le transport |
Entered by Marie Jacquet from 134.158.89.45 on Tue Oct 11 11:09:03 2022; Valeurs des BPM LI et TL_1 surestimees ?
|
Ci-jointes des donnees BPM et YAG LI et TL_1, prise le 20/06 puis le 06/10, en fonction de valeurs des steerers 1 (pour LI) et 3 (pour TL)
--> Les valeurs mesurees au BPM ont l'air surestimees d'environ 30%. |
Entered by Super Team from 127.0.0.1 on Tue Jun 23 09:43:18 2026; Vaccum in the FPC
|
09h00 Start-up modulator, laser, fridge, chillers
After discussion with Daniele
Goal/Priority: Check for leakage in the FPC |
VK, IC. AL; Understanding of the shift in RF frequency 18x
|
8:40 Start warming up, problem with PSS. It was restarted.
Problems to start and tune the RF cavity. A clear working procedure and reliable tuning should b defined to optimize the Ring comissioning progress.
Feedback for teh RF has the suspicious behavior. At motor position close to the nominal, the feedback ofsets the motor in the negative direction |
MJ HG KD VC; URGENT SST off  
|
Camera SST inutilisable en debut de shift. IL FAUT ABSOLUMENT ARRETER de faire des trucs sur les cameras entre 2 shifts ! je n'ai
pas les competences pour remettre les sst en marche. Les boutons n'y font rien;
Nicolas peux-tu agir pour qu'on puisse commencer le shift. Merci |
HG/CB/KD; Twiss = F(Solé)
|
Phase de Q max : 195, on decale de -50 degrés
IRIS :0.7 mm, att 400, charge 100 pC --> laser sauvé, sigma x,y rms 0.21 mm
coil2 betax0 betay0 alphax0 alphay 0 |
Entered by mohamed el khaldi from 134.158.76.146 on Fri Sep 17 09:12:06 2021; Tuning des HOM's de la cavité RF anneau en stand by aprés les coupures d'électricité
|
le tuning automatique des HOM's de la cavité RF anneau fonctionnait bien avant les coupures d'éléctricité.
à mon retour des vacances je voulais reprendre les tests mais en vain
deux hypothéses se présentent: |
Entered by Moutardier Alexandre from 134.158.195.144 on Fri Nov 19 09:24:11 2021; Trou dangereux !!!
|
Ce matin en verifiant les orientations des jauges dans l'anneau pour faire des simulations correcte j'ai du entrer dans l'anneau.
En resortant je suis pris les pieds dans le trou sous l'escalier (cf photo) et j'ai failli tomber !!!
Ce trou est extrement dangereur car dans le passage a un endroit ou l'on voit dificilement nos pied. Il faudrait le reboucher |
MJ; Trends - conditionnement section 23 juillet
|
| Je viens de sauvegarder les trends conditionnement d'aujourd hui dans data/shared du jour |
Entered by Super Team from 134.158.195.142 on Mon Oct 11 13:45:53 2021; Travaux
|
Travaux en cours à l'extérieur, le goudron sur le chemin a été enlevé, une pelleteuse bloque le passage vers ThomX,
le passage est possible mais difficile |
Entered by HG/JNC/SC from 134.158.195.142 on Thu Mar 17 15:27:21 2022; Transport faisceau 
|
Modulateur en marche
Transport faisceau jusqu'à TL/DG/SST.01
Charge = 55 pC, Energie laser non mesurée aujourd'hui |
Entered by Super Team from 134.158.195.142 on Thu Nov 25 10:52:12 2021; Transport
|
Optimisation charge et transport. Charge 100 pC ok.
Optimisation phase canon faite
Optimisation phase section en cours |