  Status of commissioning, report also here plots are reports., Page 19 of 24  Not logged in ELOG logo
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 
 




Manar
Amer wrote:



Today: Manar, Ronic and Aurlien started the study of the beam profile
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 6x
Adding the fitted beam in 1D in Horizontal and vertical axis.

for 10%   to  60%




Manar
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 
Today a second reading of the beam profile was done , with Victor ,Ronic, Aurlien and Manar

an additional set-up was made using two 4 deg wedges instead of High reflecting (HR) and Anti-reflecting (AR) mirrors.

Two reading were taken:
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 9x
Readings of the beam shape and horizontal (upper plot) and vertical (lower plot) axis fit at the direct output of the amplifier.

The beam shape relatively shaped like an egg.




Manar
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 20220401_Alphanov_Beam_setup_after_compressor.jpg20220401_Amplifier_AfterCompressor_50perc_133MHz.bmp20220401_Amplifier_AfterCompressor_60perc_133MHz.bmp20220401_Amplifier_AfterCompressor_50perc_133MHz_BeamFit.png20220401_Amplifier_AfterCompressor_60perc_133MHz_BeamFit.png
Readings of the beam shape and fit at the output of the compressor

differance from previous reading is that here we used wedges instead of HR mirrors.

Similar to previous readings, the beam shape deforms and the Gaussian fit is bad after 50% amplification
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 6x
Adding the readings  20% , 30% ,  40%  for output of amplifier after the compressor

 




Manar
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 12x
This Morning, another reading was taken for the output of the amplifier after the compressor using 2 wedge mirrors.

In addition, a start of the calibration of a PulseCheck "Autocorrelator" to measure the pulse duration. 

note, the pulsed laser used is OneFive 133.33 MHz
Entry   Alphanov amplifier Beam Pulse Duration, posted by Manar Amer at ThomX igloo about lasers and optics pulse-check_compressed.pdf
The pulse duration from the amplifier compressor output will be measured using PulseCheck autocorelator

a first alignment of the device was done, continuation in the afternoon.

YouTube link attached of the general operation of pulse check < 5 min :  https://www.youtube.com/watch?v=J1pNHYySSYg
    Reply   Alphanov amplifier Beam Pulse Duration, posted by Manar Amer at ThomX igloo about lasers and optics 20220401_Alphanov_Pulse_Duration.jpg20220408_AMplifier_133MHz_Pulse_duration.jpg20220408_AMplifier_133MHz_Pulse_duration_better_alignment.jpg
Measurement of the pulse was done at the end of the afternoon, Pulse Duration FWHM = 12.9 ps

After a long process of adjusting the alignment and angle of the crystal inside the device

The power input on the PulseCheck device should be above the sensitivity, in our case we had 1 mW input.
    Reply   Alphanov amplifier Beam Pulse Duration, posted by Manar Amer at ThomX igloo about lasers and optics 
Pulse Duration FWHM = 12.9 ps




Manar
Amer wrote:



Measurement of the pulse was done at the end of the afternoon, Pulse
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 20x
Victor, Ronic, Manar

Today  was dedicated to the study of the CVBG, and it's effect on the beam profile

we opened the box containing the 2 CVBGs : The 2CVBG are glued from the bottom on a copper surface .
    Reply   Alphanov amplifier Beam Profile, posted by Manar Amer at ThomX igloo about lasers and optics 8x
For better comparison ,

the measurements done previously with 2 CVBGs was done at ~ 30 cm and the one done on Friday was for 1 CVBG is at 1 m

so we did additional measurement for 2 CVBGs at 1 m, for 20 , 50 and 70 % amplification 
Entry   Alphanov amplifier beam profile Data , posted by Manar Amer at ThomX igloo about lasers and optics | detectors and electronics 8x
Adding the schematic of the measurements.,

the 4° Beam Deviation, AR Coating ( B coating)

The 3 data points taken of the beam profile are fitted in Gaussian Beam with taking the beam waist at the output of the compressor box.
    Reply   Alphanov amplifier beam profile Data , posted by Manar Amer at ThomX igloo about lasers and optics | detectors and electronics 
This Morning with Victor the amplifier was turned on @ 20% amplification (output ~ 9 W ) for approximately 3 hours and no error appeared.

I took data of the beam profile at different points without a lens after the 2 wedges 

@ 0% (only pump beam), output ~ 300 mW (taken from previous data) , output after 2 wedges 2.2 uW  
Entry   Amplifier Beam Profile over time , posted by Manar Amer at ThomX igloo about lasers and optics | detectors and electronics comparision_Between_Beam_profile_over_time.jpg
This morning, with Ronic, we opened the compressor box to observe if there is any misalignment of the mounts or the CVBG's

a comparison slide between the Beam Profile over time and measurements we have taken, is included.

 

we noticed
today that the images need a rotation, and I took the assumption we did not rotate last year and did the rotation of the previous images.

Comparing
    Reply   Amplifier Beam Profile over time , posted by Manar Amer at ThomX igloo about lasers and optics | detectors and electronics 10x
This morning we took data of the beam profile at 4 different points to see the evolution of


the beam shape
divergence


over distance for all amplification percentages

Data plotted for the distance vs radius for all and divergence in rad is extracted and plotted as a variation of amplification power.
    Reply   Amplifier Beam Profile over time , posted by Manar Amer at ThomX igloo about lasers and optics | detectors and electronics 
Information about today's work is added to logBook !!




Manar
Amer wrote:



This morning we took data of the beam profile at 4 different points
Entry   New Mirrors from LMA _ Images, posted by Manar Amer at Optical room about lasers and optics 20230317_Images_of_New_Mirrors-compressed.pptxMirror_Tested.jpgWhatsApp_Image_2023-03-17_at_6.39.44_PM.jpgimage006.jpg
Today we tested a mirror from one patch

image is for the front face of the mirror

PowerPoint has more details about the images
Entry   Cavity Alighnment , posted by Manar Amer at ThomX igloo about lasers and optics | detectors and electronics 9x
Last week, with Ronic and Victor we aligned the cavity using CW laser (Koheras)


we have also installed 4 mirrors in the cavity with the best theoretical qualities (serial number and images included)

The
Plan ULE mirror P4 thickness was not compatible with the piezoelectric mount. We had to install a metal spacer behind the mirror
    Reply   Cavity Alighnment , posted by Manar Amer at ThomX igloo about lasers and optics | vacuum | detectors and electronics 20230404_P4_Transmission.jpg20230404_vacuum_level.jpg
Today, we prepared lenses for a telescope for the CW laser injection into the cavity, yet to be installed

Image of the transmission at P4 attached, an estimation of the beam size of the mode see is ~ 5.5 mm 

The vacuum in the 2 optical cavities is decreasing but slowly. today it is 2.6 - 2.4 * 10^-7 mbar