39
|
Mon Mar 7 14:54:58 2022 |
Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 | Under Process | Problem | Material |
|
RE: Probleme ecran Synthe linac | |
| Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 wrote: |
|
L 'ecran du synthe linac ne fonctionne plus.
Il est possible de se connecter au synthe linac par telnet avec la commande suivante:
$ telnet synthe-b8 5025
Ensuite envoyer les commandes du manuel chapitre 7 page pdf 389.
|
Exemple:
FREQ:CW?
2998550000
SOUR:POW:POW?
18
|
|
40
|
Mon Mar 7 15:24:48 2022 |
Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 | Under Process | Problem | Material |
|
RE: RE: Probleme ecran Synthe linac | |
*RST
SOUR:POW:POW?
-30
SOUR:POW:POW?
-30
FREQ:CW?
1000000000
FREQ:CW 2998550000
SOUR:POW:POW 18
SOUR:POW:POW?
18
FREQ:MODE?
CW
OUTP?
0
OUTP ON
OUTP?
1
| Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 wrote: |
|
| Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 wrote: |
|
L 'ecran du synthe linac ne fonctionne plus.
Il est possible de se connecter au synthe linac par telnet avec la commande suivante:
$ telnet synthe-b8 5025
Ensuite envoyer les commandes du manuel chapitre 7 page pdf 389.
|
Exemple:
FREQ:CW?
2998550000
SOUR:POW:POW?
18
|
|
|
32
|
Fri Feb 4 15:25:47 2022 |
Entered by Nicolas Delerue from 134.158.195.144 on Fri Feb 4 15:25:32 2022 | Fixed | Fix | Timing |
|
Trigger RDPY etait sur SSE | |
Le trigger de la voie 14 du generateur 3 (diags) qui correspond a une redpitya etait sur SSE (tir unique). Il a ete remis sur EXT (mode normal avec declenchement externe). |
|
7
|
Tue Oct 13 12:23:20 2020 |
Entered by Nicolas Delerue from 134.158.195.143 on Tue Oct 13 12:23:01 2020 | Fixed | Fix | Material |
|
addresse IP reglee; Pb IHM | |
Bonjour,
J'ai mis les bonnes adresses IP sur les generateurs de retard et tout teste. Cela fonctionne.
Par contre le DS n'est pas demarre donc l'IHM ne fonctionne toujours pas.
Nicolas
|
|
68
|
Thu Oct 26 16:16:54 2023 |
Entered by Nicolas Delerue from 134.158.195.143 on Thu Oct 26 16:16:39 2023 | | Info | Other |
|
Routage pickup cavite RF => WAC3 | |
Pickup cavite RF puissance incidente <=> Panneau 91501 A1 <=> Baie 9, E2 <=> Baie 5, WAC3, voie 4 |
|
3
|
Fri Jan 31 16:17:43 2020 |
Entered by Nicolas Delerue from 134.158.195.143 on Fri Jan 31 16:17:30 2020 | Fixed | Fix | Timing |
|
Commande declenchement force SSE | |
Pour provoquer un declenchement force du DEG3 il faut regler les canaux a declencher sur SSE
et ensuite envoyer la commande
wget --no-cache -S --post-data 'elem=Run&val=true&end' "http://192.168.229.25/main.php"
C'est equivalent a l'appui de Run/Stop sur l'interfqce web: http://192.168.229.25/ |
|
9
|
Thu Jun 3 18:12:04 2021 |
Entered by Nicolas Delerue from 134.158.195.142 on Thu Jun 3 18:11:47 2021 | | Fix | Other |
|
Config des generateurs de retqrds rechqrgee | |
j'ai rechargee la config par defaut des generateurs de retard (config 9) |
|
113
|
Thu Apr 17 17:24:58 2025 |
Entered by Nicolas Delerue from 134.158.195.142 on Thu Apr 17 17:24:43 2025 | | Info | Timing |
|
Routage 16,7MHz pour camera a balayage | |
Baie 9: B14 =>cable 94545 => baie 34 A5 |
|
112
|
Thu Apr 17 16:54:51 2025 |
Entered by Nicolas Delerue from 134.158.195.142 on Thu Apr 17 16:54:35 2025 | | Info | Timing |
|
Routage 500MHz anneau pour camera a balayage | |
Le 500MHz pour la camera a balayage est injecte sur la voie C9 dans la baie 09, passe par le cable 90542 et arrive sur la voie A4.
Pour l'instant le 500MHz est pris a la place du scope de la baie 9. |
|
27
|
Mon Jan 3 17:01:11 2022 |
Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:00:57 2022 | Fixed | Fix | Material |
|
Synchro redemarree | |
La synchro a ete redemaree avec les reglages de la memoire 6. |
|
28
|
Mon Jan 3 17:14:09 2022 |
Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:00:57 2022 | Fixed | Fix | Material |
|
RE: Synchro redemarree | |
Declenchement OK
| Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:00:57 2022 wrote: |
|
La synchro a ete redemaree avec les reglages de la memoire 6.
|
|
|
64
|
Fri Oct 20 14:29:12 2023 |
Entered by Nicolas Delerue from 134.158.195.142 on Fri Oct 20 14:28:56 2023 | | Info | Other |
|
Synchro for streak camera | |
Signal declencment camera streak: gene 4, canal 9
Routage Streak camera:
Baie 8 <=> Baie 34
E4, A1, A2, A3 <=> B3(N), A1, A2, A3
A1/A1: Declenchement streak camera gene 4, channel 9
E4/B3: 125MHz
A3/A3: 16MHz
A2/A2: Declenchement laser PC gene 4, channel 2
Routage Laser:
Baie 8 <=> Baie 34
E1, E2 (N) <=> B1, B2(N)
E1/B1: 500MHz Li
|
|
106
|
Fri Dec 20 12:03:29 2024 |
Entered by Nicolas Delerue from 134.158.195.142 on Fri Dec 20 12:03:15 2024 | Fixed | Fix | Timing |
|
Added a "diags only" button on Rep rate GUI | |
Two buttons have been added to the repetition rate interface (see attached screen shot):
- "diags only": Will inhibit all channels from the ring and linac delay generators
- "restore linac and ring": Will set all channels of the ring and linac delay generators to External triggering.
A git pull has been done. |
| Attachment 1: Screenshot_from_2024-12-20_12-03-09.png
|
 |
| Attachment 2: 20241220_115912.jpg
|
 |
| Attachment 3: 20241220_115919.jpg
|
 |
|
47
|
Thu Jun 8 13:28:05 2023 |
Entered by Nicolas Delerue from 134.158.195.141 on Thu Jun 8 13:27:52 2023 | Fixed | Fix | Other |
|
Ajout du bouton "phase scan off" sur l'IHM phase.py | |
Le bouton "phase scan off" a ete ajoute sur l'IHM phase.py (faire un git pull pour recuperer la nuvelle version)
|
|
22
|
Fri Oct 29 10:48:11 2021 |
Entered by Moutardier Alexandre from 134.158.195.144 on Fri Oct 29 10:47:58 2021 | Fixed | Fix | Timing |
|
décalage de "seulement" 40µs | |
Suite a un oublis de sauvegarde de la configuration décalé de 100µs, et un redémarrage du ds sim, il a fallu refaire les décalage de retard.
Nicolas trouvant que 100µs était trop, j'ai cherché le minimum de retard possible pour avoir un signal sur la caméra linac.
Après quelque test, j'ai décallé les retard de 40µs et ça focnctionne pour la caméra linac et la caméra laser.
sauvé dans : 20211028_1105_deplacement_trigger_linac_a_40_micro_s.xml |
|
35
|
Mon Feb 14 10:15:26 2022 |
Entered by Moutardier Alexandre from 134.158.195.142 on Mon Feb 14 10:15:13 2022 | Under Process | Fix | Timing |
|
Recette synchro | |
Recette du 01-02-2022 rechargé et sauvé sous le nom : 20220201_reference.xml
Correction d'un bug de lecture de recette dans le script => git push nécésaire pour pouvoir recharger une recette ! |
|
33
|
Fri Feb 4 15:35:49 2022 |
Entered by Moutardier Alexandre from 134.158.195.142 on Fri Feb 4 15:35:36 2022 | | Info | Tests |
|
Test AcqAttrManager | |
DS AcqAttr mannager démarrer correctement.
Générateur de retard Diag : Voies T6, T7, T8 (WAC) mise en SSE
-> Tir sigle shot sur le géné nécéssaire au début
Sinon cela fonctionne.
Retour en config normal. |
|
17
|
Mon Oct 18 14:37:15 2021 |
Entered by Alexandre Moutardier from 134.158.195.144 on Mon Oct 18 14:36:58 2021 | Not Fixed | Problem | Timing |
|
pB taux de répétition machine | |
pB de taux de répétition des signaux de déclenche:
Dans l'IHM le taux de répétition est de 5Hz pour les diags (code décimal 12 )
La relecture de l'automate est conforme au tableau des fréquences (lien code fréquence:https://atrium.in2p3.fr/5da11240-159f-4d7f-ae2e-ba87cd5ed733)
Attention Bit de poid fort Bit 4 et TRUE = 0 et False =1
la mesure du taux de répétition est de 1Hz
=> nous avons donc un pB
Il faudrait vérifier que le tableau des fréquences est bien celui dans le firmware de la CPLD de la carte synchro et que la sortie physique de l'automate soit conforme aux données de l'ATK panel
Alexandre et Vincent |
| Attachment 1: Screenshot_from_2021-10-18_15-02-35.png
|
 |