Entered by Super Team from 134.158.195.141 on Thu Dec 16 09:53:20 2021; Demarage machine
|
Les chillers sont démarrés et le modulateur en chauffe
Test de l'influence sur les erreurs de synchro |
Entered by Super Team from 134.158.195.141 on Tue Apr 29 11:02:38 2025; Data taking for ML
|
Demarrage ACQ pour ML
Random : Phi_GUN, Phi_Section, ST1, ST2, Solenoid, QP1, QP2, QP3
Mesures : BPM1, BPM2, Charge, Laser, YagTL, Intensité Ecran |
ND, Anna K, Elene K; Data taking 26/01 7x
|
9:30 Warm-up
11:00 Modulator OFF => restart warm-up
Pb temperature section. |
Entered by Super Team from 134.158.195.141 on Mon May 19 17:56:57 2025; Data : Sole scan, Q scan, random linac Yag_TL1
|
Today's data :
- coil scan (+ images)
- Q3 scan |
Entered by Super Team from 134.158.195.143 on Wed Sep 29 16:57:52 2021; Dark current
|
Pemiere image du courant d'obscurité.
L'image est prise sur la station SST01 du Linac. |
Hayg; DS pour les températures des chillers
|
Listes des Ds pour les températures des chillers
GUN : ER/HF/RAC.17-API.AI1/AI2
Section : ER/HF/RAC.17-API.AI1/AI1
Emplacements :
Sortie Chiller : |
Entered by Super Team from 134.158.195.141 on Wed Oct 27 16:48:32 2021; DS calc en défaut
|
Les DS CALC sont en défaut et impossible de les relancer sur client3. Ils n'apparaissement pas dans astor.
Quelqu'un peut il résoudre le problème ?
|
Entered by Nicolas Delerue from 134.158.195.144 on Thu Jan 9 10:30:34 2025; DS ThomX_PhotoCathode using a lot of CPU 
|
The load on client5 is 29 making all operations slow.
Appently the DS ThomX_PhotoCathode is using a lot of CPU, slowing the rest.
|
Entered by Iryna Chaikovska from 134.158.89.93 on Tue Nov 23 13:12:22 2021; Cyclage quadrupoles    
|
23/11/2021
We would like to cycle the quadrupoles in the linac. The procedure of the cycling was provided by Cynhia (attached).
The magnet current should be ramped from 0 to IMAX , decreased down 0 and ramped back to IMAX three more times. Measurement current |
Entered by Iryna Chaikovska from 134.158.195.143 on Tue Nov 23 10:56:34 2021; Cyclage dipole  
|
For 22/11/2021
There is the remaining field from the dipoles in the TL. In order to go straight to the dump, the idea was to cycle the dipole to have 0 field.
We have tried the cyclage given by the ALBA peopel/Cynthia. Total time ~ 17 min. After two cycling, the remaining filed alwayd stays at ~20 G. |
Entered by Iryna Chaikovska from 134.158.195.144 on Mon Mar 21 09:52:37 2022; Cyclage QUAD (TL)
|
The cycling of the following quads ( to zero current) were tested. The corresponding cycling cuves were loaded in the DS (checked).
TL/PS/cycleQP.01
TL/PS/cycleQP.02 |
Emmanuel Goutierre; Conversion valeur moteur rotation solénoïde
|
Conversion des valeurs des moteurs de rotation du solénoïde
axmo_z
Diamètre de rotation : 552mm |
Entered by Super Team from 134.158.195.142 on Thu Nov 25 17:07:16 2021; Contrôle terminé
|
| |
Entered by Super Team from 134.158.195.142 on Thu Nov 25 15:01:41 2021; Contrôle Radioprotection
|
Les controles radioprotection ont commencé vers 14h50
Paramètres faisceau : 100 - 110 pC de charge, E=50 MeV et 10 Hz |
M.O, M ELK, Hayg, Slava; Conditionnement section SC/ME/MO/VK/HG
|
signaux RF mesurés :
avec Oscillo :
orange : reflechi section Prs |
M EK, SC, ND, VC; Conditionnement section 6/06 
|
8h20 : mise en chauffe de modulateur
start frigo et chiller section
Pression SF6 2.6 bar |
M.O, M ELK, Slava , Iryna; Conditionnement section 31/07 
|
signaux RF mesurés :
avec Oscillo :
orange : reflechi section Prs |
MEK, ND, VC, ; Conditionnement section 30/05 
|
08h30: set to stanby modulator
start frigo & chiller section
start cond. @ 2 dB ( Pis= 16 MW) @ 2µs & 5 Hz. |
M ELK, Slava, Iryna, Hayg; Conditionnement section 29/07 
|
signaux RF mesurés :
avec Oscillo :
orange : reflechi section Prs |
M EK, KD, DN, HG; Conditionnement section 29/05
|
8h45: set to standby Modulateur
start Frigo et chiller section
start cond. @ 1.4 dB ( Pis=18 MW) @1µs & 5Hz vide <1.3 e-8 mbar |