VC; frequency linac
|
| La frequence linac est passée à 2998.55MHz |
Entered by Vincent Chaumat from 134.158.76.115 on Tue Mar 19 16:24:21 2024; Synchro démontée
|
La synchro n'est plus en place à l'heure actuelle.
un générateur permet d'avoir des signaux en sortie du DEG1(modulateur) et du DEG4(Linac) (fréquence 10Hz)
|
Entered by Vincent Chaumat from 134.158.76.115 on Tue Mar 19 16:24:21 2024; RE: Synchro démontée
|
La synchro a été remise le 09/04/2024, le rapport et en P.J.
Entered
by Vincent Chaumat from 134.158.76.115 on Tue Mar 19 16:24:21 2024 wrote:
La synchro |
VC; Largeur impulsion Timing camera
|
Les largeurs des impulsions de synchronisation de toutes les caméras de ThomX sont passées à 10µs (last value 5µs)
Camera linac TL1 TL2 TL3 EL DG spare et laser PC |
Entered by Vincent Chaumat from 134.158.76.115 on Thu Jun 27 16:33:02 2024; Synchro
|
Les codes synchros présent dans l'IHM phase et fréquence sont opérationnel (ancien code max 10Hz)
|
VC, ND; Codes de synchro mis a jour (25Hz)
|
Les codes de synchro ont ete mis a jour et testes.
Il est maintannt possible de passer a 25Hz sur le linac et l'anneau. Les diags sont limites a 8,33Hz. |
VC, ND; Synthe linac
|
| Le synthe du linac a ete remis en place et teste a bas niveau. |
VC, ND; RE: Synthe linac
|
Attention si vous passez pres de la baie 8: certains cables n'aiment pas etre caresse. Si le voyant trigger ne clignote plus, appelez la synchro...
VC,
ND wrote:
Le synthe du linac a ete remis en place et teste a bas niveau. |
VC, ND; RE: Codes de synchro mis a jour (25Hz)
|
La limite sur les diags a levee. Ils peuvent passer a 25Hz aussi.
VC,
ND wrote:
Les codes de synchro ont ete mis a jour et testes. |
VC,ND; Decalage temps de declenchement machine.   
|
9:20 Le laser est a -8.20us
Verification du retard de la camera LI/OP/LAS.02 en decalant en temps le laser de 999us.
La camera se declenche bien environs 600us avant le laser. |
VC; procedure fréquence
|
dossier panneau\synchro (cdi)
./ring_frequency.py --help (voir le mode de fonctionnement)
./ring_frequency.py --freq "value" (choisi que des fréquences possible pour la div par 15) |
VC; MESURE STABILITÉ SYNCHRO
|
La synchronisation des signaux mesure suR le timing 50Hz
500MHz LI 500MHz RI => 18ps sdev
500MHz LI 50Hz => 190ps sdev |
Entered by Nicolas Delerue from 134.158.195.142 on Fri Dec 20 12:03:15 2024; Added a "diags only" button on Rep rate GUI  
|
Two buttons have been added to the repetition rate interface (see attached screen shot):
- "diags only": Will inhibit all channels from the ring and linac delay generators
- "restore linac and ring": Will set all channels of the ring and linac delay generators to External triggering. |
Entered by Nicolas Delerue from 134.158.195.144 on Thu Jan 9 14:12:31 2025; DS to monitor missed triggers
|
A ds to monitor missed triggers has been added in CALC/SY/missed_triggers
|
Entered by Super Team from 134.158.195.141 on Wed Feb 19 10:59:02 2025; Carte synchro
|
Changement de carte synchro
le MCT2 de la carte en place à bruler
|
Entered by Vincent Chaumat from 134.158.76.115 on Fri May 16 11:12:17 2025; State of the art Synchro 
|
Les performance de la synchro de ThomX au 16 mai 2025 sont:
Le jitter 500MHz Ring 500MHz Linac est de 8ps Sdev et 95% es événement dans 20ps 100 % dans 80ps (quelquesoit
la fréquence de répétion) (Jitter rapide) |
Entered by Nicolas Delerue from 193.55.29.170 on Wed Jun 18 18:02:07 2025; Etude des problèmes de déclenchement des générateurs de retard  
|
La voie 19 du générateur de retard diags était déjà branchée sur le scope (ch1 - jaune)
Branchement de la voie 8 sur le scope (ch 2 vert).
Kicker d'injection sur ch3 (orange) |
VC RC; Redeclanche des DGs 
|
scope (déclenche sur glitch inversé (inférieur à 50ns) CH1
CH1 trigext DeG4 (pris avec 1 "T" scope sur 1MOhm)
CH2 33MHz RI (in trigbox) |
VC; réglage DEG4 --> DEG1
|
Gen4, voie 1 => Gen1,voie2, RF Gun
Gen4, voie 2 => Gen1,voie3, Laser
Gen4, voie 6 => Gen1,voie4, RedPitaya |
VC, ND; Recharge constante synchro 8
|
Les constantes de synchronisation 8 (sans DEG 4) ont été rechargées. Toutes les valeurs sont remises à celles du 8 juillet
2025.