77
Wed Nov 6 16:11:12 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Spherical mirrors at closest position. FSR, finesse and beam size.
The spherical mirrors are at the closest
position to get a FSR ~=33.3435 MHz. Planar
mirrors are at the largest position.
78
Wed Nov 13 14:44:56 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Amplifier output power
The ouput power of the ThomX amplifier
has been measured as a function of the 3rd
stage pumps current (0A is 1st and 2nd stage
79
Wed Nov 13 15:05:18 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Amplifier output power
80
Thu Nov 21 11:37:13 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Onefive Origami 33MHz specs
Beam Size Onefive added
85
Wed Nov 27 13:53:57 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Onefive output power
The pump voltage has been increased few
days ago when looking for a modlock of the
laser.
86
Thu Nov 28 10:40:29 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
CVBG reference and Eric Cormier calculation
The Stretcher is the "D 24-02-II",
it must be used in double path before the
amplifier injection.
87
Tue Feb 4 14:39:56 2020
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Onefive output power
Onefive output power measured today. 3.52
mW with OD1 filter ==> ~35mW.
88
Fri Feb 7 14:46:55 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
We installed the 2 CVBG for compression
after the amplifier.
We used an interferometric technique
89
Wed Feb 12 17:43:43 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
Yesterday, Loic installed a telescope before
CVBG's to reduce the spot size on CVBG's
and reduced the incident angle 0.5-1°
90
Fri Feb 14 09:26:07 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
Yesterday, Loïc put the CVBG's
back to their specified angles.
We used an interferometric technique
91
Fri Feb 14 18:02:37 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Telescope for compressors and ThomX
CVBGs telescope is done with w ~= 1mm.
ThomX telescope is done with w
~= 2.3mm in x and y.
92
Tue Feb 18 12:24:00 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
ThomX Locked with CVBGs
ThomX has been locked with a new telescope
while using compression CVBGs.
Coupling is ~50-55% and lock is stable.
93
Wed Feb 19 17:21:28 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Powerup with 2.5ps pulses
A power up has been performed on ThomX
until 65kW intracavity power. We didn't
see any modes but stored power was really
94
Mon Feb 24 16:28:52 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Beam pulse duration
Last Thursday (20th of February), Loïc
and Titouan realigned the stretcher CVBG
to its nominal angle and they used an interferometric
95
Wed Feb 26 10:38:37 2020
Ronic Chiche
Fixed
info
lasers and optics
Optical room
Optical spectrum analyzer resolution
The Koheras @0.5mW is directly connected
with fibers FC/APC -> FC/PC to the Avantes
optical spectrum analyzer.
96
Wed Feb 26 11:05:09 2020
Ronic Chiche
Fixed
info
lasers and optics
Optical room
Optical spectrum analyzer resolution
Same measurement with Koheras @100mW and
using fiber coupling lenses between Koheras
and Avantes OSA.
97
Wed Feb 26 16:48:02 2020
Ronic Chiche
Fixed
info
lasers and optics
Optical room
Optical spectrum before and after CVBG
Measurement of the optical spectrum with
Avantes OSA before (1st picture) and after
CVBG (2nd picture) with 2nd stage on the
98
Fri Feb 28 09:20:37 2020
Ronic Chiche
Not Fixed
issue
lasers and optics
Optical room
Amplifier laser diodes issue
This is a long time issue for the ThomX
amplifier : on the 4 pumping diodes available,
the 1st diode has a higher temperature than
99
Fri Feb 28 17:44:12 2020
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Pointing stability with CVBG
Yesterday, with Titouan, we made some measurements
on pointing stability of the laser beam after
amplifier and CVBG.
100
Tue Jun 16 13:03:52 2020
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
Finesse measurement after confinement
After 3 months without human presence,
finesse has been measured 3 times with
average optimization: