  1214   Wed Mar 18 07:58:19 2026 KD, VM, MJ, RC, DNUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 18 mars 2026 

8h: mise en chauffe en remote (frigo/chillers, laser, modulateur, cyclage)

*** Programme : Mesure spectre et monochromateur à 61.5MeV (70MeV si le temps le permet)

61.5 MeV

09h35 HV is on
photocathod laser phase 62 dg.  The receipt 61p5MeV_20250703_12_56_55.txt loaded, going to 61.5 MeV (interlocks)
10h13 Beam is on TL/SST02. Sect. att. 0.992 dB, sect. phase 236 dg.
10h30 Aligned with QP1 - QP3, linac steerers: H [-0.2 -3.02], V [-2.55 3.22]
11h05 Beam is in the ring W/O RF with all ring correctors set to zero

RF 100 kV storage is good, but can't correct the orbit  at 61.5 MeV :  le faisceau est presque hors du tube ==> Try to go to 70 MeV

70 MeV

13h20 RF processing the section on 25 pps by increasing pulse length from 1 us to 3 us
13h56 70 MeV, Linac steerers H [0.21 -3.75], V [-2.84 3.33], sect. att 0.18, phase 255 dg. laser phase 56 dg. (On the base of 70_MeV_Vert_tune 0.66_good_20251212_13_56_38.txt)
16h17 recipe_recipe_LI_TL_RI_good_20260318_16_17_14.txt saved, screenshots, RF 100 kV, phase -36 dg., Freq. 500.031645 MHz

L'orbite n'est pas la meme que pour 50 MeV  ==> Checks spectres dromadaires a V+40 

X_fpc = -1.5 / -1.3 / -1.7 / -1.9 / -1.1  mais on a oublie d'ajuster la phase a chaque fois  .... meme phase (3.0 V) 
X_fpc = -0.9 / -0.7 / -0.4 / -0.2 / -0.5  en ajustant la phase a chaque fois
Cf les 2 screenshots "Spectre 70 MeV"

On se place a X_fpc = -1 mm (pas top mais dans l'urgence on se met la)

Fente2 centrees a l'oeil : [H , V] = [11 , -23]
Prise de spectres a +/- 10 en H et V  (a voir ce que ca donne offline)

17h56 ThomX was stopped

Attachment 1: Screenshot_from_2026-03-18_17-43-17.png
Screenshot_from_2026-03-18_17-43-17.png
Attachment 2: Screenshot_from_2026-03-18_17-32-49.png
Screenshot_from_2026-03-18_17-32-49.png
Attachment 3: Screenshot_from_2026-03-18_17-32-38.png
Screenshot_from_2026-03-18_17-32-38.png
Attachment 4: Screenshot_from_2026-03-18_16-11-25.png
Screenshot_from_2026-03-18_16-11-25.png
Attachment 5: Orbite_2026-03-18_16-10-25.png
Orbite_2026-03-18_16-10-25.png
Attachment 6: Screenshot_from_2026-03-18_17-45-25.png
Screenshot_from_2026-03-18_17-45-25.png
Attachment 7: spectres_70_MeV.png
spectres_70_MeV.png
Attachment 8: spectres_70_MeV_2.png
spectres_70_MeV_2.png
  Draft   Tue Mar 18 07:56:38 2025 KD, IC, RC, DN, VMUnder ProcessShift summaryLaser | Opt | Linac Commissionning | Ring Commissioning shift du 18 mars 2025 - Mesure tailles transverses H et V de la source 

7h55: mise en chauffe en remote (modulateur, laser, frigo/chiller, cyclage)

*** programme ***
     - préparation de la machine pour la seconde session d'imagerie (du 19 au 21 mars)
     - mesure et optimisation de la longueur de paquet dans le linac

-----------------------------------------------------------------------------

09h20 HV is 'ON'
09h30 RF gun phase is 10 dg., Sect Phase is 209 dg. Sect Att. is 2.57 dB, Charges: -107 pC
09h45 the modulator was set to the standby mode. Access to the bunker

Mesures X-rays in X-Hutch

 ** Verification Photonic Science avec le cable "Soleil" : ok

 ** Mesures tailles transverses source (H et V):
      Fermeture partielle des fentes 1
      Det Photonic sur bras detecteur (a 280 mm du zero hexapode)
      Prise d'images des bords de la fentes (a differents voltages cavite RF, de 50 a 280 kV)

19h10 Stop ThomX

Attachment 1: Screenshot_from_2025-03-18_18-04-13.png
Screenshot_from_2025-03-18_18-04-13.png
Attachment 2: Screenshot_from_2025-03-18_16-50-47.png
Screenshot_from_2025-03-18_16-50-47.png
Attachment 3: closed_orbit_18032025.png
closed_orbit_18032025.png
Attachment 4: closed_orbit_woCOR_18032025.png
closed_orbit_woCOR_18032025.png
Attachment 5: 2025-03-18_17_38_46_OBL_DG_MRSV_01-CCD_01_RAW.png
2025-03-18_17_38_46_OBL_DG_MRSV_01-CCD_01_RAW.png
  1104   Fri Jul 18 08:49:22 2025 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 18 juillet 2025 

8h50 : mise en chauffe de la machine (frigo/chiller, laser, modulateur, cyclage)

  1194   Wed Feb 18 07:40:44 2026 KDUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 18 février 2026 

7h40: mise en chauffe en remote (frigo/chiller, modulateur, laser, cyclage)

8h40 HV ON

10h20 recipe_recipe_LI_TL_RI_all_20260218_10_18_05.txt saved ,

15h15 Li/ps/str03-V steers the beam verticaly "-" UP, "+" Down. Li/ps/str03-H steers the beam horizontaly, "+" <==, "-" ==>
16h44 Laser new position : [5.112, 4.423]

Align QP-Linac
Quad scans : depends on camera settings ...

Sole Emit_X betaX AlphaX Emit_Y BetaY AlphaY Camera Sole0 File Charge (pC) retard rem
230 1.31 13.8 -5.01 1.31 4.1 -1.5 0dB 66.47 Scan_QP0117h01.txt 110 10% check energy
235 1.57 11 -3.15 2.02 7.4 -2     Scan_QP0117h12.txt 110 10%  
240 2.61 11.7 -2.83 5.52 10.6 -2.7     Scan_QP0117h16.txt 110 10%  
245 2.06 46.9 -9.49 12.3 19.8 -3.98     Scan_QP0117h21.txt 110 10%  
230 1.29 7 -2.5 1.23 8.5 -2.5   0 Scan_QP0117h27.txt 110 10%  
230 1.65 12.1 -4.46 1.26 4 -1.58   100 Scan_QP0117h32.txt 110 10%  
250 11.61 39.3 -6.82 23.7 30.3 -4.53     Scan_QP0117h40.txt 110 10%  
242 2.3 28.4 -5.82 6.7 20.8 -4.26     Scan_QP0117h48.txt 110 10%  
241 1.99 21.3 -4.49 5.34 14.7 -3.14     Scan_QP0117h52.txt 110 10%  
238 1.57 12.1 -2.8 2.32 16.7 -4.21     Scan_QP0117h57.txt 110 10%  
243 3.63 18.4 -3.64 9.31 18.6 -4.09     Scan_QP0118h01.txt   10%  
230 2.41 25.2 -7.37 2.2 9.3 -3.24     Scan_QP0118h31.txt 230 350 check energy
242 3.51 15.1 -3.15 5.28 20.2 -4.63     Scan_QP0118h43.txt 110 350 check energy
245 5.85 16.7 -3.51 9.21 23 -4.64     Scan_QP0118h55.txt 110 350 check energy
248 20.5 20 -2.85 35 14.7 -2.4     Scan_QP0119h05.txt   350 check energy

Matching from calculated twiss in attached file.  

19:10 : End

Attachment 1: Quads_settings_after_match.md
# results 


twiss_sol_238A = [238,	1.57,	12.1,	-2.8,	2.32,	16.7,	-4.21]
501.195567934739
--------------------------------------------------
QP1L: -0.571358 [1/m^2]  	: -0.199962 [A]
QP2L: 10.641153 [1/m^2]  	: 3.724162 [A]
QP3L: -10.152380 [1/m^2]  	: -3.553103 [A]
QP4L: 6.461255 [1/m^2]  	: 2.261293 [A]
QP5L: 5.038224 [1/m^2]  	: 1.763264 [A]
QP6L: -10.700303 [1/m^2]  	: -3.744863 [A]
QP7L: 11.202321 [1/m^2]  	: 3.920559 [A]
--------------------------------------------------

twiss_sol_241A = [241,	1.99,	21.3,	-4.49,	5.34,	14.7,	-3.14]
212.779196267011
--------------------------------------------------
QP1L: -0.676645 [1/m^2]  	: -0.236810 [A]
QP2L: 10.589814 [1/m^2]  	: 3.706195 [A]
QP3L: -10.037038 [1/m^2]  	: -3.512736 [A]
QP4L: 6.543804 [1/m^2]  	: 2.290183 [A]
QP5L: 4.594024 [1/m^2]  	: 1.607804 [A]
QP6L: -10.602366 [1/m^2]  	: -3.710588 [A]
QP7L: 11.029235 [1/m^2]  	: 3.859982 [A]
--------------------------------------------------

twiss_sol_242A = [242,	2.3,	28.4,	-5.82,	6.7,	20.8,	-4.26]
16.3756129570483
--------------------------------------------------
QP1L: -0.678931 [1/m^2]  	: -0.237610 [A]
QP2L: 10.626355 [1/m^2]  	: 3.718983 [A]
QP3L: -10.001212 [1/m^2]  	: -3.500198 [A]
QP4L: 6.097615 [1/m^2]  	: 2.134027 [A]
QP5L: 5.211973 [1/m^2]  	: 1.824073 [A]
QP6L: -10.599792 [1/m^2]  	: -3.709687 [A]
QP7L: 10.926141 [1/m^2]  	: 3.823902 [A]
--------------------------------------------------

twiss_sol_243A = [243,	3.63,	18.4,	-3.64,	9.31,	18.6,	-4.09]
213.7927216092
--------------------------------------------------
QP1L: -1.332854 [1/m^2]  	: -0.466469 [A]
QP2L: 11.117187 [1/m^2]  	: 3.890763 [A]
QP3L: -10.018546 [1/m^2]  	: -3.506264 [A]
QP4L: 6.529993 [1/m^2]  	: 2.285350 [A]
QP5L: 4.802777 [1/m^2]  	: 1.680863 [A]
QP6L: -10.598775 [1/m^2]  	: -3.709331 [A]
QP7L: 11.006478 [1/m^2]  	: 3.852018 [A]
--------------------------------------------------

twiss_sol_245A = [245,	2.06,	46.9,	-9.49,	12.3,	19.8,	-3.98]
16.2164771100199
--------------------------------------------------
QP1L: -0.034446 [1/m^2]  	: -0.012055 [A]
QP2L: 9.847129 [1/m^2]  	: 3.446272 [A]
QP3L: -9.925618 [1/m^2]  	: -3.473741 [A]
QP4L: 6.561442 [1/m^2]  	: 2.296356 [A]
QP5L: 4.364315 [1/m^2]  	: 1.527411 [A]
QP6L: -10.231645 [1/m^2]  	: -3.580844 [A]
QP7L: 10.300960 [1/m^2]  	: 3.605102 [A]
--------------------------------------------------

twiss_sol_250A = [250,  11.61,	39.3,	-6.82,	23.7,	30.3,	-4.53]
3.98731082591887e-25
--------------------------------------------------
QP1L: -0.608052 [1/m^2]  	: -0.212804 [A]
QP2L: 10.306778 [1/m^2]  	: 3.607139 [A]
QP3L: -9.771682 [1/m^2]  	: -3.419867 [A]
QP4L: 5.967327 [1/m^2]  	: 2.088429 [A]
QP5L: 5.730826 [1/m^2]  	: 2.005659 [A]
QP6L: -10.333723 [1/m^2]  	: -3.616569 [A]
QP7L: 10.187679 [1/m^2]  	: 3.565457 [A]
--------------------------------------------------

## 230A with 230 pC beam charge 
twiss_sol_230A = [230,	2.41,	25.2,	-7.37,	2.2, 	9.3,	-3.24]
145.837228842677
--------------------------------------------------
QP1L: 1.235475 [1/m^2]  	: 0.432388 [A]
QP2L: 9.136295 [1/m^2]  	: 3.197496 [A]
QP3L: -10.228027 [1/m^2]  	: -3.579578 [A]
QP4L: 6.452841 [1/m^2]  	: 2.258348 [A]
QP5L: 4.641590 [1/m^2]  	: 1.624451 [A]
QP6L: -10.595351 [1/m^2]  	: -3.708133 [A]
QP7L: 11.006418 [1/m^2]  	: 3.851997 [A]

twiss_sol_242AN = [242,	3.51,	15.1,	-3.15,	5.28,	20.2,	-4.63]
285.154176153533
--------------------------------------------------
QP1L: -1.846704 [1/m^2]  	: -0.646304 [A]
QP2L: 11.594649 [1/m^2]  	: 4.057864 [A]
QP3L: -10.034874 [1/m^2]  	: -3.511978 [A]
QP4L: 6.563675 [1/m^2]  	: 2.297137 [A]
QP5L: 4.874020 [1/m^2]  	: 1.705797 [A]
QP6L: -10.616160 [1/m^2]  	: -3.715415 [A]
QP7L: 11.041865 [1/m^2]  	: 3.864402 [A]
--------------------------------------------------
  592   Mon Oct 17 09:09:13 2022 KD, MJFixedShift summaryLI | TL | LE | Linac Commissionning shift du 17 octobre 2022 

Redémarrage ThomX :

     * remise en pression d'eau sur la boucle principale (légèrement inférieur à 4bars à l'arret).

     * PSS HS (écran freezé) ==> rémarrage de l'écran de l'automate (nécessite la clé de l'armoire)

     * mise en chauffe du modulateur (9h)

 

Programme journée :

   * essaie d'alignement automatique (laser photoCathode + quad)

   * génération d'une recette pour injection dans l'anneau (mesure émittance + énergie)

   * Tests correction orbite TL

 

*********

* L'alignement automatique du laser sur la PhotoCathode semble fonctionner mais est très bruité dû au bruit sur les BPM (~1mm en X)

De plus il y a une saturation sur les BPM (LI et TL/BPM.01 au moins), cf. Screenshot ==> cela doit destabiliser l'alignement automatique.

* Alignement Steerer VS QP, même constat que pour la photocathode. Le bruit des BPM limite la résolution de l'algorithme

* Mesure Alignement QP de la TL ==> manque données BPM pour TL/BPM.04 (mean, std des positions)

 

Attachment 1: Screenshot_from_2022-10-17_15-25-06.png
Screenshot_from_2022-10-17_15-25-06.png
  1103   Thu Jul 17 08:08:41 2025 KDUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 17 juillet 2025 

8h05 : mise en chauffe en remote (modulateur, laser, frigo/chiller, cyclage)

 

*** Programme ***

- prise de spectre fluorescence (échantillon prostate) et amélioration du setup (réduction du bruit de fond)

==> Fait, montage avec du plomb meilleur et faisceau collimé dans le cone en plomb

- mise en place de la diode Calibrée "sans" bruit (écran alu)

==> pas eu le temps de progresser sur ce point

  1193   Tue Feb 17 07:48:24 2026 MJ, KD,VM,IC, RC, DNUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 17 fevrier 2026 

7h50 : mise en chauffe en remote (frigo/chillers, modulateur, laser, cyclage)

Le cyclage de RI-C1/QP.08, RI-C1/QP.11 et RI-C2/QP.03 ne démarre pas tout seul (action nécessaire sur le boutton cyclage de l'élément).

Programme - Etude "IP dromadaire" ==> Scan pos horizontale FPC + phase 

Positions FENTES2/HEXA des 2 derniers shifts :
    Pos FENTE2 :    [H , V]  = [-3 , -10.20]
    Pos HEXA ech : [Tx , Ty] = [+79 , +31]

10h00 Beam is in the ring W/O RF, -120 pC, receipt saved: recipe_recipe_LI_TL_RI_all_20260217_09_44_16.txt on the base of reference for 50 MeV

recipe_recipe_LI_TL_straight_all_20260217_10_08_07.txt for the linac and the TL stright part

RF 100 kV phase -48.5 dg.

10h35 Standby, Changing the FPC controller

11h23 HV is on

11h40 RCDSon injection

11h59 RF gun phase 23 dg., Sect. Att. 2.39 dB, Phase 230 dg., Charges: (ICT) from -120 to 140 pc, (BPMs) -137, -137, 137, 137 pC

tunes: H 0.166, V 0.71

12h26 tunes: H 0.167, V 0.72. MRSV size is very sensetive to injection settings

At around 2:45 p.m., the power to the ring dipole went out.

16h42 RF 280 kV, phase -50 dg. Streak camera measurements for 100 kV and 280 kV

Orbit bump to change orbit tilt around IP

18h59 Stop ThomX

 

 

 

Attachment 1: Screenshot_from_2026-02-17_13-06-31.png
Screenshot_from_2026-02-17_13-06-31.png
Attachment 2: Screenshot_from_2026-02-17_13-06-18.png
Screenshot_from_2026-02-17_13-06-18.png
Attachment 3: Screenshot_from_2026-02-17_12-48-03.png
Screenshot_from_2026-02-17_12-48-03.png
Attachment 4: Screenshot_from_2026-02-17_12-47-33.png
Screenshot_from_2026-02-17_12-47-33.png
Attachment 5: Screenshot_from_2026-02-17_12-47-04.png
Screenshot_from_2026-02-17_12-47-04.png
Attachment 6: Screenshot_from_2026-02-17_12-37-42.png
Screenshot_from_2026-02-17_12-37-42.png
Attachment 7: Screenshot_from_2026-02-17_18-30-41.png
Screenshot_from_2026-02-17_18-30-41.png
Attachment 8: Screenshot_from_2026-02-17_18-29-37.png
Screenshot_from_2026-02-17_18-29-37.png
Attachment 9: Screenshot_from_2026-02-17_18-03-02.png
Screenshot_from_2026-02-17_18-03-02.png
Attachment 10: Screenshot_from_2026-02-17_18-02-44.png
Screenshot_from_2026-02-17_18-02-44.png
  981   Tue Dec 17 08:09:41 2024 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 17 décembre 2024 

8h10 : mise en chauffe de la machine (modulateur, laser, frigo et chiller)

9h30: faisceau dans anneau avec 100pC injecté

Problème modulateur (interlock tension) ==> attendre que la perverance déscende en trig à faible tension pendant 1h (Maher a augmenté la valeur du threshold, le problème ne devrait pas revenir)

9h35 HV is 1214 V, RF Gun phase is 176 dg. Sect. Att. 2.578 dB, Phase is 216 dg. Charges -84 pC, -72 pC, -76 pC

10h40 HV 1215 V

13h24 Linc steerers H [2.65 -4.29], V [-1.8  2.07] RF Gun Phase 175 dg. Sect. Att. 2.564, Phase 217 dg. Charges: -117 pC, -117 pC, -127 pC

Several vertical scans were performed for different initial beam charge with X ray flux in async mode

Decay time data taken.

 

End of shift 18h.

 

  Draft   Wed Dec 17 07:17:06 2025 KD, IC, MV, DN,Under ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 17 décembre 2025 

7h15: mise en chauffe en remote (chiller/frigo, laser, modulateur, cyclage)

8h33 HV ON

09h30 Beam is in the ring 40 MeV, RF 100 kV ==> 150 kV I3+I4 up to 14000 pA. Vertical step at IP from -2 mm to +2 mm. MRSW 24.5 pix. Receipt  recipe_recipe_LI_TL_RI_all_20251217_09_17_49.txt

10h19 Hor. tune 0.177, sum of TbTsum 2e11. TL/BPM02 X=+3 mm, RF cavity phase 5 dg. Sect Att. 3.967 dB, Sect. phase 197 dg. RF gun phase 222 dg. Charges: -165, -157, -159, -161, -158 pA Laser Att. 300, Sol. 223 A

 

 

*** Programme ***

* faire 1 à 2 tomographie à 40 Mev avant de passer aux manips à 70MeV (besoin de flux pour la rapidité d'acquisition)

* passage à 70MeV, mesure de dosimétrie et spectre angulaire

  1121   Tue Sep 16 12:11:42 2025 KDUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 16 septembre 2025 

12h: mise en chauffe (modulateur, frigo/chiller, laser, cyclage)

==> plantage IHM cyclage (2fois)

12h15: Stop machine ==> pas besoin pour la CFP 

*** Programme CFP ***

  Draft   Thu Oct 16 07:37:52 2025 KD, IC, VMUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 16 octobre 2025 

7h30: mise en chauffe en remote (chillers/frigo, laser, cyclage)

==> impossible de passer en Standby sur le modulateur ==> mail envoyé à Maher.

8h30 We inspected the modulator, made the rondes. The error (status 8 bit) remains. Need for help from Maher. problem: Modumator PSS.

09h12 Maher started the modulator (there was problem with cooling)

10h30 HV is ON

10h44 RF Gun phase is 228 dg Laser Att. 280, Charge device does not work properly

11h18 RCDS on injection, Beam is in the ring

11h20 Modulator went to OFF then start to warm-up

The RF cavity DS  can not read ring RF frequency

12h28 HV ON

Restarting the beam

Working on the WP 50 MeV, orbit correction after dipole rotation. Recette:

TL and EL tuning and measurement of the energy spread.

Beam cut issue in EL investigations.

Optics studies. LOCO.

19h50 STOp THOMX

Attachment 1: Screenshot_from_2025-10-16_19-07-23.png
Screenshot_from_2025-10-16_19-07-23.png
Attachment 2: Screenshot_from_2025-10-16_18-49-04.png
Screenshot_from_2025-10-16_18-49-04.png
Attachment 3: EL_EnergySpread.png
EL_EnergySpread.png
Attachment 4: Screenshot_from_2025-10-16_19-11-13.png
Screenshot_from_2025-10-16_19-11-13.png
Attachment 5: Screenshot_from_2025-10-16_19-20-55.png
Screenshot_from_2025-10-16_19-20-55.png
Attachment 6: TL_EnergySpread.png
TL_EnergySpread.png
  1102   Wed Jul 16 09:09:13 2025 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 16 juillet 2025 

9h07 : Mise en chauffe (frigo/chiller, modulateur, laser, cyclage)

FPC laser stability and lock observation.

Change the RF frequency to work at 50 MeV. Tuning of the FPC.

The recette "Flat orbit"

During the day we observe the very big variation of the synchrotron oscillation amplitude (very difficult to find the ring working conditions) in the ring, sudden charge variation.

14h40 measurement of the synch osillations for 200 injections

Amplitude deviation = 33.3028%
Frequency deviation = 0.91508% (267.9607 kHz)
Phase deviation = 46.4524 degrees orbit
Average position deviation = 1.4408%

Vertical orbit correction studies


 

 

Attachment 1: Sautes_de_Charge_2025-07-16_14-13-34.png
Sautes_de_Charge_2025-07-16_14-13-34.png
  1170   Tue Dec 16 07:18:46 2025 KD, IC, RC,VM Under ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 16 décembre 2025 

7h10: mise en chauffe en remote (chiller/frigo, laser, cyclage, modulateur).

à cause du faible flux d'hier et de la non répétabilité des recettes de la semaine précédente :

* essaie avec la section à 28.4°C (seule condition différente de mardi dernier)

8h10: démarrage. 

chargement de la recette du "recipe_recipe_LI_TL_RI_all_20251209_17_54_51.txt", rien sur la caméra sst, on retrouve les paramètres de mardi (3.74dB, 210°C phase section)

image SST vraiment décalé ==> quelques chose à bougé sur la machine ? ==> réalignement quads

** après réalignement et ajustement (phase + atténuateur) 

 

e-:

attenuateur section : 3.77dB

phase section : 214°

chiller: 28.4°C

Freq: 500.11851 MHz

phase shifter manuel : 8600

longueur paquet pas assez de MRSV pour la mesure

10h43 Results: T_sect. 30dg.C (consigne 29.2), laser spot position: 4.714 H, 3.524 V; starting from the receipt recipe_recipe_LI_TL_RI_all_20251211_14_07_28.txt

RF gun phase 222 dg., Sect. Att. 3.987, phase 197 dg. TL/BPM02 X= +2 mm, Linac steerers: H [0.97 -3.6], V [-3.0 3.9], Charges (BPMs): -115, -109, -112, -112, -112 pC, 

Beam in the ring after RCDS on TL RF 100 kV, phase 9.0 dg. MRSV 27 pix, (sometime 22 pix). RCDS on ring V cor. X I3+I4 up to 12000 pA but with vertical step at IP ( recipe_recipe_LI_TL_RI_all_20251216_10_41_50.txt)

10h58 Went to the receipt recipe_recipe_LI_TL_RI_all_20251216_10_09_21.txt to have more flat vertical orbit (4000 pA after FPC table scan)

QUAD cycling

11h30 We reoptimized the vertical orbit to have smaller angle. I3+I4 ~7-8 kpA Receipt: recipe_recipe_LI_TL_RI_all_20251216_11_29_31.txt (MRSV 24 - 26 pix, Hor. tune 0.2 at maximum flux)

18h20 Laser Att ==>297 ,charges:-159,-152,-157,-156,-155 pC, Solenoid 225 A, Sum of TbTsum 2e11, from 15e11, MRSV 35.8 pix, I3+I4 about 8000, then FPC desynchronized.

18h43 Stop ThomX

Attachment 1: 2025-12-16_08_30_21_tl_dg_sst_02-ccd_01_RAW.png
2025-12-16_08_30_21_tl_dg_sst_02-ccd_01_RAW.png
Attachment 2: 2025-12-16_08_35_25_tl_dg_sst_02-ccd_01_RAW.png
2025-12-16_08_35_25_tl_dg_sst_02-ccd_01_RAW.png
  817   Wed Nov 15 09:13:06 2023 KD, MJ, RCUnder ProcessShift summaryLI | TL | LE | Ring | Laser | Opt | SY shift du 15 novembre 2023 

9h : mise en chauffe de la machine

12h: intervention Iryna et Slava pour un meilleur stockage dans l'anneau (recette semaine passé)

Recherche de la phase et du bucket Laser/e-

- X trouvé (cf. screen shots et datas) :

* bucket Laser/trigger = 21.5ns (visu au scope)

* Dephaseur 500MHz (ER/CA/RAC.05-API.AO1) : 5.3 V (à affiner)

* Cavité trop instable avec le lock sur la fréquence RF (délock en moins de qq minutes)

 

*** Passage dans la EL (uniquement jusqu'au BPM) avec :

qp1 qp2 qp3 = 1.5   -2.6   0.7

kicker 5840 V retard -7.96

dpi 0.8 A

dp 160.1 A

--> TBTSUM ne peut pas etre utilise pour estimer la charge entrante anneau / sortante anneau car : TBTSUM sortant > TBTSUM entrant (cf screenshot de 15h44)

 

*** Mesure de la taille e- a l'IP avec table FPC - Fin de journee, a voir si ces mesures permettent d'extraire taille e-

 

*** Remarques ***

- Beaucoup de claquage au niveau du modulateur/Klystron (cf. TL/BPM.02 trend)

*** Programme ***

- Optimization du flux de rayons X (ajustement phase/synchro, ajustement position laser)

- passage dans la Ligne d'Extraction

Attachment 1: Screenshot_2023-11-15_16-40-54.png
Screenshot_2023-11-15_16-40-54.png
Attachment 2: Screenshot_2023-11-15_17-38-44.png
Screenshot_2023-11-15_17-38-44.png
Attachment 3: pico_I1_Xsearch.dat
# DATASET= "xli/op/tmd.01/i1[0]"
# SNAPSHOT_TIME= 2023-11-15_17:17:07.459186
2023-11-15_15:27:53.556484	274.074815821472
2023-11-15_15:27:53.656761	274.074815821472
2023-11-15_15:27:53.757046	272.7549293088239
2023-11-15_15:27:53.857399	272.7549293088239
2023-11-15_15:27:53.956674	272.7549293088239
2023-11-15_15:27:54.056986	272.7549293088239
2023-11-15_15:27:54.157231	272.7549293088239
2023-11-15_15:27:54.256462	274.25029206303793
2023-11-15_15:27:54.356794	274.25029206303793
2023-11-15_15:27:54.457050	274.25029206303793
2023-11-15_15:27:54.557337	274.25029206303793
2023-11-15_15:27:54.656632	274.25029206303793
2023-11-15_15:27:54.756926	273.1249552964738
2023-11-15_15:27:54.857279	273.1249552964738
2023-11-15_15:27:54.956542	273.1249552964738
2023-11-15_15:27:55.056818	273.1249552964738
2023-11-15_15:27:55.157091	273.1249552964738
2023-11-15_15:27:55.257369	274.2846243711704
2023-11-15_15:27:55.356737	274.2846243711704
2023-11-15_15:27:55.457037	274.2846243711704
2023-11-15_15:27:55.557300	274.2846243711704
2023-11-15_15:27:55.656560	274.2846243711704
2023-11-15_15:27:55.756824	272.4688267410533
2023-11-15_15:27:55.857143	272.4688267410533
2023-11-15_15:27:55.956415	272.4688267410533
2023-11-15_15:27:56.056710	272.4688267410533
2023-11-15_15:27:56.157014	272.4688267410533
2023-11-15_15:27:56.257297	274.99034403833775
2023-11-15_15:27:56.356630	274.99034403833775
2023-11-15_15:27:56.456904	274.99034403833775
2023-11-15_15:27:56.557192	274.99034403833775
2023-11-15_15:27:56.656496	274.99034403833775
2023-11-15_15:27:56.756779	274.97127053381973
2023-11-15_15:27:56.857143	274.97127053381973
2023-11-15_15:27:56.956413	274.97127053381973
2023-11-15_15:27:57.056666	274.97127053381973
2023-11-15_15:27:57.156974	274.97127053381973
2023-11-15_15:27:57.257252	275.60832558472214
2023-11-15_15:27:57.356554	275.60832558472214
2023-11-15_15:27:57.456793	275.60832558472214
2023-11-15_15:27:57.557075	275.60832558472214
2023-11-15_15:27:57.657292	275.60832558472214
2023-11-15_15:27:57.756568	271.6105190377417
2023-11-15_15:27:57.856877	271.6105190377417
2023-11-15_15:27:57.957194	271.6105190377417
2023-11-15_15:27:58.056485	271.6105190377417
2023-11-15_15:27:58.156783	271.6105190377417
2023-11-15_15:27:58.257064	273.5216841904489
2023-11-15_15:27:58.356455	273.5216841904489
2023-11-15_15:27:58.456722	273.5216841904489
2023-11-15_15:27:58.556999	273.5216841904489
2023-11-15_15:27:58.657293	273.5216841904489
2023-11-15_15:27:58.756589	273.9260424862313
2023-11-15_15:27:58.856962	273.9260424862313
2023-11-15_15:27:58.957273	273.9260424862313
2023-11-15_15:27:59.056547	273.9260424862313
2023-11-15_15:27:59.156821	273.9260424862313
2023-11-15_15:27:59.257126	273.453019574184
2023-11-15_15:27:59.356492	273.453019574184
2023-11-15_15:27:59.456765	273.453019574184
2023-11-15_15:27:59.556997	273.453019574184
2023-11-15_15:27:59.657327	273.453019574184
2023-11-15_15:27:59.756634	273.73912214195457
2023-11-15_15:27:59.856973	273.73912214195457
2023-11-15_15:27:59.957236	273.73912214195457
2023-11-15_15:28:00.056530	273.73912214195457
2023-11-15_15:28:00.156833	273.73912214195457
2023-11-15_15:28:00.257151	271.69444245762105
2023-11-15_15:28:00.356484	271.69444245762105
2023-11-15_15:28:00.456794	271.69444245762105
2023-11-15_15:28:00.557097	271.69444245762105
2023-11-15_15:28:00.656394	271.69444245762105
2023-11-15_15:28:00.756703	275.0551939536991
2023-11-15_15:28:00.857053	275.0551939536991
2023-11-15_15:28:00.956395	275.0551939536991
2023-11-15_15:28:01.056712	275.0551939536991
2023-11-15_15:28:01.156934	275.0551939536991
2023-11-15_15:28:01.257069	272.4688267410533
2023-11-15_15:28:01.356502	272.4688267410533
2023-11-15_15:28:01.456776	272.4688267410533
2023-11-15_15:28:01.557045	272.4688267410533
2023-11-15_15:28:01.657289	272.4688267410533
2023-11-15_15:28:01.756550	273.93748658894214
2023-11-15_15:28:01.856900	273.93748658894214
2023-11-15_15:28:01.957192	273.93748658894214
2023-11-15_15:28:02.056486	273.93748658894214
2023-11-15_15:28:02.156776	273.93748658894214
2023-11-15_15:28:02.257103	273.2889874353289
2023-11-15_15:28:02.356430	273.2889874353289
2023-11-15_15:28:02.456709	273.2889874353289
2023-11-15_15:28:02.556985	273.2889874353289
2023-11-15_15:28:02.657284	273.2889874353289
2023-11-15_15:28:02.756588	274.3914359964714
2023-11-15_15:28:02.856975	274.3914359964714
2023-11-15_15:28:02.957231	274.3914359964714
2023-11-15_15:28:03.056504	274.3914359964714
2023-11-15_15:28:03.156781	274.3914359964714
2023-11-15_15:28:03.257056	273.06392008201607
2023-11-15_15:28:03.356420	273.06392008201607
2023-11-15_15:28:03.456715	273.06392008201607
2023-11-15_15:28:03.556948	273.06392008201607
2023-11-15_15:28:03.657262	273.06392008201607
2023-11-15_15:28:03.756564	274.57454163984454
2023-11-15_15:28:03.856875	274.57454163984454
2023-11-15_15:28:03.957186	274.57454163984454
2023-11-15_15:28:04.056440	274.57454163984454
2023-11-15_15:28:04.156731	274.57454163984454
2023-11-15_15:28:04.257000	273.27372863171445
2023-11-15_15:28:04.357359	273.27372863171445
2023-11-15_15:28:04.456683	273.27372863171445
2023-11-15_15:28:04.557010	273.27372863171445
2023-11-15_15:28:04.657277	273.27372863171445
2023-11-15_15:28:04.756596	273.540757694967
2023-11-15_15:28:04.856966	273.540757694967
2023-11-15_15:28:04.957278	273.540757694967
2023-11-15_15:28:05.056545	273.540757694967
2023-11-15_15:28:05.156830	273.540757694967
2023-11-15_15:28:05.257089	272.95710845671505
2023-11-15_15:28:05.356422	272.95710845671505
2023-11-15_15:28:05.456685	272.95710845671505
2023-11-15_15:28:05.556961	272.95710845671505
2023-11-15_15:28:05.657245	272.95710845671505
2023-11-15_15:28:05.756560	274.61650334978424
2023-11-15_15:28:05.856881	274.61650334978424
2023-11-15_15:28:05.957156	274.61650334978424
2023-11-15_15:28:06.056386	274.61650334978424
2023-11-15_15:28:06.156623	274.61650334978424
2023-11-15_15:28:06.256947	272.8007057196672
2023-11-15_15:28:06.357299	272.8007057196672
2023-11-15_15:28:06.456594	272.8007057196672
2023-11-15_15:28:06.556863	272.8007057196672
2023-11-15_15:28:06.657187	272.8007057196672
2023-11-15_15:28:06.756458	273.9222277853277
2023-11-15_15:28:06.856782	273.9222277853277
2023-11-15_15:28:06.957054	273.9222277853277
2023-11-15_15:28:07.057329	273.9222277853277
2023-11-15_15:28:07.156607	273.9222277853277
2023-11-15_15:28:07.256845	272.4611973392461
2023-11-15_15:28:07.357117	272.4611973392461
2023-11-15_15:28:07.456296	272.4611973392461
2023-11-15_15:28:07.556587	272.4611973392461
2023-11-15_15:28:07.656908	272.4611973392461
2023-11-15_15:28:07.757228	275.4404787449634
2023-11-15_15:28:07.856582	275.4404787449634
2023-11-15_15:28:07.956845	275.4404787449634
2023-11-15_15:28:08.057174	275.4404787449634
2023-11-15_15:28:08.156451	275.4404787449634
2023-11-15_15:28:08.256701	272.1560212669575
2023-11-15_15:28:08.357026	272.1560212669575
2023-11-15_15:28:08.457334	272.1560212669575
2023-11-15_15:28:08.556586	272.1560212669575
2023-11-15_15:28:08.656892	272.1560212669575
2023-11-15_15:28:08.757187	272.7625587106311
2023-11-15_15:28:08.856513	272.7625587106311
2023-11-15_15:28:08.956786	272.7625587106311
2023-11-15_15:28:09.057058	272.7625587106311
2023-11-15_15:28:09.156342	272.7625587106311
2023-11-15_15:28:09.256649	274.5974298452662
2023-11-15_15:28:09.356969	274.5974298452662
2023-11-15_15:28:09.457298	274.5974298452662
2023-11-15_15:28:09.556546	274.5974298452662
2023-11-15_15:28:09.656840	274.5974298452662
2023-11-15_15:28:09.757152	272.6061559735832
2023-11-15_15:28:09.856476	272.6061559735832
2023-11-15_15:28:09.956750	272.6061559735832
2023-11-15_15:28:10.057042	272.6061559735832
2023-11-15_15:28:10.156362	272.6061559735832
2023-11-15_15:28:10.256641	274.1511098395441
2023-11-15_15:28:10.356972	274.1511098395441
2023-11-15_15:28:10.457241	274.1511098395441
2023-11-15_15:28:10.556516	274.1511098395441
2023-11-15_15:28:10.656851	274.1511098395441
2023-11-15_15:28:10.757126	272.5527501609327
2023-11-15_15:28:10.856462	272.5527501609327
2023-11-15_15:28:10.956706	272.5527501609327
2023-11-15_15:28:11.056958	272.5527501609327
2023-11-15_15:28:11.157209	272.5527501609327
2023-11-15_15:28:11.256953	274.03666881243595
2023-11-15_15:28:11.356331	274.03666881243595
2023-11-15_15:28:11.456604	274.03666881243595
2023-11-15_15:28:11.556843	274.03666881243595
2023-11-15_15:28:11.657077	274.03666881243595
2023-11-15_15:28:11.756319	273.5483870967742
2023-11-15_15:28:11.856646	273.5483870967742
2023-11-15_15:28:11.956916	273.5483870967742
2023-11-15_15:28:12.057205	273.5483870967742
2023-11-15_15:28:12.156500	273.5483870967742
2023-11-15_15:28:12.256789	273.00669956846195
2023-11-15_15:28:12.357160	273.00669956846195
2023-11-15_15:28:12.456432	273.00669956846195
2023-11-15_15:28:12.556709	273.00669956846195
2023-11-15_15:28:12.656980	273.00669956846195
2023-11-15_15:28:12.757219	273.9222277853277
2023-11-15_15:28:12.856549	273.9222277853277
2023-11-15_15:28:12.956831	273.9222277853277
2023-11-15_15:28:13.057113	273.9222277853277
2023-11-15_15:28:13.156404	273.9222277853277
2023-11-15_15:28:13.256705	272.6023412726796
2023-11-15_15:28:13.357024	272.6023412726796
2023-11-15_15:28:13.457295	272.6023412726796
2023-11-15_15:28:13.556566	272.6023412726796
2023-11-15_15:28:13.656872	272.6023412726796
2023-11-15_15:28:13.757176	274.03285411153234
2023-11-15_15:28:13.856468	274.03285411153234
2023-11-15_15:28:13.956700	274.03285411153234
2023-11-15_15:28:14.056968	274.03285411153234
2023-11-15_15:28:14.157274	274.03285411153234
2023-11-15_15:28:14.256556	273.5140547886417
2023-11-15_15:28:14.356884	273.5140547886417
2023-11-15_15:28:14.457136	273.5140547886417
2023-11-15_15:28:14.556474	273.5140547886417
2023-11-15_15:28:14.656814	273.5140547886417
2023-11-15_15:28:14.757052	273.96037479436376
2023-11-15_15:28:14.856345	273.96037479436376
2023-11-15_15:28:14.956621	273.96037479436376
2023-11-15_15:28:15.056892	273.96037479436376
2023-11-15_15:28:15.157172	273.96037479436376
2023-11-15_15:28:15.256447	273.1554729037026
2023-11-15_15:28:15.356761	273.1554729037026
2023-11-15_15:28:15.457020	273.1554729037026
2023-11-15_15:28:15.557292	273.1554729037026
2023-11-15_15:28:15.656563	273.1554729037026
2023-11-15_15:28:15.756837	272.9799966621367
2023-11-15_15:28:15.857124	272.9799966621367
2023-11-15_15:28:15.956413	272.9799966621367
2023-11-15_15:28:16.056658	272.9799966621367
2023-11-15_15:28:16.156989	272.9799966621367
2023-11-15_15:28:16.257303	274.1663686431586
2023-11-15_15:28:16.356626	274.1663686431586
2023-11-15_15:28:16.456897	274.1663686431586
2023-11-15_15:28:16.557173	274.1663686431586
2023-11-15_15:28:16.656434	274.1663686431586
2023-11-15_15:28:16.756709	272.7511146079203
2023-11-15_15:28:16.857076	272.7511146079203
2023-11-15_15:28:16.956315	272.7511146079203
2023-11-15_15:28:17.056597	272.7511146079203
2023-11-15_15:28:17.156911	272.7511146079203
2023-11-15_15:28:17.257179	272.9304055503898
2023-11-15_15:28:17.356528	272.9304055503898
2023-11-15_15:28:17.456795	272.9304055503898
2023-11-15_15:28:17.557060	272.9304055503898
2023-11-15_15:28:17.656350	272.9304055503898
2023-11-15_15:28:17.756624	274.5478387335193
2023-11-15_15:28:17.856982	274.5478387335193
2023-11-15_15:28:17.957215	274.5478387335193
2023-11-15_15:28:18.056504	274.5478387335193
2023-11-15_15:28:18.156827	274.5478387335193
2023-11-15_15:28:18.257092	273.10206709105216
2023-11-15_15:28:18.356413	273.10206709105216
2023-11-15_15:28:18.456714	273.10206709105216
2023-11-15_15:28:18.556953	273.10206709105216
2023-11-15_15:28:18.657263	273.10206709105216
2023-11-15_15:28:18.756526	464.82130510454664
2023-11-15_15:28:18.856886	464.82130510454664
2023-11-15_15:28:18.957154	464.82130510454664
2023-11-15_15:28:19.056472	464.82130510454664
2023-11-15_15:28:19.156775	464.82130510454664
2023-11-15_15:28:19.257030	273.62849581574994
2023-11-15_15:28:19.356374	273.62849581574994
2023-11-15_15:28:19.456637	273.62849581574994
2023-11-15_15:28:19.556903	273.62849581574994
2023-11-15_15:28:19.657163	273.62849581574994
2023-11-15_15:28:19.756470	274.1511098395441
2023-11-15_15:28:19.856829	274.1511098395441
2023-11-15_15:28:19.957122	274.1511098395441
2023-11-15_15:28:20.056368	274.1511098395441
2023-11-15_15:28:20.156670	274.1511098395441
2023-11-15_15:28:20.256956	272.68626469255895
2023-11-15_15:28:20.357256	272.68626469255895
2023-11-15_15:28:20.456525	272.68626469255895
2023-11-15_15:28:20.556824	272.68626469255895
2023-11-15_15:28:20.657147	272.68626469255895
2023-11-15_15:28:20.756474	420.05579000071526
2023-11-15_15:28:20.856844	420.05579000071526
2023-11-15_15:28:20.957108	420.05579000071526
2023-11-15_15:28:21.056423	420.05579000071526
2023-11-15_15:28:21.156743	420.05579000071526
2023-11-15_15:28:21.256676	273.1669170064135
2023-11-15_15:28:21.356444	273.1669170064135
2023-11-15_15:28:21.456701	273.1669170064135
2023-11-15_15:28:21.556979	273.1669170064135
2023-11-15_15:28:21.657293	273.1669170064135
2023-11-15_15:28:21.756553	275.1925231862289
2023-11-15_15:28:21.856882	275.1925231862289
2023-11-15_15:28:21.957143	275.1925231862289
2023-11-15_15:28:22.056415	275.1925231862289
2023-11-15_15:28:22.156804	275.1925231862289
2023-11-15_15:28:22.257086	272.04539494075294
2023-11-15_15:28:22.356384	272.04539494075294
2023-11-15_15:28:22.456612	272.04539494075294
2023-11-15_15:28:22.556884	272.04539494075294
2023-11-15_15:28:22.657134	272.04539494075294
2023-11-15_15:28:22.756438	297.5581145840784
2023-11-15_15:28:22.856764	297.5581145840784
2023-11-15_15:28:22.957035	297.5581145840784
2023-11-15_15:28:23.056308	297.5581145840784
2023-11-15_15:28:23.156590	297.5581145840784
2023-11-15_15:28:23.256867	273.2279522208712
... 65240 more lines ...
Attachment 4: ri-c1_dg_bpm.02-lib.03_tbtsum.dat
# DATASET= "ri-c1/dg/bpm.02-lib.03/tbtsum"
# SNAPSHOT_TIME= 2023-11-15_17:40:01.349767
0.0	12980969.0
1.0	13050255.0
2.0	13276450.0
3.0	13509630.0
4.0	13192362.0
5.0	13498144.0
6.0	13544940.0
7.0	12514236.0
8.0	6030154.0
9.0	770772.0
10.0	701051.0
11.0	486523.0
12.0	600571.0
13.0	1351314.0
14.0	25099982.0
15.0	58769910.0
16.0	48190087.0
17.0	43998639.0
18.0	42506852.0
19.0	43542601.0
20.0	41854215.0
21.0	42810233.0
22.0	42939644.0
23.0	42069186.0
24.0	43076036.0
25.0	42712638.0
26.0	42003672.0
27.0	42851171.0
28.0	41635893.0
29.0	41395522.0
30.0	42293262.0
31.0	40463059.0
32.0	40190395.0
33.0	40949816.0
34.0	39360445.0
35.0	38895533.0
36.0	39686256.0
37.0	38645595.0
38.0	38373030.0
39.0	38860599.0
40.0	38236507.0
41.0	37760424.0
42.0	38346007.0
43.0	37916580.0
44.0	37631087.0
45.0	38432025.0
46.0	37957915.0
47.0	37974655.0
48.0	38775405.0
49.0	37739676.0
50.0	37927450.0
51.0	38386792.0
52.0	37728169.0
53.0	38233098.0
54.0	38531120.0
55.0	37833220.0
56.0	38420138.0
57.0	38320865.0
58.0	37689086.0
59.0	38268760.0
60.0	38014930.0
61.0	37234821.0
62.0	37643457.0
63.0	37476014.0
64.0	36953064.0
65.0	37519703.0
66.0	37200292.0
67.0	36495418.0
68.0	36950350.0
69.0	36983397.0
70.0	36404578.0
71.0	36859125.0
72.0	36500158.0
73.0	36384885.0
74.0	36624883.0
75.0	36524163.0
76.0	36322177.0
77.0	36578173.0
78.0	36462210.0
79.0	36372893.0
80.0	36704742.0
81.0	36413790.0
82.0	36626405.0
83.0	36955715.0
84.0	36454834.0
85.0	36723062.0
86.0	36735990.0
87.0	36365391.0
88.0	36421496.0
89.0	36533559.0
90.0	35997672.0
91.0	35951681.0
92.0	36064532.0
93.0	35725449.0
94.0	35744106.0
95.0	35776617.0
96.0	35620206.0
97.0	35824092.0
98.0	35463120.0
99.0	35343605.0
100.0	35416628.0
101.0	35490704.0
102.0	35361629.0
103.0	35531865.0
104.0	35282894.0
105.0	35093648.0
106.0	35168387.0
107.0	35160271.0
108.0	35224284.0
109.0	35605176.0
110.0	35430188.0
111.0	35379950.0
112.0	35600154.0
113.0	35449167.0
114.0	35299246.0
115.0	35477320.0
116.0	35288905.0
117.0	35170008.0
118.0	35343215.0
119.0	35012704.0
120.0	34832168.0
121.0	35079087.0
122.0	35017391.0
123.0	34764448.0
124.0	34707064.0
125.0	35005822.0
126.0	34687273.0
127.0	34716465.0
128.0	34779597.0
129.0	34594991.0
130.0	34618538.0
131.0	34671310.0
132.0	34414319.0
133.0	34417561.0
134.0	34496599.0
135.0	34522816.0
136.0	34559233.0
137.0	34741591.0
138.0	34832870.0
139.0	34800065.0
140.0	34571370.0
141.0	34703575.0
142.0	34752268.0
143.0	34421832.0
144.0	34447848.0
145.0	34499500.0
146.0	34491256.0
147.0	34531905.0
148.0	34369492.0
149.0	34118954.0
150.0	34348901.0
151.0	34307235.0
152.0	34164129.0
153.0	34131080.0
154.0	33970856.0
155.0	33983255.0
156.0	34089870.0
157.0	34087341.0
158.0	33944585.0
159.0	34096869.0
160.0	34035872.0
161.0	33933222.0
162.0	33947426.0
163.0	34197035.0
164.0	34108859.0
165.0	34128576.0
166.0	34203379.0
167.0	34236245.0
168.0	34275575.0
169.0	34081569.0
170.0	34102262.0
171.0	34060632.0
172.0	34132823.0
173.0	33920245.0
174.0	33773616.0
175.0	33646824.0
176.0	33474619.0
177.0	33756785.0
178.0	33670418.0
179.0	33656943.0
180.0	33626831.0
181.0	33597245.0
182.0	33614802.0
183.0	33655652.0
184.0	33598513.0
185.0	33555010.0
186.0	33651876.0
187.0	33637122.0
188.0	33430173.0
189.0	33506965.0
190.0	33744388.0
191.0	33631441.0
192.0	33759066.0
193.0	33741106.0
194.0	33490636.0
195.0	33673888.0
196.0	33540546.0
197.0	33909490.0
198.0	33821622.0
199.0	33639467.0
200.0	33577981.0
201.0	33748006.0
202.0	33834911.0
203.0	33550190.0
204.0	33488611.0
205.0	33490447.0
206.0	33510405.0
207.0	33427598.0
208.0	33432487.0
209.0	33344124.0
210.0	33115879.0
211.0	33131276.0
212.0	33184865.0
213.0	33224565.0
214.0	33311949.0
215.0	33112693.0
216.0	33083067.0
217.0	33106195.0
218.0	33274861.0
219.0	33370761.0
220.0	33435270.0
221.0	33344442.0
222.0	33355760.0
223.0	33440969.0
224.0	33394076.0
225.0	33437929.0
226.0	33458737.0
227.0	33172329.0
228.0	33229852.0
229.0	33311333.0
230.0	33436661.0
231.0	33278200.0
232.0	33351802.0
233.0	32996600.0
234.0	33081654.0
235.0	33096349.0
236.0	33129460.0
237.0	33070956.0
238.0	32822604.0
239.0	32757318.0
240.0	32820772.0
241.0	32872282.0
242.0	32953407.0
243.0	33035721.0
244.0	33051772.0
245.0	32928770.0
246.0	32995623.0
247.0	33054625.0
248.0	33200880.0
249.0	33304632.0
250.0	33255412.0
251.0	33206693.0
252.0	33109150.0
253.0	33135041.0
254.0	33259510.0
255.0	33399785.0
256.0	33226872.0
257.0	33170283.0
258.0	33073336.0
259.0	33119453.0
260.0	33049758.0
261.0	32946916.0
262.0	32851445.0
263.0	32914560.0
264.0	32724975.0
265.0	32876842.0
266.0	32842023.0
267.0	32793655.0
268.0	32562408.0
269.0	32751076.0
270.0	32880111.0
271.0	32605949.0
272.0	32663662.0
273.0	32818193.0
274.0	32750576.0
275.0	32798306.0
276.0	32850462.0
277.0	32955060.0
278.0	33039462.0
279.0	32994296.0
280.0	33108217.0
281.0	33003870.0
282.0	32791885.0
283.0	32847882.0
284.0	33013968.0
285.0	32801961.0
286.0	32700561.0
287.0	32785009.0
288.0	32786504.0
289.0	32652862.0
290.0	32728946.0
291.0	32723497.0
292.0	32831532.0
293.0	32585955.0
294.0	32708750.0
295.0	32811399.0
296.0	32658550.0
297.0	32665180.0
... 704 more lines ...
Attachment 5: oscilloscope_RI.png
oscilloscope_RI.png
Attachment 6: Screenshot_from_2023-11-15_15-44-28.png
Screenshot_from_2023-11-15_15-44-28.png
  1070   Thu May 15 07:54:16 2025 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 15 mai 2025 

7h50: mise en chauffe à distance (Modulateur, chiller/frigo, laser)

cyclage aimant bug ==> impossible de cycler les aimants, trop de plantage

Soleno scan : Iris 0.5 mm --> on retrouve la symétrie : le laser donne cette dissymétrie ...

100pC et 150 pC

 

*** Programme ***

- refaire du faisceau de rayons X.

- Optimisation de l'injection (haute charge et/ou nouvelle lattice, cf. Viktor)

Attachment 1: Size_vs_SolenoScan_18-03-13.png
Size_vs_SolenoScan_18-03-13.png
Attachment 2: Size_vs_SolenoScan_18-12-12.png
Size_vs_SolenoScan_18-12-12.png
  996   Wed Jan 15 08:16:32 2025 MJ KD VC HGUnder ProcessShift summaryAimants | Linac Commissionning | Ring Commissioning shift du 15 janvier 2025 

8h15 : mise en chauffe de la machine à distance (modulateur, laser, frigo, chiller)

faisceau Linac et TL non déviée  => manip pour la comphéension des sauts.
Pos laser H4.374 V3.36
Phase canon Emax 162
best foc sut Li YAG1   250A
QEmax  130pC
LI Str 1 H 2.38  V -1.9
LI Str 2 H -4.16  V 2.05
phase section (non optimisée) 213
Dipole off

Avec ou sans Q1 à Q3 les saut sont visibles sur TL/BPM1 et TL/SST1

relation courant steerer/pos faisceau TL\BPM1


LI str2  +-0.1A => +-500µm position
LI str1  +-0.1A => +-300µm position

V
LI str2  +-0.1A => +-500µm position
LI str1  +-0.1A => +-500µm position

test nB step versus frequence canon

Q beam 25pC

11h27  => freq gun 25Hz   11h37
11h37  => freq gun 1Hz     

(Njumps / delta_t) decreased with beam repetition rate --> most likely a charge effect  

15h30 Alex fait 3/4 de tour de cle Q1-Q3 (q3 vers le mur, ~0.5-0.7 mrad)
Ca ne semble pas changer grand chose sur alignement q5_q7 ... a verifier + axe q1_q3 a reconstruire

======================

17h: Injection + stockage anneau avec 160.4 I_dip anneau + HIGH Steerers horiz TL 
    recipe_recipe_LI_TL_RI_good_20250115_17_11_29.txt
    Cf screenshot stockage_50MeV_new_align.png


17h25 :  injection + stockage anneau
   1) sans steerer horiz
   2) et avec 159.3 dipoles anneau

        --> recipe_recipe_LI_TL_RI_good_20250115_17_28_10.txt
       
cf screenshots
          
stockage_50MeV_new_align_159_3_no_steerer.png
              tbtsum_compare_160_4_and_159_3-ring_dipole_2025-01-15_17-33-25.png
              ST3_storage_No_steerer_dipRING_159_3_2025-01-15_18-24-13.png
              BPM_TL_2025-01-15_17-52-24.png

fin de shift

 

Attachment 1: Screenshot_from_2025-01-15_11-43-33.png
Screenshot_from_2025-01-15_11-43-33.png
Attachment 2: stockage_50MeV_new_align.png
stockage_50MeV_new_align.png
Attachment 3: stockage_50MeV_new_align_159_3_no_steerer.png
stockage_50MeV_new_align_159_3_no_steerer.png
Attachment 4: tbtsum_compare_160_4_and_159_3-ring_dipole_2025-01-15_17-33-25.png
tbtsum_compare_160_4_and_159_3-ring_dipole_2025-01-15_17-33-25.png
Attachment 5: SST3_storage_No_steerer_dipRING_159_3_2025-01-15_18-24-13.png
SST3_storage_No_steerer_dipRING_159_3_2025-01-15_18-24-13.png
Attachment 6: BPM_TL_2025-01-15_17-52-24.png
BPM_TL_2025-01-15_17-52-24.png
Attachment 7: paramTL_no_steer_dipRING_159_3.png
paramTL_no_steer_dipRING_159_3.png
  1169   Mon Dec 15 08:06:26 2025 KD MJUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 15 décembre 2025 

8h: mise en chauffe en remote (chiller/frigo, laser, modulateur, cyclage)

* cannot enter to the ring with the recipe "40_MeV_Enough_Good_20251211_14_07_28", probably due to mis alignment procedure of the QP1-QP3.
* reset de TL steerers with the recipe "40MeV_20250401_15_09_50", first turn ok but no storage.
* steerers Ring to 0.

12h --> back to previous cathod point (last week tuning was done at that position)

  • TEST/HL/ThomX_PhotoCathode/Horizontal_Iris_Position_set : <type 'float'> : 4.714
  • TEST/HL/ThomX_PhotoCathode/Vertical_Iris_Position_set : <type 'float'> : 3.524

17h: essaie avec la recette initial de mardi "recipe_recipe_LI_TL_RI_all_20251209_17_54_51.txt"

==> difficile de retouver le TBTsum de mardi, ==> après quelques ajustements (rcds, etc). on retrouve quelques choses de passable

==> MRSV totalement différent: long, étalé et pas au même endroit (à droite au lieu d'être hors écran à gauche)

==> problème de répétabilité. La seule différence est la température de la section. 

 

*** Scan FPC table (~16h) - A l'oeil FWHM ~ 300 microns ==> rms ~ 128 ==> sig_ele_Vert ~ 107 ==> sig_Source_Vert ~ 60 microns

Bilan imagerie du jour :
tres bas flux et faisceau tres instable .==>  Pas de contraste de phase visible. On espere que demain sera mieux ! 

======================================================================================================

*** programme ***

Mesure imagerie X à basse énergie (40MeV)

 

  656   Thu Dec 15 13:11:15 2022 KDUnder ProcessShift summaryLI | Laser | Linac Commissionning shift du 15 decembre 2022, entered from 134.158.195.141 

12h : intervention casemate sur laser photocathode.

énergie mesurée sur différents points de fonctionnement :

Sortie Laser : 230uJ

Point de fonctionnement initial : position iris 5.82 / 3.59, ouverture 3 mm, attenuateur 410 mm
Sortie Transport Laser : 190uJ
Sortie Iris : 160uJ Injection canon : 120 uJ

Initial + Mouvement M4 : position Iris 5.42 / 5.39
Injection Canon : 120 uJ

Initial + Mouvement M5 : -50 pas moteur sur M5_MOT.02
Sortie TL : 190 uJ
Injection Canon 110 uJ

==> rien n'explique au niveau de la table PhotoCathode la baisse de charge des jours précédent.

Inspection du hublot d'entrée canon:
 * Hublot plein de poussières.
 * Nettoyage de la face avant du hublot (acetone + friction seche pour retirer les résidus de l'acetone). Il reste de la poussière sur la face arrière du hublot. ==> intervention nécessaire au niveau du hublot.
 * Pas d'impact laser visible sur la surface au niveau du spot laser (quelques goutes et rayure en bas du hublot)

Inspection du miroir de renvoie sous vide impossible.

13h20 : Démarrage faisceau

aucun écran SST et Laser accessible. Erreur dans lors du lancement :

Traceback (most recent call last): File "/data/shared/Interfaces/panneaux//Diags/interface_SST/IHM_SST.py", line 479, in master = SST_Control() File "/data/shared/Interfaces/panneaux//Diags/interface_SST/IHM_SST.py", line 127, in __init__ self.Image_camera = controled_image(save_path = self.attributs["SAVE_PATH"]) # nouvelle version File "/tmp_mnt/data/shared/Interfaces/panneaux/Diags/interface_SST/controled_image.py", line 331, in __init__ self.intensity_setting.setModel(synchro_tools.get_element_delay_tango_name("Diag",self.camera_delay_channel)) AttributeError: 'module' object has no attribute 'get_element_delay_tango_name'

13h25 : mesure de charge Max

Position iris 5.82 / 3.59 : 69pC
Position iris 5.42 / 3.59 : 140pC
Position iris 5.02 / 3.59 : 180pC

==> problème lors de l'injection dans le canon.

  Draft   Tue Apr 15 08:10:35 2025 KDUnder ProcessShift summaryDiag | Laser | Opt | Linac Commissionning | Ring Commissioning shift du 15 avril 2025 

8h10 : mise en chauffe de la machine à distance (modulateur, chiller/frigo, cyclage)

* redémarrage des DS client5

* impossible de lancer le laser (il faut intervenir en local)

*  8h40 Timing opérationnel à 10Hz

  1137   Tue Oct 14 08:00:18 2025 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 14 octobre 2025 

7h55: mise en chauffe en remote (laser, frigo/chiller, modulateur, cyclage)

==> Nouvelle interface de cyclage, on ne voit plus la progression ou l'état des éléments. (impossible de savoir si le cyclage à bien fonctionné)

10h: recette chargée 50MeV 20251010_15_48_41

Commentaires machine :

* pour un bon stockage l'énergie n'est pas bonne (157.3A sur TL/DP pour etre à 0 TL/BPM.02), position vertical TL/BPM.02 ~ -4mm (stockage possible avec +- 2A sur TL/DP)

/!\ l'orbite n'est pas "flat" à l'IP (comparaison avec chargement de la recette "50MeV_100pC_flatVERTorbit_withEL_20250717_10_58_38.txt"), l'orbite n'est plus "plate" avec l'ancienne recette. 

* probleme dans la EL, le faisceau n'est pas extrait correctement avec la nouvelle recette. 

/!\ probleme BPM/EL, le BPM n'affiche plus la position du faisceau !

* comparaison orbite du matin et de l'après midi, l'orbite change en X pas en Y.

* décalage du délais septum de 4us pour mettre l'impulsion des kicker à peu pres au sommet de l'impulsion ==> il faut désendre le septum de ~ 2V dans ce cas (97.13V --> 95.33V)

** recette sauvée sous : 50MeV_100pC_MRSV_20251014_18_22_53

 

* mise à jour du DS "DS_Ring_RF" pour faire les changement de fréquence anneau et phase au meme endroit.

 

*** Prise de donnée ***

- échantillon chocolat : le plus riche en Cd ne fait pas appaitre de pics !

- Nb présent dans échantillon d'un patien "sain". 

 

Attachment 1: Capture_d’écran_2025-10-14_075918_IHM_cycling.png
Capture_d’écran_2025-10-14_075918_IHM_cycling.png
Attachment 2: BPM_p2A_TL_DP.png
BPM_p2A_TL_DP.png
Attachment 3: orbit_20251014_10h00.png
orbit_20251014_10h00.png
Attachment 4: orbit_20251014_VS_flatorbit_20250717.png
orbit_20251014_VS_flatorbit_20250717.png
Attachment 5: extraction_BPM.png
extraction_BPM.png
Attachment 6: probleme_BPM_EL.png
probleme_BPM_EL.png
Attachment 7: kickers_septum.png
kickers_septum.png
Attachment 8: orbit_20251014_18h00.png
orbit_20251014_18h00.png
ELOG V3.1.4-395e101