| ID |
Date |
Author |
Status |
Type |
Category |
Important |
Subject |
Icon |
|
146
|
Fri Nov 15 11:48:52 2024 |
Entered by Nicolas Delerue from 134.158.195.144 on Fri Nov 15 11:48:36 2024 | Reference Solution | Info | BPMs |
|
BPM transmission GUI | |
A GUI to measure the transmission through the BPMs has been developped. It is in the git panneaux at Diags/BPM (a git pull is needed to have access to it).
To lauch it type:
ipython IHM_BPM_ratio.py
You get a window with the interface like in the attached image.
For the measurements to be meaningfull you need to click on "set fixed gain". It will set all the BPms on teh same fixed gain.
Once you are done, it is preferable to revert the BPMs to auto gain by clicking on "set auto gain".
Note: The charge on TL/BPM.03 is higher than on TL/BPM.02 see separate elog entry about this. |
|
133
|
Thu Jul 6 12:10:36 2023 |
Entered by Nicolas Delerue from 134.158.195.143 on Thu Jul 6 12:10:21 2023 | New Solution | Info | BLM |
|
Timing of the fiber oscilloscope | |
The scope reading the ring fibers is currently ER/DG/RAC.06-OSC.01. It is on channel 18 of the Diag delay generator. This channel is labelled "spare camera". I has been added it to diag_delays (will be available after the next git pull).
It was set to -49us with a scope horizontal latency of +42.5us. We changed this to set the chanel delay at -9us with a scope latency of 2.5us. So this should be transparent for all.
|
|
14
|
Fri Jan 31 16:20:01 2020 |
Entered by Nicolas Delerue from 134.158.195.143 on Fri Jan 31 16:19:47 2020 | Fixed | Fix | BPMs |
|
T2TrigCount d'un libera | |
Un script pour connaitre le T2TrigCount d'un libera
panneaux/Diags/BPM/get_BPM_trigcount.py
La commande a mettre dans le DsDiagManager pour un declenchement externe est
wget --no-cache -S --post-data 'elem=Run&val=true&end' "http://192.168.229.25/main.php"
|
|
2
|
Fri Dec 20 15:41:18 2019 |
Entered by Nicolas Delerue from 134.158.195.143 on Fri Dec 20 15:41:03 2019 | Fixed | Fix | Cameras SST |
|
TL/SST.03-CCD and TL/SST.02-CCD started | |
TL/SST.03-CCD and TL/SST.02-CCD have been started.
TL/SST.03-CCD is in the correct configuration (but without light)
TL/SST.02-CCD is next to the SST station, not in the correct configuation.
|
|
119
|
Tue Jan 17 16:26:51 2023 |
Entered by Nicolas Delerue from 134.158.195.142 on Tue Jan 17 16:26:36 2023 | New Solution | Info | Cameras SST |
|
Test vitesse des moteurs | |
Verification de la longueur de deplacement en fonction de la vitesse des moteurs:
Vitesse = 3:
| li/dg/sst.01 |
Pos out:1860.41 |
Pos in:510.04 |
Range:1350.37 |
| tl/dg/sst.01 |
Pos out:-145.38 |
Pos in:0.0 |
Range:-145.38 |
| tl/dg/sst.02 |
Pos out:-144.89 |
Pos in:-0.005 |
Range:-144.885 |
| tl/dg/sst.03 |
Pos out:-144.885 |
Pos in:0.0 |
Range:-144.885 |
| el/dg/sst.01 |
Pos out:-142.5 |
Pos in:-0.16 |
Range:-142.34 |
Vitesse =2:
| li/dg/sst.01 |
Pos out:656.15 |
Pos in:510.12 |
Range:146.03 |
| tl/dg/sst.01 |
Pos out:-145.385 |
Pos in:0.005 |
Range:-145.39 |
| tl/dg/sst.02 |
Pos out:-145.02 |
Pos in:-0.005 |
Range:-145.015 |
| tl/dg/sst.03 |
Pos out:-144.885 |
Pos in:0.095 |
Range:-144.98 |
| el/dg/sst.01 |
Pos out:-142.5 |
Pos in:-0.15 |
Range:-142.35 |
La vitesse recomandée est 2, au delà certains moteurs pas à pas manquent trop de pas. |
|
130
|
Tue Feb 21 17:59:43 2023 |
Entered by Nicolas Delerue from 134.158.195.142 on Tue Feb 21 17:59:26 2023 | New Solution | Fix | Other |
|
Outil pour verifier les derive de la phase RF par rapport a celle du laser | |
J'ai ajouter dans PlateformeIHM un outil "lock phase" qui permet de recaler la phase RF canon vs laser.
Pour l'utiliser cliquer sur "Check phase". Il decale la phase de 52 degrees par rapport a la phase actuelle et prends des mesures quelques degrees avant et apres pour voir ou se situe la chute en charge. Une fois la chute en phase trouvee, il retire 52 degrees et suggere une nouvelle phase de fonctionnement.
Cela evite de devoir le faire a la main (en attendant la retroaction sur la phase en cours d'installation).
|
|
124
|
Thu Feb 16 10:13:59 2023 |
Entered by Nicolas Delerue from 134.158.195.142 on Thu Feb 16 10:13:43 2023 | Under Process | Info | Cameras SST |
|
Test temps reponse IHM SST | |
Suite a un commentaire lors de la reunion technique de ce matin, j'ai fait une verification en salle de controle du temps de reponse des changements de cameras dans l'IHM SST:
Sur client 2 lors du changement de camera le temps de latence est inferieur a 2s.
Sur client1 effectivement, il y a des plantages... Etude en cours.
|
|
125
|
Thu Feb 16 10:26:55 2023 |
Entered by Nicolas Delerue from 134.158.195.142 on Thu Feb 16 10:13:43 2023 | Fixed | Info | Cameras SST |
|
RE: Test temps reponse IHM SST | |
Apres quelques modifications, le temps de reponse sur client 1 de l' IHM SST est inferieur a 4 secondes.
Une nouvelle interface allegee pour les cameras SST est en preparation.
| Entered by Nicolas Delerue from 134.158.195.142 on Thu Feb 16 10:13:43 2023 wrote: |
|
Suite a un commentaire lors de la reunion technique de ce matin, j'ai fait une verification en salle de controle du temps de reponse des changements de cameras dans l'IHM SST:
Sur client 2 lors du changement de camera le temps de latence est inferieur a 2s.
Sur client1 effectivement, il y a des plantages... Etude en cours.
|
|
|
54
|
Mon Jan 3 17:22:04 2022 |
Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:21:51 2022 | Fixed | Fix | Other |
|
Redemarrage Diags | |
J'ai redemarre:
- Les Liberas 1 et 2
- Le chassis des cameras
- Le chassis des RPY
J'ai verifie le declenchement et la lecture de:
- LI/SST.01
- TL/SST.01
- LI/DG/BPM01-LIB-01
- TL/DG/BPM01-LIB-02 (un init manuel dans Jive a ete necessaire pour ce libera)
|
|
Draft
|
Mon Feb 5 14:44:30 2024 |
Entered by Nicolas Delerue from 134.158.195.142 on Mon Feb 5 14:44:15 2024 | | Fix | Cameras SST |
|
En cas d'extinction des SST | |
Si l 'on ne parvient pas a changer le temps d'exposition des CCD dans l 'ancienne interface, sur PlateformeIHM choisir "SST laucnher" puis dans la colonne controls du SST Laucnher, choisir la SST |
|
144
|
Fri Sep 6 13:43:13 2024 |
Entered by Nicolas Delerue from 134.158.195.142 on Fri Sep 6 13:42:59 2024 | | Problem | Cameras SST |
|
Etude declencemenent Basler ACE | |
J'ai regarde le probleme des camera basler ACE avec Pylon.
Il semeblerait que la camera ait une latence de 650us.
Je n'ai pas trouve de reglage permetant de resoudre le probleme. |
|
73
|
Thu Mar 24 17:13:11 2022 |
Entered by ND/VC/SC from 134.158.195.144 on Thu Mar 24 17:12:56 2022 | Under Process | Info | Material |
|
Mesures de charges | |
Mesures de charges:
16h41 moyenne sur 50 tirs
16h57 moyenne sur 1000 tirs
17h03 moyenne sur 1000 tirs
17h11 moyenne sur 1000 tirs
17h16 moyenne sur 10 tirs |
|
18
|
Mon Oct 5 14:06:24 2020 |
Entered by Moutardier from 91.168.92.148 on Mon Oct 5 14:05:55 2020 | Under Process | Fix | BPMs |
|
retour du libera 2 et échange des Libera 2 et 3 | |
Le libera 2 est revenu de maintenance.
Il a était mis à la place du Libéra 3 puis qu'il ont été echangé (attention les etiquettes sur ces 2 Libéra n'ont pas encore été échangées).
Le cc doit encore modifier l'addresse IP et le nom de l'ex Libéra 2 afin qu'il soit utilisable depuis jive. |
|
19
|
Thu Oct 22 11:00:31 2020 |
Entered by Moutardier from 193.55.29.171 on Thu Oct 22 11:00:17 2020 | Under Process | Fix | BPMs |
|
échange des Libera 2 et 3 | |
Les étiquettes des libéra 2 et 3 ont été interchanger de façon a avoir les bonne informations inscrite dessus.
Ainsi nous avons en partant du haut de la baie 5 :
Libéra 3 : 2/3 Ri-C1 (BPM 1 à 4)
Libéra 4 : 1/3 Ri-C1 (BPM 5 à 6) + 1/3 Ri-C1 (BPM 1 à 2)
Libéra 5 : 2/3 Ri-C2 (BPM 3 à 6)
Libéra 2 : TL (BPM 1 à 4)
Libéra 1 : EL + Li
Il reste a verrifier la connection au réseau du Libéra 3 et a faire les branchements des sorties des BPM sur les Libéra 2 et 3. |
|
22
|
Wed Jan 20 16:15:49 2021 |
Entered by Moutardier from 134.158.195.142 on Wed Jan 20 16:15:31 2021 | | Info | Calibrations |
|
Démarrage ds MeanStd | |
Methode pour changer un attribut dans MeanStd et redémarrer le ds :
Sur jive :
dans MeanStd/test/MeanStd/'tmp/DG/MeanStd'/paramètre, modifier "ManagedAttributeList" pour avoir les valeurs voulues.
Sur Astor :
"Kill" le serveur "MeanStd" dans 'Salle de controle'/client2/'Not Controlled' (ATTENTION, les ds Not controlled ne sont pas affiché par défault, il faut double cliquer sur Not Controlled)
Sur un terminal depuis le pc client2 tapper la commande :
/data/shared/MeanStd/MeanStd test &
Sur jive :
Ouvrir l'ATKPanel : MeanStd/test/MeanStd/'tmp/DG/MeanStd'
Lancer une commande start. |
|
23
|
Thu Jan 28 14:17:08 2021 |
Entered by Moutardier from 134.158.195.142 on Thu Jan 28 14:16:54 2021 | Fixed | Info | BLM |
|
Tout les Libéra de nouveau fonctionnels | |
L'échange entre le Libéra 2 et 3 est terminé.
Chacun est de nouveau controlable avec Jive, ainsi tout les Libéra sont fonctionnels.
Dans l'ordre de haut en bas dans la baie 5 nous avont les Libéra : 3 4 5 2 1
Les étiquètes on toutes était modifié aussi pour être les bonnes.
Lorsque j'ai rallumé le Libéra 3, il a fallu que j'ouvre toute les interfaces BPM sur jive pour faire un "Init" car ils étaient tous en alarme (main pas pour le Libéra 2).
Tous les Libéra ont était rééteint apès les tests. |
|
59
|
Tue Jan 25 09:04:06 2022 |
Entered by Moutardier Alexandre from 91.168.92.148 on Tue Jan 25 09:03:43 2022 | | Info | BPMs |
|
A faire sur le BPM du linac | |
La conection du BPM Li/DG/BPM.01 doit être refaite.
Une double permutation (une au niveau du BPM et l'autre entre le patchpanel et le Libera) permet actuelement d'avoir un fonctionnement normal du BPM, mais il serait préférable de normaliser les configurations de cablage.
| |
Etat actuel |
Etat préférentiel |
|
| Sur le Libera |
|
|
|
| Sur le patch panel libera |
|
|
première permutation |
| Sur le patch panel BPM |
|
|
|
| code couleur câble |
|
|
seconde permutation |
| Sur le BPM |
|
Côté
Laser
|
Haut |
Côté
anneau |
Bas |
|
|
Côté
laser
|
Haut |
Côté
anneau
|
Bas |
|
|
La modification nécésite la clé dynamometrique. |
|
63
|
Fri Feb 4 10:24:42 2022 |
Entered by Moutardier Alexandre from 91.168.92.148 on Tue Jan 25 09:03:43 2022 | Fixed | Fix | BPMs |
|
RE: Faire sur le BPM du linac | |
Changement de cablage :
Fait, modification transparente pour les mesure.
| |
Etat actuel |
| Sur le Libera |
|
| Sur le patch panel libera |
|
| Sur le patch panel BPM |
|
| code couleur câble |
|
| Sur le BPM |
|
Côté
laser
|
Haut |
Côté
anneau
|
Bas |
|
| Entered by Moutardier Alexandre from 91.168.92.148 on Tue Jan 25 09:03:43 2022 wrote: |
|
La conection du BPM Li/DG/BPM.01 doit être refaite.
Une double permutation (une au niveau du BPM et l'autre entre le patchpanel et le Libera) permet actuelement d'avoir un fonctionnement normal du BPM, mais il serait préférable de normaliser les configurations de cablage.
| |
Etat actuel |
Etat préférentiel |
|
| Sur le Libera |
|
|
|
| Sur le patch panel libera |
|
|
première permutation |
| Sur le patch panel BPM |
|
|
|
| code couleur câble |
|
|
seconde permutation |
| Sur le BPM |
|
Côté
Laser
|
Haut |
Côté
anneau |
Bas |
|
|
Côté
laser
|
Haut |
Côté
anneau
|
Bas |
|
|
La modification nécésite la clé dynamometrique.
|
|
|
79
|
Tue Apr 12 10:16:35 2022 |
Entered by Moutardier Alexandre from 91.168.92.148 on Tue Apr 12 10:16:22 2022 | | Info | BPMs |
|
Verification calibration BPM | |
Verification de la calibration des BPM :
Les valeurs de l'ATKPannel sont coforme a celle du fichier de configuration ($HOME_IHM/Diags/BPM/ThomX_BPM_calibration.csv) |
|
85
|
Mon Jul 25 15:14:52 2022 |
Entered by Moutardier Alexandre from 91.168.92.148 on Mon Jul 25 15:14:39 2022 | | Problem | Cameras SST |
|
Alarme moteur | |
Les moteur des station SST passe en "alarm" par moment pendant quelque second.
Il s'agit d'une alarme de temperature. Il faudra guetter pour s'assurer qu'il n'y a pas de probleme de surchauffe et il fauraut eteindre les moteurs de temps en temps. |