HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Effets dynamiques Anneau Linac RF Codes Lattice
  Notes sur les simulations concernant le Linac de ThomX, Page 1 of 1  Not logged in ThomX    logo
ID Date Authordown Status Type Category Important Subject Icon
  3   Sun Nov 3 13:28:46 2019 Hayg11 InfoAstra , entered from 86.247.100.226 
new test message
please ignore
  4   Wed May 22 16:11:55 2024 Entered by Super Team from 134.158.195.141 on Wed May 22 16:11:40 2024Not FixedInfoEmittance Scans soleno : data  

Dans :

/data/shared/Commissioning_tools/Mesure /

 

./2022/20220412/scan_Isoleno_dim20220412/scandim_Isoleno/scan1/solenoscan_15h12.txt
./2022/20220412/scan_Isoleno_dim20220412/scandim_Isoleno/scan2/solenoscan_15h24.txt
./2022/20220609/scandim_Isoleno/solenoscan_18h59.txt
./2022/20220704/scandim_Isoleno/solenoscan_18h09.txt
./2022/20220704/scandim_soleno_zoom/solenoscan_18h21.txt
./2022/20220704/scan_soleno_iris1/solenoscan_20h45.txt
./2022/20220720/scandim_Isoleno/solenoscan_16h59.txt
./2022/20220720/scandim_Isoleno_zoom/solenoscan_17h10.txt
./20230216/Soleno_YagLI/solenoscan_11h30.txt
./20231024/scandim_Isoleno/solenoscan_16h11.txt
./20231024/solenoscan_16h24.txt
./20231024/scandim_Isolenozoom/solenoscan_16h31.txt
./20231024/scandim_Isolenozoom/solenoscan_16h39.txt
./20231117/scandim_Isoleno/solenoscan_10h36.txt
./20230306/soleno_yag1/Data_large/solenoscan_13h10.txt
./20230306/soleno_yag1/Data_210_240/solenoscan_13h22.txt
./20230703/scandim_Isoleno/scan1/solenoscan_17h07.txt
./20230703/scandim_Isoleno/scan2/solenoscan_17h12.txt
 

  1   Mon Nov 6 16:18:16 2017 Entered by Hayg Guler from 134.158.91.29 on Mon Nov 6 14:50:22 2017FixedInfoOther Dynamique Photo injecteur ThomX, entered from 134.158.91.29 icon1.gif 
Talk de Jacques Haïssinski du 12 Septembre 2017.
Attachment 1: Photo_injecteur_Thomx_JH.pdf
  2   Mon Nov 6 18:22:58 2017 Entered by Harsh Purwar from 134.158.76.165 on Mon Nov 6 18:01:11 2017Under ProcessInfoAstra Asymmetric longitudinal distribution due to mirror charge, entered from 134.158.76.165 icon4.gif 
We observe a peak in the longitudinal distribution 2.0 cm from the photo-cathode (i.e. inside the RF gun) when we include the mirror charge and the peak disappears if we don't consider the mirror charge in the simulations. Attachments: Snapshot of the ASTRA input file (Capture.png). Particle longitudinal distribution at the cathode (lp_0cm.png). Particle long. dist. at z = 2.0 cm from the cathode (lp_mc_sp_2cm.png) considering mirror and space charges, and we see a significant peak on the left. Particle long. dist. at z = 2.0 cm from the cathode (lp_nmc_sp_2cm.png) only with space charge (NOT the mirror charge), and the peak disappears. Normalized electric field for the RF gun considered for these simulations (gun_field.png).
Attachment 1: Capture.PNG
Capture.PNG
Attachment 2: lp_0cm.png
lp_0cm.png
Attachment 3: lp_mc_sp_2cm.png
lp_mc_sp_2cm.png
Attachment 4: lp_nmc_sp_2cm.png
lp_nmc_sp_2cm.png
Attachment 5: gun_field.png
gun_field.png
ELOG V3.1.4-395e101