ID Date Author Status Typedown Category Important Subject Icon
  1247   Tue Jun 16 13:43:30 2026 Entered by Super Team from 127.0.0.1 on Tue Jun 16 13:43:02 2026 FixLI   

Hello,

I short-circuit the MPS input to modulator, we can trig modulator, the klystron filmant time goes to full time  icon9.gif , need 45 min, you can start at 14:35

Maher

  265   Thu Jan 20 10:38:21 2022 Entered by Super Team from 134.158.195.142 on Thu Jan 20 10:38:05 2022Under ProcessCavite optiqueLinac Commissionning intervention FP 

intervention alignement cavité en cours, faisceau impossible

  Draft   Fri Sep 17 09:12:29 2021 Entered by mohamed el khaldi from 134.158.76.146 on Fri Sep 17 09:12:06 2021FixedAnneau  Tuning des HOM's de la cavité RF anneau en stand by aprés les coupures d'électricité  

le tuning automatique des HOM's de la cavité RF anneau fonctionnait bien avant les coupures d'éléctricité.

à mon retour des vacances je voulais reprendre les tests mais en vain

deux hypothéses se présentent:

1/ soit le hardware (carte redpitaya) est en panne ( la fonction de conversion analogique-numérique n'est plus possible) : nous voulons vérifier le hardware mais les tests devraient se faire sous Tango ==> besoin d'assistance de CC

NB:  meme si on veut utiliser une carte spare pour vérifier,  on a un souci il faut que la carte spare soit configurée avec une adresse IP qui dépend de son adresse MAC  ( faire le ticket ==> il faut prévoir min une semaine pour avoir une adresse IP) ==> solution soit anticiper la configuration des spares sous le réseau bien avant  sinon on perd beaucoup de temps pour ces manips qui pourraient se résoudre en une heure) ou proposer une  autre solution (adresse IP doit etre attribué automatiquement au composant possédant une adresse MAC)

2/ soit problème de Software (DS carte redpitaya: ER/RF/RAC.14-ELR.01-RDP.01) ==> le DS met 0 v sur la lecture (channel "A" indique toujours 0 V) même si la tension à la sortie de comparetur de phase varie ===> besoin d'assitance de CC

je vais faire un ticket espérant une intervention rapide

  197   Thu Dec 2 10:38:44 2021 Entered by Maher OMEICH from 134.158.91.212 on Thu Dec 2 10:38:07 2021 AnneauAimants intervention Soleil 

Bonjour, Patrick Alexandre et Didier Muller ( Soleil ) viendrons demain Vendredi 03/12 toute l'après midi, j'aurai plus d'info aujourd'hui concernant la journée de la semaine prochaine.

  200   Mon Dec 6 11:30:53 2021 Entered by Maher OMEICH from 134.158.91.212 on Mon Dec 6 11:30:27 2021Under ProcessAnneauAimants Tests EPs  

Bonjour, demain mardi 07/12 sera une journée casemate ouverte pour les tests des éléments pulsées ( kikers .... )

 

  219   Thu Dec 16 09:35:11 2021 Entered by Super Team from 134.158.195.141 on Thu Dec 16 09:34:53 2021FixedAnneauSY éléments pulsés 

Réglage des largeurs d'impulsion pour les kickers d'injection:

GENERATOR_2_CHANNEL_1: 'Ring pulsed injection'
GENERATOR_2_CHANNEL_2: 'Ring pulsed extraction'
GENERATOR_2_CHANNEL_3: 'Ring pulsed septum'

ATTENTION CES VALEURS NE DOIVENT PAS ETRE CHANGEES SOUS PEINE D'ENDOMMAGER LE MATERIEL!!!!!!

 

  473   Tue Jun 7 17:23:59 2022 NDUnder ProcessAnneauAimants Test cycling QP anneau 

Test de l'IHM de cyclage des aimants de l'anneau

- l'IHM fonctionne (teste uniquement pour QP)

Defaut (internal interlock hard) sur RI-C1/PS/QP.05,RI-C1/PS/QP.06,RI-C2/PS/QP.02

Cyclage des autres QP OK.

 

  578   Thu Oct 6 10:18:03 2022 VK/ND/SC AnneauRing Commissioning Faisceau Anneau 

Modulateur Impossible à passer en Standby ==> problème manque d'eau.

      * Remise à ~4bars le réseau principal

      *  Restart du soft du modulateur (sinon l'erreur reste)

      * Conductivité à 7MOhm

10h : Démarrage modulateur et refroidissement (MO)

Modulateur 1090V, Mise en place du feedback position laser

Scan charge phase avec iris à 4 mm, phase de charge max phi = 366 degres

Iris 4 mm  Qmax sur LI/SST.01 = 80.7 pC std 14.2

Iris 3 mm Qmax = 64.6 std 14.2 pC

Iris 2 mm Qmax = 32.4 std 11.2 pC

Iris 1 mm Qmax = 10.4 std 11.9 pC

Mesure energie avec les steerers : 52 MeV

Chargement recette du vendredi 30/09 (19-22-04)

-------------------------------------------------------------------------------------------------------------

Problème licence matlab :

Warning: Directory already exists. 
> In quad_TLSST1_thomx_Dark_dim_bary_v3 (line 87) 
License checkout failed.
License Manager Error -4
Maximum number of users for Image_Toolbox reached.
Try again later.

Troubleshoot this issue by visiting:
https://www.mathworks.com/support/lme/R2018b/4

Diagnostic Information:
Feature: Image_Toolbox
License path: /data/operateur.thomx/.matlab/R2018b_licenses:/home/debian/R2018B/licenses/license.dat:/home/debian/R2018B/licenses/network.lic
Licensing error: -4,132.

Error in quad_TLSST1_thomx_Dark_dim_bary_v3 (line 154)
        h1=drawrectangle('Position',[length(K(1,:,1))/2-50 length(K(:,1,1))/2/2-50 50 50]);pos = round(customWait(h1));% position signal

-------------------------------------------------------------

Faisceau pour anneau

Ouverture iris 2 mm (25 pC environ)

Ouverture iris 4 mm Qenergie max = 66 pC (phi energie max = 216)

Ok pour injection et tours dans l'anneau

Sauvegarde recette recepe_LI_TL_RI

 

13h13 Recipe saved for the ring. Injection optimised.

14h Camera MRSV non accessible => a verifier dans la casemate

14h05 etude de l' effet de l' iris laser sur LI/DG/BPM.01. Les 4 copies d'ecran correspondent a 4 valeurs d'iris different de 4mm a 1mm.

16h Etude systematique de la position sur LI/DG/BPM.01 vs iris. Cf images jointes.

L'attenuation etait trop forte, a basse charge (iris ferme) la position etait domine par le bruit.

Si l 'attenuation est trop forte (32dB), les mesures saturent. Il faut regler l 'attenuation de LI/DG/BPM.01 a -15dB.

Étude similaire sur TL/DG/BPM.01. Cf images jointes. Il faut regler l 'attenuation de TL/DG/BPM.01 a 0dB.

Arret machine 16h26.

Note: RI-C2/DG/MRSV n'était pas branché. Il va falloir se procurer les câbles correspondants.

 

 

 

Attachment 1: Screenshot_from_2022-10-06_14-05-37.png
Screenshot_from_2022-10-06_14-05-37.png
Attachment 2: Screenshot_from_2022-10-06_14-05-52.png
Screenshot_from_2022-10-06_14-05-52.png
Attachment 3: Screenshot_from_2022-10-06_14-06-26.png
Screenshot_from_2022-10-06_14-06-26.png
Attachment 4: Screenshot_from_2022-10-06_14-06-45.png
Screenshot_from_2022-10-06_14-06-45.png
Attachment 5: bpm_0_Att_31.0_vs_iris.png
bpm_0_Att_31.0_vs_iris.png
Attachment 6: bpm_0_Att_15.0_vs_iris.png
bpm_0_Att_15.0_vs_iris.png
Attachment 7: bpm_0_Att_0.0_vs_iris.png
bpm_0_Att_0.0_vs_iris.png
Attachment 8: bpm_1_Att_0.0_vs_iris.png
bpm_1_Att_0.0_vs_iris.png
Attachment 9: bpm_1_Att_15.0_vs_iris.png
bpm_1_Att_15.0_vs_iris.png
Attachment 10: bpm_1_Att_31.0_vs_iris.png
bpm_1_Att_31.0_vs_iris.png
  598   Thu Oct 20 08:56:39 2022 SC, ND AnneauDiag Shift du 20/10/2022 

8h56 Démarrage modulateur et refroidissement

9h20: git pull => mise a jour des IHM SST et BPM (git pull qui n'avait pas ete fait cette semaine)

10:05 Demarrage Scan charge phase

10:13 Interlock. Intervention CTA?

10:15 Charge max: Phase=260 => Energy max: Phase=210 Charge ~85pC (Iris=1.3mm)

11:13 Chargement recette recipe_recipe_LI_TL_20221018_14_30_21.txt

11:19 Chargement recette Saturation_TL_SST1_recipe_LI_TL_straight_20221018_11_49_54

Observation faisceau sur LI/SST.1 => Max intensity = 2000

Optimisation solenoide

Observation faisceau sur LI/SST.1 => Max intensity = 4000

11:30 Intervention RedPitaya. La permutation s'est bien passee. La RDP doit maintenant etre mise dans son chassis.

12:00 Etude saturation ecrans

Pas de saturation quand on reduit l'intensite (cf images jointes).

50% sur LI/SST.01

10% sur TL/SST.01

12:24 Chargement recette recipe_recipe_LI_TL_20221018_14_30_21.txt

Q(TL/DG/ICT2)=70pC

Pas de saturation sur TL/SST.2

 

 

Attachment 1: scan_charge_phase_min_0.0_max_360.0_10_9_12.png
scan_charge_phase_min_0.0_max_360.0_10_9_12.png
Attachment 2: scan_charge_phase_min_230.0_max_280.0_10_15_56.png
scan_charge_phase_min_230.0_max_280.0_10_15_56.png
Attachment 3: Screenshot_from_2022-10-20_11-56-48.png
Screenshot_from_2022-10-20_11-56-48.png
Attachment 4: Screenshot_from_2022-10-20_11-57-21.png
Screenshot_from_2022-10-20_11-57-21.png
Attachment 5: Screenshot_from_2022-10-20_11-57-34.png
Screenshot_from_2022-10-20_11-57-34.png
Attachment 6: Screenshot_from_2022-10-20_11-57-49.png
Screenshot_from_2022-10-20_11-57-49.png
Attachment 7: Screenshot_from_2022-10-20_12-00-41.png
Screenshot_from_2022-10-20_12-00-41.png
Attachment 8: Screenshot_from_2022-10-20_12-01-49.png
Screenshot_from_2022-10-20_12-01-49.png
  617   Fri Oct 28 09:19:22 2022 SC/ND AnneauLinac Commissionning Démarrage faisceau et TP 

9h19 : Mise en route modulateur et refroidissements

10h45: Start the Modulator

11h30 : Scan charge
Max chage : 238°
Max energy : 188°

12h : load recipe : recipe_recipe_LI_TL_RI_20221021_16_15_04.txt
Dipole TL switch off -> Beam on TL/DG/SST.01

12h30 : Dipole TL switch on
Beam on TL/DG/SST.02
Beam energy and enegy spread improved by increase phase to 204 (cf image) (dipoles at 156A)

12h45 : Injection dans l'anneau
calcul convetion A -> rad for kicker

13h50:
Test on TL/DG/SST.02


 

===

Program for the shift on 28/10

1) Start beam

2a) Measure respone of TL/SST.2  as function of time

2b) Try to put TL/SST2 on negative polarity

3) Study BPM attenuation

4) Test Alexandre's feedback

5) Cerenkov

Attachment 1: scan_charge_phase_min_200.0_max_280.0_12_4_46.png
scan_charge_phase_min_200.0_max_280.0_12_4_46.png
Attachment 2: 2022-10-28_12_39_29_tl_dg_sst_02-ccd_01_RAW.png
2022-10-28_12_39_29_tl_dg_sst_02-ccd_01_RAW.png
  649   Fri Dec 9 11:07:57 2022 Entered by Super Team from 134.158.195.141 on Fri Dec 9 11:07:40 2022Under ProcessAnneauRing   

Phase Qmax = 138

Phase Emax = 88

energy jitter

RF Cavity interlock vacuum - reset with DS .

Search optimal phase of RF cavity.

 

16:50 Closing the scrapper: less losses at injection

Best scrapper setting L=35mm R=9mm

17:30 Demarrage Kicker extraction

Pelser3fault and Pulser4fault on Extraction Kicker => Impossibele to start

 

 

 

 

Attachment 1: Screenshot_from_2022-12-09_16-53-05.png
Screenshot_from_2022-12-09_16-53-05.png
Attachment 2: Screenshot_from_2022-12-09_16-52-44.png
Screenshot_from_2022-12-09_16-52-44.png
  666   Thu Jan 12 08:55:33 2023 SC/ND/IC/VK/VM AnneauRing Commissioning Faisceau  

Mise en chauffe modulateur et refroidissements

Résistivité : 3.53 MOhm et Pression eau : 3.7

9:40: Cyclage des aimants. Problemes habituels.

10:20 Beam ON

10:30 Scan charge phase

10:40 Chargement recette LI+TL 05/01 11h07

10:44 Chargement recette 11/01 17h31 LE non optimum

Phase section: 118 degrees

Faisceau bien centre sur TL/DG/SST.02 mais bouge beaucoup (cf images)

11:10 Reglage des fentes (15mm;25mm)

 

TL/DG/SST.03: Le faisceau bouge de 0.2 tache focale.

Tentative d 'injection dans la ligne d 'extraction: cela ne marche pas.

 Explication de Hayg: il faut aussi aller EL/PS/DPI qui n'etait pas dans la recette.

Le changement d' energie du faisecau pose probleme pour l'anneau: nous devons tout reajuster.

 

Tentative de chargement des recette anneau precedentes.

 

Nouvelle valeur pour RI-C1/PS/DP.01: 176.42A

 

13:25 RF section phase is now 111

Nouveau reglage des fentes: 10;34mmm

 

Apres midi: Tentative de stockage du faisceau sans succes...

Sur health check: le laser est passe en rouge.

17h57 Machine OFF

 

Attachment 1: Screenshot_from_2023-01-12_10-14-16.png
Screenshot_from_2023-01-12_10-14-16.png
Attachment 2: scan_charge_phase_min_0.0_max_360.0_10_42_52.png
scan_charge_phase_min_0.0_max_360.0_10_42_52.png
Attachment 3: scan_charge_phase_min_215.0_max_235.0_10_43_15.png
scan_charge_phase_min_215.0_max_235.0_10_43_15.png
Attachment 4: dispersion_10_53_55.png
dispersion_10_53_55.png
Attachment 5: 2023-01-12_11_02_15_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_1000.png
2023-01-12_11_02_15_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_1000.png
Attachment 6: 2023-01-12_11_01_07_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_4000.png
2023-01-12_11_01_07_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_4000.png
Attachment 7: 2023-01-12_11_09_21_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_1000.png
2023-01-12_11_09_21_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_1000.png
Attachment 8: 2023-01-12_11_10_11_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_1000.png
2023-01-12_11_10_11_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_1000.png
Attachment 9: dispersion_13_17_51.png
dispersion_13_17_51.png
Attachment 10: 2023-01-12_13_29_17_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_100.png
2023-01-12_13_29_17_tl_dg_sst_02-ccd_01_log_scale_False_despeckle_False_min_scale_0_max_scale_100.png
Attachment 11: Screenshot_from_2023-01-12_17-55-01.png
Screenshot_from_2023-01-12_17-55-01.png
  668   Fri Jan 13 17:25:33 2023 NDUnder ProcessAnneauAimants Test cyclage aimants 

17h25: Test de cyclage de

RI-C1/PS/QP.05

RI-C1/PS/QP.06

RI-C2/PS/QP.02

 

Resultats

RI-C1/PS/QP.05

RI-C1/PS/QP.06: Failed at 11% when magnet reached 10A => Ne pas cycler au dela de 9.4A

RI-C2/PS/QP.02: Failed at 11% when magnet reached 10A=> Ne pas cycler au dela de 8.5A

  669   Wed Jan 18 14:02:39 2023 ICUnder ProcessAnneauAimants RE: Test cyclage aimants 

I have decresed the Imax to 8 A and loaded the new cycling curves

RI-C1/PS/QP.06 and RI-C2/PS/QP.02: normally cycling  with Imax 8 A , finish without error => PS to be checked for Imax >8 A (nominal 10 A

ND wrote:

17h25: Test de cyclage de

RI-C1/PS/QP.05

RI-C1/PS/QP.06

RI-C2/PS/QP.02

 

Resultats

RI-C1/PS/QP.05

RI-C1/PS/QP.06: Failed at 11% when magnet reached 10A => Ne pas cycler au dela de 9.4A

RI-C2/PS/QP.02: Failed at 11% when magnet reached 10A=> Ne pas cycler au dela de 8.5A

 

Attachment 1: cylage_quad8A.png
cylage_quad8A.png
  818   Thu Nov 16 08:52:14 2023 SC/IC/JNC/VK/HG/VM AnneauLI | LE | Ring Faisceau anneau point de fonctionnement 

8h52 : mise en chauffe modulateur et chillers, cyclage des aimants

10h15 : Le laser n'est pas centré dans l'iris malgré le feedback

Modification de M5 à la main car non centré dans l'iris malgré le feedback (xposition 38 à 98), yposition non modifiée : 96 prise d'images

10h33 scan charge phase, charge environ 100 pC

Chargement de la recette

Re-réglage linac phase attenuateur etc.... pour arriver à injecter

Faisceau pas à la bonne énergie au départ

Injection faisceau dans l'anneau, problème avec la cavité RF : pas de puissance

Injection anneau

Modulateur à 1090V au lieu de 1100V parce que la position sur apres dipole BPM2LIB2 saut de 4 mm-5mm ensuite le signal sur bpm était mieux et linjection plus stable (difficile distanguer de cout manques).

C'est un problème pour injection et stockage dans l'anneau

A regarder pour résolution du problème avec l'équipe RF ?

Point de fonctionnement identique au 24/10 sauf le soleno qui est à 220A au lieu de 180A.

En regardant moniteur d'injection (screenshot), on peut penser que les sauts sont corrélés aux sauts obervés sur BPM2-TL2. Ils sont aussi corrélés à une mise à zéro des icts.

Prise de données anneau

Comportement etonnant du faisceau à 16h25 environ, apparition de signaux incohérent sur ICT

16h27 Perte du faisceau (cf screenshot de la charge) + Interlock sur la cavité RF + modification de l'énergie du faisceau nécessaire de bouger la valeur de l'attenuateur pour retrouver le faisceau en sortie de ligne de transfert.

16h50 Reprise de la prise de donnée anneau, redémarrage de la cavité RF (JNC), nouvelle valeur atténuateur section (1.7 à 1.5 dB environ = variation d'énergie)

Observation d'un saut de phase sur oscilloscope qui pourrait expliquer

16h58 A nouveau modification du comportement du faisceau, perte de charge sur ICT3, modification de la position du faisceau sur bpm2lib2, Changement de la position du faisceau sur tl/bpm2lib2,

Faisceau revenu à la normale on ne sait pas pourquoi

17h30 Arret faisceau

 

 

 

 

 

 

Attachment 1: Screenshot_from_2023-11-16_14-48-02.png
Screenshot_from_2023-11-16_14-48-02.png
Attachment 2: Screenshot_from_2023-11-16_14-49-27.png
Screenshot_from_2023-11-16_14-49-27.png
Attachment 3: Screenshot_from_2023-11-16_16-40-05.png
Screenshot_from_2023-11-16_16-40-05.png
  822   Thu Nov 23 08:51:44 2023 SC/KD AnneauLI | TL | LE | Ring Faisceau LE 

8h50 Mise en chauffe modulateur

Mise en route chillers et frigo

Problème laser photocathode : en cours d'investigation par Kevin et Viktor

10h Résolution problème laser nécessaire, arret modulateur, chillers et frigo

 

  Draft   Thu Jan 23 17:03:45 2025 Ring team AnneauRing Commissioning Ring Working Points 50 MeV/ 61.5 MeV / 70 MeV 

50 MeV

Configuration: good_20250123_17_53_01 "Working Point at 50 MeV for X_rays"

After RCDS optimization with X-rays good_20250124_15_05_25 "Updated WP with RCDS on X-rays 50 MeV "

Update from 14/02/2025 => Configuration: good_20250214_14_21_55 "50 MeV WP 120 um"

RF Frequency: 500.10045 MHz (33.XXXX MHz)

Vertical size of the interation region: 124 um =>laser beam size: 75 um (assumed); electron beam size : 99 um

Beam orbit:

BPM around IP

BPM3 ri-c1/dg/bpm.04-lib.03: x= 0.6 mm y = -2.87 mm

BPM4 ri-c1/dg/bpm.05-lib.04: x= 0.5 mm y = -2.96 mm

After RCDS

BPM3 ri-c1/dg/bpm.04-lib.03: x= 0.6 mm y = -0.18 mm

BPM4 ri-c1/dg/bpm.05-lib.04: x= 0.3 mm y = 1.88 mm

 

RF gun 231 deg. Sect. Att. set to 2.43 dB, Sect. phase is 209 dg. TL/DP current set to 159.3 A, Linac steerers H [1.16 -3.2], V [-2.25 2.86] ; TL BPM2 x =  mm

Run with FPC P= 89 kW

X-ray intensity (synchronized mode): max 50000 pA ~2-3x10^10 ph/s

61.5 MeV

Configuration: good_20250214_16_29_22 "61.5 WP 177 um"

RF Frequency: 500.04545 MHz (33.XXXX MHz)

 

70 MeV

RF Frequency: 500.03165 MHz (33.XXXX MHz)

Att 0.3 dB

40 MeV

40 MeV. Sect. Att. set to 4.095 dB, Sect. phase is 205 dg. TL/DP current set to 125.38 A, Linac steerers H [1.19 -3.25], V [-3.05 3.47]

TL BPM 20= -2 mm

RF cavity 50 kV, Freq=500.11896 MHz

RF Frequency: 500.11851 MHz (33.341230 MHz)

Vert FPC scan : IP region 0.199 um

X ray flux asynch I3 ~ 370 pA (background level 310-315 pA)

43.7 MeV

RF gun 162 deg. Sect. Att. set to 3.51 dB, Sect. phase is 210 dg. TL/DP current set to 136.95 A, Linac steerers H [0.44 -2.77], V [-2.36 2.87]

TL BPM 20= -1.5 mm

RF Frequency: 500.1189 MHz

35 MeV

RF gun 162 deg. Sect. Att. set to 4.98 dB, Sect. phase is 202 dg. TL/DP current set to 111.3 A, Linac steerers H [], V []

TL BPM 20= -1.5 mm

RF Frequency: 500.1189 MHz

 

Attachment 1: Screenshot_from_2025-01-23_17-35-51.png
Screenshot_from_2025-01-23_17-35-51.png
Attachment 2: Screenshot_from_2025-01-23_17-34-36.png
Screenshot_from_2025-01-23_17-34-36.png
Attachment 3: VerticalScanFPC_23012025.png
VerticalScanFPC_23012025.png
Attachment 4: First100turns_23012025.png
First100turns_23012025.png
Attachment 5: BPMsigma_23012025.png
BPMsigma_23012025.png
Attachment 6: closed_orbit_23022025.png
closed_orbit_23022025.png
Attachment 7: Screenshot_from_2025-01-24_15-17-46_after_RCDS.png
Screenshot_from_2025-01-24_15-17-46_after_RCDS.png
Attachment 8: closed_orbit_updateRCDS_24012025.png
closed_orbit_updateRCDS_24012025.png
  Draft   Thu Jul 1 10:12:11 2021 Entered by Nicolas Delerue from 134.158.89.243 on Thu Jul 1 10:11:03 2021Not Fixed   , entered from 134.158.89.243 
  Draft   Mon Oct 18 11:26:58 2021 Entered by Super Team from 134.158.195.142 on Mon Oct 18 11:26:41 2021    Shift condionnement RF : passage à 5Hz 
  Draft   Mon Oct 25 19:23:51 2021 Entered by Super Team from 134.158.195.142 on Mon Oct 25 19:23:35 2021    , entered from 134.158.195.142 

Passage de la sect