HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Synchronisation
  Elog synchro, Page 7 of 7  Not logged in ThomX    logo
ID Date Authordown Status Type Category Important Subject Icon
  39   Mon Mar 7 14:54:58 2022 Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022Under ProcessProblemMaterial RE: Probleme ecran Synthe linac 

 

Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 wrote:

L 'ecran du synthe linac ne fonctionne plus.

Il est possible de se connecter au synthe linac par telnet avec la commande suivante:

$ telnet synthe-b8 5025

Ensuite envoyer les commandes du manuel chapitre 7 page pdf 389.

 

Exemple:

FREQ:CW?
2998550000
 

SOUR:POW:POW?
18


 

  40   Mon Mar 7 15:24:48 2022 Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022Under ProcessProblemMaterial RE: RE: Probleme ecran Synthe linac 

*RST
SOUR:POW:POW?
-30
SOUR:POW:POW?  
-30
FREQ:CW?
1000000000
FREQ:CW 2998550000
SOUR:POW:POW 18
SOUR:POW:POW?
18
FREQ:MODE?
CW
OUTP?
0
OUTP ON
OUTP?
1
 

Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 wrote:

 

Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022 wrote:

L 'ecran du synthe linac ne fonctionne plus.

Il est possible de se connecter au synthe linac par telnet avec la commande suivante:

$ telnet synthe-b8 5025

Ensuite envoyer les commandes du manuel chapitre 7 page pdf 389.

 

Exemple:

FREQ:CW?
2998550000
 

SOUR:POW:POW?
18


 

 

  32   Fri Feb 4 15:25:47 2022 Entered by Nicolas Delerue from 134.158.195.144 on Fri Feb 4 15:25:32 2022FixedFixTiming Trigger RDPY etait sur SSE 

Le trigger de la voie 14 du generateur 3 (diags) qui correspond a une redpitya etait sur SSE (tir unique). Il a ete remis sur EXT (mode normal avec declenchement externe).

  7   Tue Oct 13 12:23:20 2020 Entered by Nicolas Delerue from 134.158.195.143 on Tue Oct 13 12:23:01 2020FixedFixMaterial addresse IP reglee; Pb IHM 

Bonjour,

J'ai mis les bonnes adresses IP sur les generateurs de retard et tout teste. Cela fonctionne.

Par contre le DS n'est pas demarre donc l'IHM ne fonctionne toujours pas.

Nicolas

 

 

  68   Thu Oct 26 16:16:54 2023 Entered by Nicolas Delerue from 134.158.195.143 on Thu Oct 26 16:16:39 2023 InfoOther Routage pickup cavite RF => WAC3 

Pickup cavite RF puissance incidente <=> Panneau 91501 A1 <=> Baie 9, E2 <=> Baie 5, WAC3, voie 4

  3   Fri Jan 31 16:17:43 2020 Entered by Nicolas Delerue from 134.158.195.143 on Fri Jan 31 16:17:30 2020FixedFixTiming Commande declenchement force SSE 

Pour provoquer un declenchement force du DEG3 il faut regler les canaux a declencher sur SSE

et ensuite envoyer la commande

wget --no-cache -S --post-data 'elem=Run&val=true&end' "http://192.168.229.25/main.php"

 

C'est equivalent a l'appui de Run/Stop sur l'interfqce web: http://192.168.229.25/

  9   Thu Jun 3 18:12:04 2021 Entered by Nicolas Delerue from 134.158.195.142 on Thu Jun 3 18:11:47 2021 FixOther Config des generateurs de retqrds rechqrgee 

j'ai rechargee la config par defaut des generateurs de retard (config 9)

  113   Thu Apr 17 17:24:58 2025 Entered by Nicolas Delerue from 134.158.195.142 on Thu Apr 17 17:24:43 2025 InfoTiming Routage 16,7MHz pour camera a balayage 

Baie 9: B14 =>cable 94545 => baie 34 A5

  112   Thu Apr 17 16:54:51 2025 Entered by Nicolas Delerue from 134.158.195.142 on Thu Apr 17 16:54:35 2025 InfoTiming Routage 500MHz anneau pour camera a balayage 

Le 500MHz pour la camera a balayage est injecte sur la voie C9 dans la baie 09, passe par le cable 90542 et arrive sur la voie A4.

Pour l'instant le 500MHz est pris a la place du scope de la baie 9.

  27   Mon Jan 3 17:01:11 2022 Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:00:57 2022FixedFixMaterial Synchro redemarree 

La synchro a ete redemaree avec les reglages de la memoire 6.

  28   Mon Jan 3 17:14:09 2022 Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:00:57 2022FixedFixMaterial RE: Synchro redemarree 

Declenchement OK

Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:00:57 2022 wrote:

La synchro a ete redemaree avec les reglages de la memoire 6.

 

  64   Fri Oct 20 14:29:12 2023 Entered by Nicolas Delerue from 134.158.195.142 on Fri Oct 20 14:28:56 2023 InfoOther Synchro for streak camera 

Signal declencment camera streak: gene 4, canal 9

Routage Streak camera:

Baie 8 <=> Baie 34

E4, A1, A2, A3 <=> B3(N), A1, A2, A3

A1/A1: Declenchement streak camera gene 4, channel 9

E4/B3: 125MHz

A3/A3: 16MHz

A2/A2: Declenchement laser PC gene 4, channel 2

Routage Laser:

Baie 8 <=> Baie 34

E1, E2 (N)  <=> B1, B2(N)

E1/B1: 500MHz Li

 

  106   Fri Dec 20 12:03:29 2024 Entered by Nicolas Delerue from 134.158.195.142 on Fri Dec 20 12:03:15 2024FixedFixTiming Added a "diags only" button on Rep rate GUI 

Two buttons have been added to the repetition rate interface (see attached screen shot):

- "diags only": Will inhibit all channels from the ring and linac delay generators

- "restore linac and ring": Will set all channels of the ring and linac delay generators to External triggering.

A git pull has been done.

Attachment 1: Screenshot_from_2024-12-20_12-03-09.png
Screenshot_from_2024-12-20_12-03-09.png
Attachment 2: 20241220_115912.jpg
20241220_115912.jpg
Attachment 3: 20241220_115919.jpg
20241220_115919.jpg
  47   Thu Jun 8 13:28:05 2023 Entered by Nicolas Delerue from 134.158.195.141 on Thu Jun 8 13:27:52 2023FixedFixOther Ajout du bouton "phase scan off" sur l'IHM phase.py 

Le bouton "phase scan off" a ete ajoute sur l'IHM phase.py (faire un git pull pour recuperer la nuvelle version)

 

  22   Fri Oct 29 10:48:11 2021 Entered by Moutardier Alexandre from 134.158.195.144 on Fri Oct 29 10:47:58 2021FixedFixTiming décalage de "seulement" 40µs 

Suite a un oublis de sauvegarde de la configuration décalé de 100µs, et un redémarrage du ds sim, il a fallu refaire les décalage de retard.

Nicolas trouvant que 100µs était trop, j'ai cherché le minimum de retard possible pour avoir un signal sur la caméra linac.

Après quelque test, j'ai décallé les retard de 40µs et ça focnctionne pour la caméra linac et la caméra laser.

sauvé dans : 20211028_1105_deplacement_trigger_linac_a_40_micro_s.xml

  35   Mon Feb 14 10:15:26 2022 Entered by Moutardier Alexandre from 134.158.195.142 on Mon Feb 14 10:15:13 2022Under ProcessFixTiming Recette synchro 

Recette du 01-02-2022 rechargé et sauvé sous le nom : 20220201_reference.xml

Correction d'un bug de lecture de recette dans le script => git push nécésaire pour pouvoir recharger une recette !

  33   Fri Feb 4 15:35:49 2022 Entered by Moutardier Alexandre from 134.158.195.142 on Fri Feb 4 15:35:36 2022 InfoTests Test AcqAttrManager 

DS AcqAttr mannager démarrer correctement.

Générateur de retard Diag : Voies T6, T7, T8 (WAC) mise en SSE

-> Tir sigle shot sur le géné nécéssaire au début

Sinon cela fonctionne.

Retour en config normal.

  17   Mon Oct 18 14:37:15 2021 Entered by Alexandre Moutardier from 134.158.195.144 on Mon Oct 18 14:36:58 2021Not FixedProblemTiming pB taux de répétition machine 

pB de taux de répétition des signaux de déclenche:

Dans l'IHM le taux de répétition est de 5Hz pour les diags (code décimal 12 )

La relecture de l'automate est conforme au tableau des fréquences (lien code fréquence:https://atrium.in2p3.fr/5da11240-159f-4d7f-ae2e-ba87cd5ed733)

Attention Bit de poid fort Bit 4 et TRUE = 0 et False =1

la mesure du taux de répétition est de 1Hz

 

 

=> nous avons donc un pB

 

Il faudrait vérifier que le tableau des fréquences est bien celui dans le firmware de la CPLD de la carte synchro et que la sortie physique de l'automate soit conforme aux données de l'ATK panel

 

Alexandre et Vincent

Attachment 1: Screenshot_from_2021-10-18_15-02-35.png
Screenshot_from_2021-10-18_15-02-35.png
ELOG V3.1.4-395e101