Entered by Nicolas Delerue from 134.158.195.144 on Thu Mar 24 10:34:03 2022; config clefs PSS
|
Operateurs: VC, SC, ND
Pour memoire, cf photo... |
Entered by Nicolas Delerue from 134.158.195.144 on Thu Mar 24 09:43:47 2022; Mesures 24/3/2022
|
Operateurs: ND, VC, SC
===
|
Entered by Nicolas Delerue from 134.158.195.144 on Thu Jan 9 10:30:34 2025; DS ThomX_PhotoCathode using a lot of CPU 
|
The load on client5 is 29 making all operations slow.
Appently the DS ThomX_PhotoCathode is using a lot of CPU, slowing the rest.
|
Entered by Nicolas Delerue from 134.158.195.144 on Fri Nov 15 12:13:26 2024; Charge excess in the TL 
|
By looking at the BPM transmission tool one can see that there is more charge on TL/BP.03 than on TL/BPM.02 (see attached image).
The BPM seetings have been checked and they are similar.
One can see a similar effect when comparing TL/ICT.01 and TL/ICT.02. |
Entered by Nicolas Delerue from 134.158.195.142 on Tue Nov 21 14:28:47 2023; Prise de donnees 21/11
|
13:57 Mise en chauffe
15:00 Faisecau
Tests sur les ecrans |
Entered by Nicolas Delerue from 134.158.195.142 on Thu Feb 16 10:51:56 2023; Health check
|
Les erreurs severes dans health check ont ete resolues.
La plupart etaient solvable en suivant les instructions donnees par health check.
La seule erreur plus compliquee etait sur TL/PS/DPI ou il a fallu aller valider (ack) l'erreur en local. |
Entered by Nicolas Delerue from 134.158.195.142 on Fri Feb 24 16:24:00 2023; Shift 24/2
|
13:30 Mise en chauffe
14:30 Demarrage faisecau
Test de modifications de diverses interfaces. |
Entered by Nicolas Delerue from 134.158.195.142 on Fri Dec 20 13:59:52 2024; Alarme sur les rondes
|
A 13h30 j'ai tent'e de faire un acces controle dans la casemate.
Quand j'ai pris la 1ere clef une alarme (son inhabituel) s'est declenchee au niveau de la fosse sud avec un chenillard rouge sur les
verrines (fooses nord, sud et klystron). |
Entered by Nicolas Delerue from 134.158.195.141 on Tue Jan 11 19:30:03 2022; Pb declenchement scope synchro
|
La frequence des diags etait reglee a 0.1Hz et le scope de la salle de controle se declenchait sur les diags. C'est pour cela que le scope se declenchait
toutes les 10s.
Les signaux en salle de controle ont une longueur de 10ms mais ceux distribues ont les largeurs demandees (20us et 10us respective,ent pour les |
Entered by ND/VC/HG/SC from 134.158.195.142 on Thu Mar 24 17:11:44 2022; Paramètres Faisceau
|
Alignement laser
On retrouve la phase pour la charge max phi = 313 degres (consigne chiller canon = 31.25 degres)
On enlève 40 degres à la phase de charge max pour arriver à la phase d'énergie maximum phi = 273 degres |
Entered by ND/VC/HG/SC from 134.158.195.142 on Thu Mar 24 15:41:04 2022; Alignement laser 
|
Position moteur M4 avant alignement laser :
x = 380 et y = 5373
Position moteur M4 après alignement laser : |
Entered by ND/SC from 134.158.195.141 on Tue Jun 21 09:58:15 2022; Demarrage et faisceau 12x
|
9h45 Mise en chauffe modulateur. Test interface générale Nicolas pour l'allumage du modulateur.
11h00 Cyclage dipole anneau en cours. Cyclage TL/PS/DP.01 impossible. External error.
11h18 Mise en route chillers via interface generale pour tests |
Entered by ND/SC from 134.158.195.141 on Tue Jun 21 09:58:15 2022; RE: Demarrage et faisceau 
|
La même chose avec le signal des BPM en plus.
Entered
by ND/SC from 134.158.195.141 on Tue Jun 21 09:58:15 2022 wrote:
9h45 Mise en chauffe |
Entered by ND/JNC/VC/VS/MO/SC from 134.158.195.141 on Tue Jun 7 09:52:47 2022; Etat des lieux
|
Presents: SC, ND, JNC, VS, MO
Fermeture casemate
Tests des DSs en cours |
Entered by Moutardier from 134.158.76.123 on Tue Dec 1 09:56:35 2020; Verrification pour le démarrage a blanc
|
Verification de l'état de la Synchro : OK, tout les signaux sont en trigger externe.
Verification de l'état des diagnostiques :
- Libera 3 : n'est pas encore cofiguré (pas génant pour le démarrage a blanc) |
Entered by Moutardier Alexandre from 91.168.92.148 on Thu Dec 16 14:58:26 2021; Alimentation en état FAULT !!!
|
D'après health_check toutes les alimentations electrique des solenoides, deviateur et quadrupole sont en état FAULT.
Est ce que quelqu'un présent sur place pourrait aller voir pourquoi ? |
Entered by Moutardier Alexandre from 91.168.92.148 on Thu Dec 16 10:39:49 2021; test en ssh
|
| Connection ssh sur client4 pour tester une modification de health_check |
Entered by Moutardier Alexandre from 91.168.92.148 on Thu Dec 16 10:39:49 2021; RE: test en ssh
|
Modifications faites, testées et fonctionnelles.
Entered
by Moutardier Alexandre from 91.168.92.148 on Thu Dec 16 10:39:49 2021 wrote:
Connection |
Entered by Moutardier Alexandre from 193.55.29.170 on Mon Jan 10 09:26:50 2022; Automatique "health check"
|
Allumage de client 5. Pourquoi était-il éteint sachant qu'il y a des ds qui doivent tourner dessus ?
Lancement du processus de mise a jour automatique de l'état de la machine (health_check) sur client 5.
En cas de soucis le bouton "Force update" permet de lancer une procédure de verification de l'état de la machine manuellement. |
Entered by Moutardier Alexandre from 134.158.195.145 on Fri Sep 9 18:26:38 2022; First injection in the ring 
|
Injection dans l'anneau.
Signaux sur les 5 premier BPM de l'anneau without kicker.
(Attention, le premier BPM vu par le faisceau est RI-C1/DG/BPM.02) |