  Toutes les notes concernant les Commissionning de ThomX, Page 4 of 62  Not logged in ThomX    logo
ID Date Author Statusdown Type Category Important Subject Icon
  139   Thu Oct 28 17:13:35 2021 Entered by sophie chance from 134.158.195.141 on Thu Oct 28 17:13:21 2021Under ProcessLinacDiag BPMs 

Passage à 1 Hz pour transport faisceau avec bobine de foc pour test sur les BPMs en bougeant les steerers

  143   Fri Oct 29 11:19:51 2021 Entered by sophie chance from 134.158.89.243 on Fri Oct 29 11:19:37 2021Under ProcessProblemLinac Commissionning Problème modulateur 

Scandinova a été contacté, pas de retour pour l'instant.

Harware reset pour voir si cela améliore les choses pour la suite de la journée en attendant la réponse de scandinova

En chauffe pour l'instant.

  144   Fri Oct 29 13:32:18 2021 Entered by sophie chance from 134.158.195.142 on Fri Oct 29 13:32:05 2021Under ProcessInfoLinac Commissionning Mise en route du faisceau 

Le modulateur est en route, nous nous replacons à la même position qu'hier 0.25dB attenuation, 10 Hz, attenuation section à 27 dB, observation sur SST.01 après canon

Interlock à partir de 160 A sur le vide, charge à environ 40 pC qui correspond plutot à un presque maximum d'énergie pour une phase de 263 degres (I = 160 A)

  145   Fri Oct 29 13:57:49 2021 Entered by sophie chance from 134.158.195.142 on Fri Oct 29 13:57:22 2021Under ProcessLinacLinac Commissionning Passage section 

Le faisceau a passé la section

STR01-V01 = -1.10, STR01-H01 = -1.90

Ifoc = 150A, phase 263, 1.5 dB section, 0.25 dB canon

 

Attachment 1: Passage_section_291021.png
Passage_section_291021.png
  Draft   Fri Oct 29 15:56:01 2021 Entered by Super Team from 134.158.195.142 on Fri Oct 29 15:55:48 2021Under ProcessQuestion  Erreur DS CALC 

 

alexandre.moutardier@client3:~/git/panneaux/PlateformeIHMThomX$ ****************************** motor_position 0 1.0 1
jiji  406.6361292814322
****************************** motor_position 0 3.25 1
jiji  706.627460299649
****************************** motor_position 0 3.0 1
jiji  683.2899425352272
****************************** motor_position 0 1.25 1
jiji  459.5732341444216
****************************** motor_position 0 1.25 1
jiji  459.5732341444216
*****Error set attenuatation value  ***** motor_position 0 1.25 1
Error set attenuatation value  459.5732341444216
****************************** motor_position 0 0.25 1
jiji  195.89278026310274
****************************** motor_position 1 10.0 1
jiji  1101.9935039664515
****************************** motor_position 1 5.0 1
jiji  860.9899259598128
****************************** motor_position 1 1.5 1
jiji  505.4962801007356
****************************** motor_position 0 0.5 1
jiji  285.54820384824495
****************************** motor_position 0 0.75 1
jiji  348.5528535034814
*****Error set attenuatation value  ***** motor_position 0 0.75 1
Error set attenuatation value  348.5528535034814
****************************** motor_position 0 0.25 1
jiji  195.89278026310274
*****Error set attenuatation value  ***** motor_position 0 0.25 1
Error set attenuatation value  195.89278026310274
alexandre.moutardier@client3:~/git/panneaux/PlateformeIHMThomX$ ****************************** motor_position 0 0.5 1
jiji  285.54820384824495
****************************** motor_position 0 0.5 1
jiji  285.54820384824495
****************************** motor_position 0 0.75 1
jiji  348.5528535034814
****************************** motor_position 0 0.75 1
jiji  348.5528535034814
*****Error set attenuatation value  ***** motor_position 0 0.75 1
Error set attenuatation value  348.5528535034814
****************************** motor_position 0 1.0 1
jiji  406.6361292814322
*****Error set attenuatation value  ***** motor_position 0 1.0 1
Error set attenuatation value  406.6361292814322
****************************** motor_position 0 1.0 1
jiji  406.6361292814322
*****Error set attenuatation value  ***** motor_position 0 1.0 1
Error set attenuatation value  406.6361292814322
****************************** motor_position 0 1.25 1
jiji  459.5732341444216
*****Error set attenuatation value  ***** motor_position 0 1.25 1
Error set attenuatation value  459.5732341444216

  151   Mon Nov 8 09:21:48 2021 Entered by sophie chance from 134.158.195.141 on Mon Nov 8 09:21:32 2021Under ProcessInfoDiag | Aimants | CC | Infra | Laser | Opt | RF D1 | RF Anneau | MECA | SY | Vide | Electronique | Linac Commissionning Etat des lieux  

SC et AM

Fermeture des sous-sols et de la crinoline

Login sur les clients 1 et 2 sur le compte opérateur ThomX.

Problème avec le démarrage de Plateforme IHM qui ne s'ouvre pas, en cours de résolution

  152   Mon Nov 8 09:31:04 2021 Entered by sophie chance from 134.158.195.141 on Mon Nov 8 09:30:51 2021Under ProcessQuestionLinac Commissionning Modulateur 

Un panneau attention est affiché sur le modulateur, Mise en chauffe quand meme pour tests.

Le panneau attention disparait à la mise en chauffe

  153   Mon Nov 8 10:28:52 2021 Entered by sophie chance from 134.158.195.141 on Mon Nov 8 10:28:35 2021Under ProcessInfoLinac Commissionning Zone de stockage 

Le rondier de la zone de stockage est désactivé. C'est une zone à laquelle nous n'avons pas accès.

Une demande au SPR a été faite.

  155   Mon Nov 8 12:44:47 2021 Entered by sophie chance from 134.158.195.141 on Mon Nov 8 12:44:33 2021Under ProcessShift summaryLinac Commissionning transport faisceau 

Personnes : SC, CB,

visu du faisceau sur le premier écran. La visu est différente d'avant l'intervention sur la jauge (faisceau situé plus bas). En focalisant avec le solenoides, nous avons maintenant le faisceau photoemis et le courant d'obscurité. Les steerers sont à zéro, phase 24 degrés, atténateur canon 1 db, atténuateur section 1 dB, modulateur 1050kV. Imaage sauvée à 12h40. On passe la section. On le voit sans steerers. On a l'impression qu'il reste tout de meme un kick,mais Il faut recadrer la caméra pour voir tout l'écran.

Les wavecatchers ne fonctionnent pas. Il faut travailler l'alignement cette après midi.

Le modulateur est mis en HV pour une redémarrage rapide en début d'après midi.

On redémarrage dans l'après midi. Le faisceau est retrouvé après un petit réglage des phases.

Je passe la main à Nicolas pour les TP GI, et Emmanuel pour l'alignement laser+ solenos

 

 

 

  158   Tue Nov 9 09:12:28 2021 Entered by sophie chance from 134.158.195.141 on Tue Nov 9 09:12:14 2021Under ProcessInfoLinac Commissionning démarrage 

Démarrage modulateur, temps restant 3590 s environ

Acces casemate prévu pour Iryna et Slava avant faisceau

  160   Tue Nov 9 18:30:37 2021 Entered by Hayg Guler from 134.158.195.141 on Tue Nov 9 18:30:22 2021Under ProcessShift summaryLinac Commissionning Resumé du jour icon1.gif 

Shift consacré à la calibration des moniteurs de pertes ainsi qu'à l'allignement de la tete de machine (Laser + Solénoide)

  •  Solénoide :

    • cables de l'encodeur des moteurs LI/AE/COL.01(02)-MOT.01 étaient intervertis, sont maintenant bien rebranchés

    • Demain : il faudra vérifer le mouvements correspondant aux pas moteur 

  • BLM : 
    • Signal BLM étudié sur scope 
    • Signaux montrant les positions de l'entrée de la section et du 1er yag (A confirmer demain
  165   Tue Nov 16 11:44:06 2021 Entered by Hayg Guler from 134.158.195.141 on Tue Nov 16 11:43:53 2021Under ProcessInfoLinac Commissionning Shift Alignement tete de machine  

Laser : 

  • Nouveaux hublots pour le Laser photocathode 
  • Environ 50 µJ sur la photocathode
  • Stabilité : 
    • mean x 5907.66 µm +/- 96.93 µm
    • mean y 3085.29 µm +/- 300.62 µm  (pas très stable)
    • FWHM x 1375.37 µm +/- 460.10 µm
    • FWHM y 1150.08 µm +/- 369.14 µm

Linac: 

  • On a démarré avec 2dB d'atténuation sur le Canon --> 69 MV/m
  • Charge max : 175 pC (voir figure)
  • 14h40 : pour la suite on se place à 0.75 dB d'atténuation (1090V ) donc 81 MV/m 

Moteurs Solénoide :

 

 

 

 

 

 

Attachment 1: charge_pahse.jpg
charge_pahse.jpg
  167   Wed Nov 17 11:28:50 2021 Entered by Super Team from 134.158.195.142 on Wed Nov 17 11:28:36 2021Under ProcessInfoLinac Commissionning run du 17 novembre 

pour rappel le programme de la journée :

•Vérification de la charge et de l'énergie en fin de linac pour les tests du 27 (en cours),

•prévoir le passage à 1090 sur le modulateur (présence de Mohamed pour le réglage section)-->fait, atténuation de 1.5dB sur la section avec une tension de 1090 au modulateur

•IHM Charge fonctionnelle (mercredi, Nicolas)

•mise au propre énergie charge,

 

début du réglage :

atténuation canon : 0.75 dB (soit 5% de perte), atténuation section (2% de perte) 1.5 dB

charge phase, identification du max de charge à 306 degrés

Variation de la phase autour de cette valeur--> le faisceau reste en position, avec un tout petit décalage en vertical

- 50 degrés par rapport à la charge max : soit 256 degrés

- on alume les solénoides : le faisceau ne bouge pas avec le champ, position des moteurs : 0.912 mm (col01-mot01), 0.422 mm (col01-mot02), -0.161 mm (col02-mot01), 0.324 mm (col02-mot02)

- on compare avec les positions moteurs toutes nulles,  à dans ce cas, le faisceau bouge, on revient donc aux valeurs de la ligne précédente

 -focalisation sur l'écran à 204A sur col2, et 59 A sur col1 (0.289*col2) --> image enregistrée (ci jointe dans commissioning tool mesure 20211117 à 12h08)

- on passe la section sans steerer sur la partie li, le faisceau est visualisé sur l'écran LI/sst1, on baisse col2 à 180 A, le faisceau bouge avec le déphaseur section en vertical, mais reste dans l'écran toujours sans steerer

- mesure de charge en bout de section --> pas possible

- Mesure de la stabilité du laser : 78 um en x, et 99 en y, taille FWHM : 1441 +/-184 um en x, et 1190 +/- 39 um

- l'optimum de la phase de la section se situe à 3600 pas, 

- gradient canon 81 Mv/m, 5.3MW

-mise au propre énergie charge,.

 

Remarques :

- la caméra LI/SST saute une image de temps en temp, l'image sature m^eme en variant le max scale, gain à 1 db, on le met à zero, ca ne suffit pas, ca sature encore (temps d'expo 0•mise au propre énergie charge,- interface alim,0.01s

- ne met plus à jour le col 2 (11h53), relance de l'ihm hors plateforme pour test

- le timing du wavecatcher sortie section n'est pas bon

 

 

 

Attachment 1: charge_pahse.jpg
charge_pahse.jpg
Attachment 2: charge_phase.csv
,phaseRF,mean_ICT_LI_Q,std_ICT_LI_Q
0,180.0,-10.964252281188966,2.000563461947993
1,185.0,-10.451055240631103,1.5410995866590864
2,190.0,-10.501575660705566,1.4581943482617197
3,195.0,-9.87581377029419,1.8702255432918715
4,200.0,-10.634872531890869,2.0016064576777666
5,205.0,-10.148173427581787,2.8152546584342506
6,210.0,-10.570510005950927,2.154336534180102
7,215.0,-28.21781692504883,3.338873381352125
8,220.0,-53.6248275756836,9.39379471433439
9,225.0,-67.34863052368163,4.679300061131702
10,230.0,-75.39936981201171,2.6697636224237846
11,235.0,-80.53481979370117,4.919195250881207
12,240.0,-89.55007858276367,5.711220655032081
13,245.0,-89.26970596313477,3.793167520019974
14,250.0,-97.56754150390626,3.565336090596153
15,255.0,-95.1892303466797,5.275813037764538
16,260.0,-102.5515121459961,8.09504926852596
17,265.0,-112.2614616394043,2.4790731909584083
18,270.0,-111.85198440551758,5.610964484782218
19,275.0,-110.21761703491211,4.9218129430361754
20,280.0,-117.81357192993164,4.763549682562357
21,285.0,-117.04469528198243,9.991973308634117
22,290.0,-118.1262939453125,7.180655815372073
23,295.0,-118.73198547363282,7.87578433019698
24,300.0,-120.40200347900391,7.723829414063301
25,305.0,-116.06881256103516,8.513318513227084
26,310.0,-74.32159957885742,3.084158086000992
27,315.0,-23.32515983581543,1.891200327643989
28,320.0,-31.283192443847657,3.3003201452387856
29,325.0,-46.006564712524415,5.422746836578569
30,330.0,-12.006317234039306,1.7720209549614583
31,335.0,-10.431936597824096,2.4564645686855635
32,340.0,-10.08945255279541,2.440911870059966
33,345.0,-10.08882417678833,2.6016282919447726
34,350.0,-9.777323150634766,1.8162788230421527
35,355.0,-11.403638076782226,1.7829519322661747
36,360.0,-10.629283809661866,2.4642998691231113
Attachment 3: 2021-11-17_12_04_19_li_dg_sst_01-ccd_01_RAW.png
2021-11-17_12_04_19_li_dg_sst_01-ccd_01_RAW.png
Attachment 4: laser_13h.png
laser_13h.png
  170   Thu Nov 18 11:50:09 2021 Entered by Super Team from 134.158.195.141 on Thu Nov 18 11:49:51 2021Under ProcessLinacLaser | Linac Commissionning Charge avec ou sans l'Iris sur le laser icon1.gif 

Nous avons testé de retirer l'iris pour mesurer la charge.

la charge max passe de 100 pC max à 150 pC. Le bruit semble aussi plus important (plus de dispersion sur la charge).

 

Attachment 1: Laser_noIris.png
Laser_noIris.png
Attachment 2: charge_pahse.jpg
charge_pahse.jpg
Attachment 3: charge_pahse_noiris.jpg
charge_pahse_noiris.jpg
  171   Thu Nov 18 18:39:18 2021 Entered by Hayg Guler from 134.158.195.141 on Thu Nov 18 18:39:04 2021Under ProcessShift summaryLinac Commissionning Energies avant section pour différents gradients  

Methode : 

on utilise le steerer LI/PS/STR01-V01 et les mesures sont faites sur le Yag de la station avant la section. On soustrait le courant d'obscurité à chaque mesure pour avoir une mesure propre. 

A chaque valeur de gradient on remesure la position du maximum de charge (puis d'énergie) qui dépend du gradient. 

Atténuation Canon 0.75   E: 4.22 MeV
Atténuation Canon 0.25   E: 4.55 MeV
Atténuation Canon  0.     E: 5.06 MeV

  173   Mon Nov 22 11:21:00 2021 Entered by Super Team from 134.158.195.142 on Mon Nov 22 11:20:47 2021Under ProcessShift summaryLinac Commissionning run du 22 novembre 

Planning de la journée:

- Mesure d'énergie (Hayg, Christelle, Muath)

- Cyclage dipole (Jean -Noel, Iryna)

Déroulement :

Démmarrage modulateur, Interlock modulateur

Comparaison charge phase avec les deux méthodes de mesure

Vérification alignement laser en faisceau --> OK avec les positions données par Emmanuel

Vérification avec le solenoides --> encore un peu d'effort d'alignement à faire, m^eme si cela ne bouge pas beaucoup

Focalisation maximale sur l'écarn autour de 202 A/58A : prise de l'image faisceau laser on (11h49) et laser off (11h48)

mesure de la stabilité du laser : 

mean x 6177.74 µm    +/- 85.40 µm
mean y 3260.12 µm    +/- 115.34 µm
FWHM x 1924.36 µm    +/- 217.27 µm
FWHM y 1242.88 µm    +/- 132.42 µm

Phase à 247 degrés --> mesure d'énergie (Str01-H01=0.5A), on fait varier str01-v01 de -1 à +2A

Création d'un dossier canon, dans data/shared/comm8tools/mesure/canon/LI_SST1/scansteererV01

conditions : 1090VHT modulateur, atténuateur canon 0.5dB

srcipt scan_energie_image_canon dans commissioning script/linac

Phase = 247, b3=201A, Ekin = 4.2 MeV --> sauvé dans canonSST/energy_247deg_gun 0.5dB

Phase = 237; B3=203A, Ekin = 4.2 MeV  MeV

Pause déjeuner

planning aprem : Mesure énergie canon en baissant l'atténuation, puis mesure section

attenuation canon à 0.25dB, solenoide à 203A --> Ekin=4.38 MeV

On se met en HV pour pouvoir effectuer le cyclage du dipole --> amélioration en cours

 atténuation 0 dB, solenoide à 215A --> mesure 4.7-4.9 MeV mais avec quelques claquages

On passe la section avec une atténuation de 1.5dB soléno 180A, on bouge le déphaseur, le faisceau ne bouge pas sur l'écran avec le déphaseur, mais il a décalage en horizontale de (x=15.8, y 18) sans steerers

On se fixe à une phase de 100 deg sur la section (2401 moteur) --> image prise à 18h16 dans LIL. et avec la soustraction du dark current à 18h17

On trouve 57 MeV, mais attention l'écarn est en oblique et on prend la projection. On maximise donc l'énergie. Il faut corriger les distances, dans ce cas, on a 3 MeV de moins, mais toujours dans les 58-60 MeV

Si on augmente le nombre d'image par valeur de champ de steerer, on retrouve entre 50 et 60. On a des claquages --> a refaire avec les BPM et avec plus de stabilité

La suite demain !

 

  174   Tue Nov 23 10:44:04 2021 Entered by Super Team from 134.158.195.142 on Tue Nov 23 10:43:41 2021Under ProcessShift summaryLinac Commissionning run 23 nov 2021 

Intervention modulateur par Maher

Remise en eau dans la boucle générale par Jean-Noel

Constatation d'eau devant salle laser (fuite ?)

0 db canon

phase charge max 268 , phase energie max 218

Charge IHM charge et methode "non officielle" identique (50 pC)

Laser PC : 47 uJ sans Iris, 63 uJ en sortie de la ligne de transport

Viktor retire le hublot

Miroir 4 --> 5407.317 (y)  7.542 (x)

Apres alignement 5401 (Y) 0.542 (X)

Coil 210A 60A

IHM charge 170 pC

Passage section  --> charge ICT 150 pC

Pause dejeuner

Mesure du champ residuel des quad : 10 gauss

Solenoide 180A - charge sortie canon 220 pC qvec IHM - 238 pC methode non officielle

Charge sortie LINAC 230 pC - 190 pC non off

1.5 dB sur section 0 dB sur canon --> Energie 59 MeV (mesure ecran)

2 dB section --> 55-58 MeV 

 

On essaie de mettre le champ des 3 quad a zero

Quad 2 : 0 A --> 5 Gauss  / -0.08 A --> < 1 Gauss

Quad 3 : 0 A --> 20 G  / -0.03 G --> < 1 G

Quad 1 : 0 A --> < 1 a 2 G

Nouvelle mesure de l'energie a 2dB --> 54-58 MeV

Intervention fermeture iris laser 76 uJ, ouverture d'iris 3.5 (indication visuelle sur l'iris), 160 uJ à la sortie de la ligne de transport, 200 uJ à la sortie laser

Installation power metre de crete 9 MW à 2 dB d'atténuation

Suite --> demain

 

 

 

 

 

  177   Tue Nov 23 13:12:37 2021 Entered by Iryna Chaikovska from 134.158.89.93 on Tue Nov 23 13:12:22 2021Under ProcessOtherAimants | Linac Commissionning Cyclage quadrupoles 

23/11/2021

We would like to cycle the quadrupoles in the linac. The procedure of the cycling was provided by Cynhia (attached). 

The magnet current should be ramped from 0 to IMAX , decreased down 0 and ramped back to IMAX three more times. Measurement current will be finally reached going to nominal current ISet. (IMAX  = 12 A).  

Total cycling time is ~8 min [so ~1 min for 0 to IMAX, and the same for IMAX to 0). Waiting time at IMAX & I=0 is ~10 sec.

More probably this procedure is driven by the fact that the B(I) curves were provided for the positve values of I only I = 0..+12


As it was discussed with Cynthia: In order to set the negative current (defocusing quadrupole magnets), the  cycling procedure should be reversed. 

When the calibration curves [-12 A +12 A] will be available, the procedure has to be the following. The magnet current should be ramped from 0 to IMAX , decreased down to -IMAX and then ramped again up to IMAX. 

Measurement current will be finally reached going to nominal current ISet. (IMAX  = 12 A).  Total cycling time is ~6 min [so ~1 min for 0 to IMAX, and the same for IMAX to - IMAX). Waiting time at IMAX & I=0 is ~10 sec.

Figure attached: Quadrupole cycling layout given by Cynthia.

Figure attached: Quadrupole cycling layout in case of bipolar power supplies and corresponding calibration curves.

For the linac, to set the quadrupoles to 0, we can use the last procedure involving the + I max and -Imax (figures attached) and for later, we should discuss with Fabrice Marteau how we procceed. 

We made the cycling for the QUAD qnd still we have 5-10 G of the remaining field. To be understood....

 

Attachment 1: Screenshot_2021-11-23_at_13.14.26.png
Screenshot_2021-11-23_at_13.14.26.png
Attachment 2: Screenshot_from_2021-11-23_14-09-27.png
Screenshot_from_2021-11-23_14-09-27.png
Attachment 3: Screenshot_from_2021-11-23_14-10-15.png
Screenshot_from_2021-11-23_14-10-15.png
Attachment 4: cylage_quad.png
cylage_quad.png
Attachment 5: cylage_quad2A.png
cylage_quad2A.png
  178   Wed Nov 24 11:21:41 2021 Entered by Super Team from 134.158.195.141 on Wed Nov 24 11:21:24 2021Under ProcessLinacLaser | Linac Commissionning shift du 24 Novembre 2021 

Laser :

  • Viktor a remis le hublot pour gagner en stabilité laser
  • Energie laser : 54 µJ
  • laser beaucoup plus stable :
    • mean x 5253.12 µm +/- 43.89 µm
    • mean y 2941.86 µm +/- 70.49 µm
    • FWHM x 1690.52 µm +/- 170.79 µm
    • FWHM y 1367.08 µm +/- 36.47 µm

Charge :

- Scan nous donne une charge max à 263°
- Solénoides : 225 A pour avoir l'image sur SST01 du Linac.
- Image en PJ : saturation observée à charge max sur le Yag LI_SST01
- Solénoide à 195 (250 sur Atténuateur laser pour ne pas saturer le Yag) pour avoir un spot très petit sur le Yag : taille x= 0.36, y = 0.8 mm

 

 

 

Attachment 1: charge_phase__at_24-11-2021__15-11-41.jpg
charge_phase__at_24-11-2021__15-11-41.jpg
Attachment 2: Screenshot_from_2021-11-24_15-23-50.png
Screenshot_from_2021-11-24_15-23-50.png
Attachment 3: Screenshot_from_2021-11-24_15-51-42.png
Screenshot_from_2021-11-24_15-51-42.png
  179   Wed Nov 24 16:52:29 2021 Entered by Super Team from 134.158.195.141 on Wed Nov 24 16:52:10 2021Under ProcessLinacLinac Commissionning Mesure d'energie 