692
|
Tue Feb 21 12:41:58 2023 |
ND, VK, VM, MJ | Under Process | Shift summary | LI |
|
Shift 21/2 | |
12:20 Mise en chauffe modulateur
13:44 Scan charge phase OK
Note: TL-V2 est fermee...
13:58 Chargement recette good_20230217_13_09_42
Pb vanne resolu
14:08 Temperature chiller elevee!
Chargement des valeurs de https://elog.lal.in2p3.fr/THOMX/Commissionning/687
Reglage de la machine par Marie
Scan emittance
Recette aligement dans les quads du linac sauvee dans Li+TL: good_20230221_15_37_29
17:58 Arret machine
Update: Emittance measurements postprocessing made by Victor are in the attached powerpoint document. Preliminary conclusion: bad emittance could be due to some problems in the photoinjector gun. |
|
Draft
|
Fri Mar 3 11:49:50 2023 |
VK VM | Not Fixed | Shift summary | LI | Ring | Linac Commissionning | Ring Commissioning |
|
Shift 03 | |
Start modulator; alims;
We cannot start machine. No e-beam. Timing laser RF? Need help of linac team.
Kevin solved problem with shutter.
Check alignment at QP3.
Check phase of the section, go to 1.35 dB.
Libera4 reboot.
Measure orbit.
Try to change frequency of synthe from 500 to 500.43 resulted in the change beam position in TL BPM2, but it should not do anythyng with TL. Same shift is observed at the screen in the same position.
Vincent tryies to understand how to interpret this behaviour.
|
|
1134
|
Thu Oct 9 08:37:45 2025 |
Entered by Super Team from 134.158.195.141 on Thu Oct 9 08:37:29 2025 | Under Process | Shift summary | LI | TL | LE | Ring | Diag | Aimants | CC | Infra | Laser | Opt | RF D1 | RF Anneau | MECA | SY | Vide | Electronique | Linac Commissionning |
|
Shift "du Jeudi" : VM/HG/KD/DN/RC | |
09h35 Warmup ThomX
09h40 Cycling all magnets
09h50 Start Chillers
09h48 HV is ON
The reflected wave from the RF gun seems too high. Trying to set it to 27°C, but the clarinet temperature rises to 30.4°C and does not change.
10h15 HV is OFF
10h27 Stop the Gun chiller.
10h50 Start the RF Gun chiller. The temperature is constantly rising.
11h25 Kevin reloaded the RF gun chiller. All is OK
17h00 Beam is in the ring. Receipt was loaded from 10/04/2025 17:32, RCDS, Good storage, Orbit adjustment to measure bunch length with MRSV. There is the light on the camera. Receipt saved 09102025 17:07
Emittance measurements during the shift as well, at QP1, QP2 QP3 with low charge 70pC(0.8 mm) normal charge 100pC(1.3mm) and (300pC)3mm : here we wanted to see the affect of asymetric laser beam as well.
QP4-Scan also but scan is strange (and long ... 1s expo to see something)
|
|
218
|
Tue Dec 14 13:52:35 2021 |
Entered by Moutardier Alexandre from 134.158.195.142 on Tue Dec 14 13:52:18 2021 | Under Process | Shift summary | Linac Commissionning |
|
Shift après-midi | |
Opérateur : Hayg, Vincent, Nicolas, Alexandre M.
But de la journée :
- Correction des erreurs restante ci-dessous/Démarrer la machine
- Tester les modifications de l'interface sychro
- Ajouter d'un nouvel état health check
- Modification soft frequence Synchro
- Test tir unique en faisceau
14h : État de la machine en arrivant :
- Porte de la salle de controle maintenu ouverte sans opérateur et le compte opérateur en état d'opération...
- Heath check : voir health_check_14-12-21.png
- Alimentation : Pas de soucis, juste en état OFF
- Laser :
Moteur miroir li/op/opt.01-mir.04-mot.02 : OFF (Rallumé, problème réglé),
DS li/op/opt.02-las.01-osl.01 : Fault -> discussion avec les Viktor mais ce DS semble inutilisé -> DS initilisé ! Modification de Health_check
- Vide :
Vanne : Fault -> Valve MOVING, Valve IN FAULT, Valve FAULT MEMORIZED, Incoming security disabled, Valve in local mode -> a voir avec les vidiste
Revenu en état OPEN près quelque temps, un FaultAck sur l'ATKPannel à permit de revenur a un état normal -> problème reglé
- RF :
DS CALC (calc/er_hf/rac.17-api.ai1_ai1, calc/er_hf/rac.17-api.ai1_ai2, calc/er_hf/rac.17-api.a01_ao0, calc/er_hf/rac.17-api.a01_ao1) éteint -> Une fois démarré, problème réglé
- Diag :
DS CALC (CALC/ICT/Charge_LI-ICT.01_WAC.01-Ch0, ...) Fault -> Besoin de démarrer MeanStd
Un nouvel état "OFF" dans health_check vas etre testé pour évité une erreur dans le cas d'un DS éteint ne génant pas le démarrage de la machine.
15h30 :
Modification frequence synchro. Modifications verifié, IHM à mettre à jours.
15h40 :
La machine a été décalé de + 50 µs.
17h :
Modification Health_check testé et poussé
Modification IHM retard
17h30:
Ronde de la fosse sud/nord, casemate, Modulateur
Démarrage Modulateur -> Interlock -> reset + trig -> RF revenue
Scan charge-phase rapide : scan_charge_phase-14-12-21.png
-> phase charge max : 158°
(Le e-log ayant planté, dans la suite les horraires sont aproximatifs...)
18h : Le modulateur c'est éteint (mode OFF) sans raison apparente. Aucun interlock, aucune alarme, rien.
On a continuer a travailler sur les interfaces mais on a décidé de ne pas rallumer le modulateur à cause de la chauffe.
Bilan :
- Correction des erreurs restante ci-dessous/Démarrer la machine
-> l'accélérateur a fonctionné pendant quelques heures
- Tester les modifications de l'interface sychro
-> Tout fonctionne
- Ajouter d'un nouvel état health check
-> Tout fonctionne
- Modification soft frequence Synchro
-> Tout fonctionne
- Test tir unique en faisceau
-> Verrification de l'envoie des signaux de synchro en mode tire unique. Test avec faisceau a faire un autre jour.
|
|
591
|
Fri Oct 14 12:59:34 2022 |
Entered by Marie Jacquet from 134.158.205.43 on Fri Oct 14 12:59:10 2022 | | Info | Linac Commissionning |
|
Schema position elements LINAC | |
Demande par plusieurs personnes, je vous transmets ici mon schema de la position des elements dans le LINAC |
|
95
|
Thu Oct 7 17:12:58 2021 |
Entered by Hayg Guler from 134.158.195.141 on Thu Oct 7 17:12:27 2021 | Fixed | Linac | Linac Commissionning |
|
Scan charge phase | |
Scan charge phase : ajustement avec les deux déphaseurs, phase shift du laser à 82 ps.
Il faut bien penser à cliquer sur enable phase shift à chaque modification.
Scan effectué à partir de l'intégrale des signaux bruts.
|
|
157
|
Mon Nov 8 18:01:06 2021 |
Entered by Moutardier Alexandre from 134.158.195.144 on Mon Nov 8 18:00:52 2021 | | Info | Diag | Linac Commissionning |
|
Scan charge phase | |
Scan charge ICT linac phase canon fait le 08 Nov 2021
Scan tous les degrés, 10 mesure de charges pars point de 150 à 360 degrés.
(script : $HOME_IHM//mesure_charge_from_raw.py
commande : ipython mesure_charge_from_raw.py 150 360 1 10 li) |
|
199
|
Fri Dec 3 19:07:10 2021 |
Entered by Super Team from 134.158.195.141 on Fri Dec 3 19:06:53 2021 | Not Fixed | Info | Linac Commissionning |
|
Saut de phase |
|
Run pour travailller sur les alignements:
- Phase de max de charge : 125°
Saut de phase sur la phase laser : voir le plot de BPM qui passe à zero quand on "perd" le faisceau du à un saut de phase.
La phase a shifté d'environs 60°
- nouvelle phase de max de charge : 185° (elle semble bouger à nouveau)
- nouvelle phase de max de charge : 195° (elle a bougé à nouveau ...)
- nouvelle phase de max de charge : 202° ... 207° ..(elle a bougé à nouveau ...)
Nous avons fait des scans sur les moteurs des solénoides.
données disponibles sur --> /data/shared/Commissioning_tools/Mesure/20211203/
nous avons réussi à diminuer l'amplitude du déplacement du centroide du faisceau en fonction du champ du solénoide.
Il faut maintenant alligner plus finement en vérifiant bien les limites des moteurs. A voir lundi.
21h10 : on arrete
|
|
958
|
Tue Nov 12 10:36:39 2024 |
Entered by Viktor Soskov from 134.158.195.153 on Tue Nov 12 10:36:24 2024 | Fixed | Info | Laser |
|
Salle laser ThomX | |
Bonjour , l'intervention du Dalkia sur le CTA de la salle laser est terminee.
Viktor. |
|
1192
|
Fri Feb 13 17:38:15 2026 |
Entered by Super Team from 127.0.0.1 on Fri Feb 13 17:38:00 2026 | Under Process | Shift summary | LI |
|
SHift du jour | |
The code for laser alignment does not work properly --> done by hand
H 5.244
V 4.654
phiMax section = 224
position change (yag screen in pixels) vs delta phase
| phi |
posH |
posV |
| 224 |
350 |
267 |
| 254 |
340 |
272 |
| 264 |
335 |
260 |
| 204 |
340 |
266 |
| 184 |
274 |
280 |
Sole 230:
Eps X:
emit_norm : 1.3682 mm.mrad
beta : 19.51 m
alpha : -6.673
Eps Y:
emit_norm : 1.7366 mm.mrad
beta : 10.60 m
alpha : -3.606
Scan_QP0118h01.mat : 230
Scan_QP0118h09.mat : 240
Scan_QP0118h22.mat : 235
Scan_QP0118h26.mat : 225
Scan_QP0118h31.mat : 235 :
Scan_QP0118h31.mat : 235 : gain 0
Scan_QP0118h36.mat : 240 : Gain 0
18:40 stop |
|
37
|
Tue Jun 15 15:44:40 2021 |
Entered by Sophie Chance from 134.158.195.141 on Tue Jun 15 15:44:19 2021 | Under Process | Linac | RF D1 |
|
SF6 | |
Pompage SF6 en cours
Fin des tests PSS prévu pour 17h
Pompage SF6 terminé 16h00 |
|
24
|
Tue Jun 8 17:40:20 2021 |
Entered by Sophie Chance from 134.158.195.144 on Tue Jun 8 17:40:07 2021 | Fixed | Shift summary | resumes |
|
Résumé de la journée | |
- Pour les atténuateurs : les butées ont été trouvées, ATT02-MOT01 c'est la canon, ATT01-MOT01 c'est la section.
- Des difficultés ont été rencontrés avec le modulateur : Interlock à cause de l'eau, interlock alim HT, reboot modulateur et vérification de l'autorisation de tir MPS faite.
Le modulateur fonctionne maintenant sans problèmes à une tension de 1240V et un vide klystron de 1.2 uA qui devrait diminuer par la suite. Les mesures radioprotection ont été faites
- Pour le MPS, cliquez sur Paramètres en bas de l'écran principal puis vérifier que LINAC est on.
Pour demain :
- Démarrer régulation eau en plus du modulateur
- Vérifier les signaux RFs sur oscillo et Réglage des retards (demarrage_delays)
- Ne pas mettre beaucoup de puissance, vérifier la chaine RF et vérifier les atténuateurs
- Vérifier caméra et ICT |
|
329
|
Fri Feb 11 16:06:56 2022 |
Entered by SC/HM from 134.158.195.142 on Fri Feb 11 16:06:32 2022 | Under Process | Shift summary | Linac Commissionning |
|
Résumé | |
- L'énergie du laser mesurée à 60 uJ après alignement sur la table optique. Faisceau laser non visible sur la camera qu'on ne peut pas passer en trigger externe.
- Problèmes avec les Icepap réglés pour les moteurs du laser
- Le modulateur fonctionne, à valider avec la valeur de travail 1000 ou 1090V
- Impossible de voir les signaux RFs sur l'interface avec les redpitayas (malgré un re-démarrage)
- Problèmes de réglage de la synchro : DS qui ne redémarre pas, le chargement de recette a chargé les valeurs mais ne les a pas validées. La mise à jour faite ensuite pour valider les valeurs a affiché des valeurs non voulues.
- Le DS laser ne fonctionne pas, le ping laser amplitude fonctionne |
|
84
|
Fri Oct 1 16:42:41 2021 |
Entered by Alexandre Moutardier from 134.158.195.144 on Fri Oct 1 16:42:28 2021 | | Info | SY |
|
Réglage timing RF/Laser | |
Le timing du laser et de la RF sont réglés.
Une recette (20211001_1631-sync_premier_faisceau.xml) a était sauvé. |
|
32
|
Thu Jun 10 14:00:05 2021 |
Entered by bruni from 134.158.195.141 on Thu Jun 10 13:59:50 2021 | Fixed | Info | etc |
|
Réglage des retards | |
|
|
206
|
Fri Dec 10 17:21:29 2021 |
Entered by Super Team from 134.158.195.141 on Fri Dec 10 17:21:13 2021 | Under Process | Linac | Laser |
|
Réalignement du Laser | |
Laser :
Viktor a joué sur le transport du laser. La distribution s'est nettement améliorée car on ne doit plus passer par la zone endomagée du hublot.
voir les images sans et avec l'iris.
pas de mesure d'énergie pour le moment. On va essayer de tourner un peu avec ce faisceau.
Mesure stabilité de pointé :
mean x 5998.93 µm +/- 92.98 µm
mean y 3100.70 µm +/- 137.65 µm
FWHM x 1954.20 µm +/- 72.28 µm
FWHM y 1421.95 µm +/- 112.86 µm
encore élevé ...
a 18h :
mean x 5978.89 µm +/- 64.64 µm
mean y 3107.10 µm +/- 107.76 µm
FWHM x 1950.55 µm +/- 148.38 µm
FWHM y 1421.62 µm +/- 109.17 µm
Charge :
La charge max passe de 20 pC à 120 pC. |
|
1015
|
Wed Feb 19 17:32:30 2025 |
shift screw | | Shift summary | LI | TL | LE | Ring | Diag | Aimants | CC | Infra | Laser | Opt | RF D1 | RF Anneau | MECA | SY | Vide | Electronique | Linac Commissionning | Ring Commissioning |
|
Rustine pour le probleme CEM kicker - ring storage - Xrays | |
Cable ventilo kicker debranche ==> aucun effet
Cable balise blinde ==> la balise redevient calme
Redemarrage
Stockage dans l'anneau (recette je ne sais pas laquelle) - Recherche synchro X ==> screenshot
* Fin de journee, pour la 3eme fois la communication avec l'ampli laser FPC fortement perturbee .....
* Probleme sur la voie 4 pico 3 (2diodes detector) ==> sceenshot |
|
347
|
Thu Feb 17 18:31:55 2022 |
Entered by Super Team from 134.158.195.141 on Thu Feb 17 18:31:40 2022 | Under Process | Linac | Linac Commissionning |
|
Run rapide : on reprend quelques points d'hier (HG) | |
Petit point à comprendre :
si on aligne bien le laser alors lorsqu'on fait varier la phase autour de la phase de charge max, le barycentre du faisceau ne doit pas changer. Or il semble que les données BPM et SST1 ne soient pas cohérents.
nous allons reprendre des données, BPM et SST1 ensemble pour s'en convaincre.
1) nous allons affiner l'allignement, il reste un petit facteur sur un des axes. Ici c'est l'axe Y.
18h50 : Modulateur OFF .... Tempo : 10-15 min au lieu d'1h ... c'est une amélioration mais faut comprendre pourquoi il est passé OFF
19h15 : Modulateur OFF ... Tempo : Passe de qq secondes à qq minutes ... pourquoi ça augmante ? rien a faire ça reste sur OFF ... J'arrete @19h25
Un peu désaligné en Y
On a rattrappé avec le moteur en Y
|
|
457
|
Wed May 11 18:32:38 2022 |
Entered by Super Team from 134.158.195.141 on Wed May 11 18:32:20 2022 | Under Process | Info | Linac Commissionning |
|
Run machine : JNC/HG | |
But du run :
refaire le transport jusqu'au DUMP en vérifiant le transport (steerers entrée section).
Laser :
pas centré dans l'iris

Apres correction sur M5:

Iris (li/op/opt.01-dia.01-mot.01) : Position : 2 mm
Stabilité Laser :
mean x 5136.50 µm +/- 9.84 µm
mean y 3521.23 µm +/- 20.95 µm
FWHM x 1129.35 µm +/- 8.70 µm
FWHM y 1151.89 µm +/- 12.77 µm
Position : 1.5 mm

Stabilité :
mean x 5154.80 µm +/- 6.80 µm
mean y 3532.75 µm +/- 12.97 µm
FWHM x 980.17 µm +/- 5.79 µm
FWHM y 1003.99 µm +/- 9.83 µm
Charge phase : plusieurs position du moteur d'atténuation ont été utilisés : 400 (Att min) 350 et 300 : /data/shared/Commissioning_tools/Mesure/20220511/Charge_phase
Phase de Charge max : 346-347° --> Charge max 40pC pour une Atténuation à 300.
Saut de phase (150° environ) entre hier et aujourd'hui suite certainement au redémarrage du laser.

Réglage alignement Solénoide :
Reprises de l'alignement TX0 TY 2.4 RX 6 RY -5
Att Laser 330 , Q 94pC
Scan phase LIL :
/tmp_mnt/data/shared/Commissioning_tools/Mesure/20220511/Scan_Data_Allign_LIL/
derniere valeur : LI_STR_1H-0.0_LI_STR_1V-0.0_LI_STR_2H-1.22__LI_STR_2V0.37

|
|
Draft
|
Thu Dec 2 14:54:52 2021 |
Entered by Super Team from 134.158.195.141 on Thu Dec 2 14:54:39 2021 | Under Process | Linac | Laser | Linac Commissionning |
|
Run Linac alignement | |
Laser:
Viktor est intervenu pour tourner le hublot afin d'améliorer la distribution du spot laser sur la photocathode. La stabilité reste très bonne.
Energie : on est revenu à 50 µJ
|