15
Wed Oct 31 13:43:28 2018
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Finesse vs power by difference between main and second resonance
Measurement on 24/10/18
16
Wed Oct 31 13:44:22 2018
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Finesse vs power by difference between main and second resonance
Measurement on 25/10/2018
17
Wed Oct 31 13:48:58 2018
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
M1 transmission measurement
Center of M1:
I
18
Wed Oct 31 13:51:17 2018
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Change of the 3 ULE mirrors by 3 spare ULE mirrors
First finesse measurement 20 266, FSR 133.351
MHz under vacuum
19
Wed Oct 31 14:03:22 2018
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
M4 transmission measurement
The kept transmission for M4 is
2.17 ppm. Which is the value
measured after alignement (center of the
20
Wed Oct 31 14:04:50 2018
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
M4 transmission measurement
Loïc
21
Wed Oct 31 14:06:17 2018
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
M1 transmission measurement
At different positions, transmission give
194, 193, 208, 200 ppm?
22
Mon Nov 5 13:11:08 2018
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
First run with spare mirrors
I (A)
23
Thu Nov 15 13:02:44 2018
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Mirrors cleaning
The new mirrors didn't give expected
results. Then the 4 old mirrors have been
sent to LMA on 12/11/18 for a cleaning and
24
Fri Dec 21 13:42:43 2018
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Mirrors features, come back from LMA
Mirrors arrived today from LMA. Their features
are damaged.
Photos avant ou après nettoyage,
25
Thu Jan 24 17:44:21 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Deposit on S-box mirrors after return from LMA
Cleaning on dirty surface shows something
is deposited on the surface. Cleaning displaces
and removes part of the deposit.
26
Thu Jan 24 17:49:54 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Impacts on mirror's surface
All the mirrors show impacts on there surface
(some of them do not show deposit). Does
it come from experiments or fabrication ?
27
Fri Feb 1 13:45:19 2019
Loïc Amoudry
Fixed
report
lasers and optics
Other
AFM performed on S-BOX mirrors
29/02/19 - AFM has shown that spots
on mirror's surfaces are bumps and not
holes.
28
Fri Feb 1 14:04:27 2019
Loïc Amoudry
Fixed
info
lasers and optics
Other
Meeting with LMA people, AFM
30/01/19 - The following powerpoint
shows the results discussed with LMA people.
What came out from the discussion
29
Wed Nov 13 13:15:53 2019
Loïc Amoudry
Fixed
report
lasers and optics
Other
AFM+ InfraRed spectroscopy (IR spectro) has been performed
AFM+ InfraRed spectroscopy (IR spectro)
has been performed on 400kW S-BOX mirrors.
Seems that XPS made M3 and M4 dirty,
30
Fri Dec 6 11:53:53 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Mirror's cleaning
XPS has been proceeded on the 400kW SBOX
mirrors M3 and M4 (the initial cavity spherical
mirrors) in frebruary 2019. Deposited a lot
31
Fri Dec 6 11:54:58 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Mirror's installed
The initial 400kW SBOX mirrors which have
been cleaned ont 28th of november have been
installed this morning on the SBOX.
46
Thu Jan 9 16:54:05 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Microscope and cleaning of SBOX mirrors
The mirrors went in the cavity the 28th
of november (We did several power up
to 30kW stored and only one to 40kW then
49
Fri Jan 24 17:52:14 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
AFM analysis of M1
AFM has been proceeded on M1 and M2.
The pdf shows the first images
taken with the PLIC room Leica microscope
50
Fri Jan 24 17:56:11 2020
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
AFM analysis of M2
We had enough time to proceed a quick scan
of M2 which has also a hole but not centered
on the mirror.