HOME SBOX THOMX MINICAV Utilities
SBOX orders SBOX installation SBOX commissioning SBOX control command
  Status of commissioning, report also here plots are reports.  Not logged in ELOG logo
Entry   M1 transmission measurement, posted by Loïc Amoudry at Optical room about lasers and optics 
    Reply   M1 transmission measurement, posted by Loïc Amoudry at Optical room about lasers and optics 
Message ID: 17     Entry time: Wed Oct 31 13:48:58 2018     Reply to this: 21
 Author: Loïc Amoudry 
 Status: Fixed 
 Type: report 
 Category: lasers and optics 
 Location: Optical room 
 Title: M1 transmission measurement 

Center of M1:

I (A) Input power (mW) Transmitted power (mW) Transmission (ppm)
0 78 0.01477 189
4 16500 3.2 194
ELOG V3.1.4-395e101