HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Diagnostiques
  elog des diags., Page 6 of 8  Not logged in ThomX    logo
ID Date Authordown Status Type Category Important Subject Icon
  146   Fri Nov 15 11:48:52 2024 Entered by Nicolas Delerue from 134.158.195.144 on Fri Nov 15 11:48:36 2024Reference SolutionInfoBPMs BPM transmission GUI 

A GUI to measure the transmission through the BPMs has been developped. It is in the git panneaux at Diags/BPM (a git pull is needed to have access to it).

To lauch it type:

ipython IHM_BPM_ratio.py

You get a window with the interface like in the attached image.

For the measurements to be meaningfull you need to click on "set fixed gain". It will set all the BPms on teh same fixed gain.

Once you are done, it is preferable to revert the BPMs to auto gain by clicking on "set auto gain".

Note: The charge on TL/BPM.03 is higher than on TL/BPM.02 see separate elog entry about this.

  133   Thu Jul 6 12:10:36 2023 Entered by Nicolas Delerue from 134.158.195.143 on Thu Jul 6 12:10:21 2023New SolutionInfoBLM Timing of the fiber oscilloscope 

The scope reading the ring fibers is currently ER/DG/RAC.06-OSC.01.  It is on channel 18 of the Diag delay generator. This channel is labelled "spare camera". I has been added it to diag_delays (will be available after the next git pull).

It was set to -49us with a scope horizontal latency of +42.5us. We changed this to set the chanel delay at -9us with a scope latency of 2.5us. So this should be transparent for all.
 

  14   Fri Jan 31 16:20:01 2020 Entered by Nicolas Delerue from 134.158.195.143 on Fri Jan 31 16:19:47 2020FixedFixBPMs T2TrigCount d'un libera 

Un script pour connaitre le T2TrigCount d'un libera

panneaux/Diags/BPM/get_BPM_trigcount.py
 

La commande a mettre dans le DsDiagManager pour un declenchement externe est

wget --no-cache -S --post-data 'elem=Run&val=true&end' "http://192.168.229.25/main.php"

 

  2   Fri Dec 20 15:41:18 2019 Entered by Nicolas Delerue from 134.158.195.143 on Fri Dec 20 15:41:03 2019FixedFixCameras SST TL/SST.03-CCD and TL/SST.02-CCD started 

TL/SST.03-CCD and TL/SST.02-CCD have been started.

TL/SST.03-CCD is in the correct configuration (but without light)

TL/SST.02-CCD is next to the SST station, not in the correct configuation.

 

  119   Tue Jan 17 16:26:51 2023 Entered by Nicolas Delerue from 134.158.195.142 on Tue Jan 17 16:26:36 2023New SolutionInfoCameras SST Test vitesse des moteurs 

Verification de la longueur de deplacement en fonction de la vitesse des moteurs:

Vitesse = 3:

li/dg/sst.01 Pos out:1860.41 Pos in:510.04 Range:1350.37
tl/dg/sst.01 Pos out:-145.38 Pos in:0.0 Range:-145.38
tl/dg/sst.02 Pos out:-144.89 Pos in:-0.005 Range:-144.885
tl/dg/sst.03 Pos out:-144.885 Pos in:0.0 Range:-144.885
el/dg/sst.01 Pos out:-142.5 Pos in:-0.16 Range:-142.34

Vitesse =2:

li/dg/sst.01 Pos out:656.15 Pos in:510.12 Range:146.03
tl/dg/sst.01 Pos out:-145.385 Pos in:0.005 Range:-145.39
tl/dg/sst.02 Pos out:-145.02 Pos in:-0.005 Range:-145.015
tl/dg/sst.03 Pos out:-144.885 Pos in:0.095 Range:-144.98
el/dg/sst.01 Pos out:-142.5 Pos in:-0.15 Range:-142.35

 

La vitesse recomandée est 2, au delà certains moteurs pas à pas manquent trop de pas.

  130   Tue Feb 21 17:59:43 2023 Entered by Nicolas Delerue from 134.158.195.142 on Tue Feb 21 17:59:26 2023New SolutionFixOther Outil pour verifier les derive de la phase RF par rapport a celle du laser 

J'ai ajouter dans PlateformeIHM un outil "lock phase" qui permet de recaler la phase RF canon vs laser.

Pour l'utiliser cliquer sur "Check phase". Il decale la phase de 52 degrees par rapport a la phase actuelle et prends des mesures quelques degrees avant et apres pour voir ou se situe la chute en charge. Une fois la chute en phase trouvee, il retire 52 degrees et suggere une nouvelle phase de fonctionnement.

Cela evite de devoir le faire a la main (en attendant la retroaction sur la phase en cours d'installation).

 

 

  124   Thu Feb 16 10:13:59 2023 Entered by Nicolas Delerue from 134.158.195.142 on Thu Feb 16 10:13:43 2023Under ProcessInfoCameras SST Test temps reponse IHM SST 

Suite a un commentaire lors de la reunion technique de ce matin, j'ai fait une verification en salle de controle du temps de reponse des changements de cameras dans l'IHM SST:

Sur client 2 lors du changement de camera le temps de latence est inferieur a 2s.

Sur client1 effectivement, il y a des plantages...  Etude en cours.

 

  125   Thu Feb 16 10:26:55 2023 Entered by Nicolas Delerue from 134.158.195.142 on Thu Feb 16 10:13:43 2023FixedInfoCameras SST RE: Test temps reponse IHM SST 

Apres quelques modifications, le temps de reponse sur client 1 de l' IHM SST est inferieur a 4 secondes.

Une nouvelle interface allegee pour les cameras SST est en preparation. 

Entered by Nicolas Delerue from 134.158.195.142 on Thu Feb 16 10:13:43 2023 wrote:

Suite a un commentaire lors de la reunion technique de ce matin, j'ai fait une verification en salle de controle du temps de reponse des changements de cameras dans l'IHM SST:

Sur client 2 lors du changement de camera le temps de latence est inferieur a 2s.

Sur client1 effectivement, il y a des plantages...  Etude en cours.

 

 

  54   Mon Jan 3 17:22:04 2022 Entered by Nicolas Delerue from 134.158.195.142 on Mon Jan 3 17:21:51 2022FixedFixOther Redemarrage Diags 

J'ai redemarre:

- Les Liberas 1 et 2

- Le chassis des cameras

- Le chassis des RPY

J'ai verifie le declenchement et la lecture de:

- LI/SST.01

- TL/SST.01

- LI/DG/BPM01-LIB-01

- TL/DG/BPM01-LIB-02 (un init manuel dans Jive a ete necessaire pour ce libera)

 

  Draft   Mon Feb 5 14:44:30 2024 Entered by Nicolas Delerue from 134.158.195.142 on Mon Feb 5 14:44:15 2024 FixCameras SST En cas d'extinction des SST 

Si l 'on ne parvient pas a changer le temps d'exposition des CCD dans l 'ancienne interface, sur PlateformeIHM choisir "SST laucnher" puis dans la colonne controls du SST Laucnher, choisir la SST  

  144   Fri Sep 6 13:43:13 2024 Entered by Nicolas Delerue from 134.158.195.142 on Fri Sep 6 13:42:59 2024 ProblemCameras SST Etude declencemenent Basler ACE 

J'ai regarde le probleme des camera basler ACE avec Pylon.

Il semeblerait que la camera ait une latence de 650us.

Je n'ai pas trouve de reglage permetant de resoudre le probleme.

  73   Thu Mar 24 17:13:11 2022 Entered by ND/VC/SC from 134.158.195.144 on Thu Mar 24 17:12:56 2022Under ProcessInfoMaterial Mesures de charges 

Mesures de charges:

16h41 moyenne sur 50 tirs

16h57 moyenne sur 1000 tirs

17h03 moyenne sur 1000 tirs

17h11 moyenne sur 1000 tirs

17h16 moyenne sur 10 tirs

  18   Mon Oct 5 14:06:24 2020 Entered by Moutardier from 91.168.92.148 on Mon Oct 5 14:05:55 2020Under ProcessFixBPMs retour du libera 2 et échange des Libera 2 et 3 

Le libera 2 est revenu de maintenance.

Il a était mis à la place du Libéra 3 puis qu'il ont été echangé (attention les etiquettes sur ces 2 Libéra n'ont pas encore été échangées).

Le cc doit encore modifier l'addresse IP et le nom de l'ex Libéra 2 afin qu'il soit utilisable depuis jive.

  19   Thu Oct 22 11:00:31 2020 Entered by Moutardier from 193.55.29.171 on Thu Oct 22 11:00:17 2020Under ProcessFixBPMs échange des Libera 2 et 3 

Les étiquettes des libéra 2 et 3 ont été interchanger de façon a avoir les bonne informations inscrite dessus.

Ainsi nous avons en partant du haut de la baie 5 :
Libéra 3 : 2/3 Ri-C1 (BPM 1 à 4)
Libéra 4 : 1/3 Ri-C1 (BPM 5 à 6) + 1/3 Ri-C1 (BPM 1 à 2)
Libéra 5 : 2/3 Ri-C2 (BPM 3 à 6)
Libéra 2 : TL (BPM 1 à 4)
Libéra 1 : EL + Li

Il reste a verrifier la connection au réseau du Libéra 3 et a faire les branchements des sorties des BPM sur les Libéra 2 et 3.

  22   Wed Jan 20 16:15:49 2021 Entered by Moutardier from 134.158.195.142 on Wed Jan 20 16:15:31 2021 InfoCalibrations Démarrage ds MeanStd 

Methode pour changer un attribut dans MeanStd  et redémarrer le ds :

Sur jive :
dans  MeanStd/test/MeanStd/'tmp/DG/MeanStd'/paramètre, modifier "ManagedAttributeList" pour avoir les valeurs voulues.

Sur Astor :
"Kill" le serveur "MeanStd" dans 'Salle de controle'/client2/'Not Controlled' (ATTENTION, les ds Not controlled ne sont pas affiché par défault, il faut double cliquer sur Not Controlled)

Sur un terminal depuis le pc client2 tapper la commande :
/data/shared/MeanStd/MeanStd test &

Sur jive :
Ouvrir l'ATKPanel : MeanStd/test/MeanStd/'tmp/DG/MeanStd'
Lancer une commande start.

  23   Thu Jan 28 14:17:08 2021 Entered by Moutardier from 134.158.195.142 on Thu Jan 28 14:16:54 2021FixedInfoBLM Tout les Libéra de nouveau fonctionnels 

L'échange entre le Libéra 2 et 3 est terminé.
Chacun est de nouveau controlable avec Jive, ainsi tout les Libéra sont fonctionnels.

Dans l'ordre de haut en bas dans la baie 5 nous avont les Libéra : 3 4 5 2 1
Les étiquètes on toutes était modifié aussi pour être les bonnes.

Lorsque j'ai rallumé le Libéra 3, il a fallu que j'ouvre toute les interfaces BPM sur jive pour faire un "Init" car ils étaient tous en alarme (main pas pour le Libéra 2).

Tous les Libéra ont était rééteint apès les tests.

  59   Tue Jan 25 09:04:06 2022 Entered by Moutardier Alexandre from 91.168.92.148 on Tue Jan 25 09:03:43 2022 InfoBPMs A faire sur le BPM du linac 

La conection du BPM Li/DG/BPM.01 doit être refaite.

Une double permutation (une au niveau du BPM et l'autre entre le patchpanel et le Libera) permet actuelement d'avoir un fonctionnement normal du BPM, mais il serait préférable de normaliser les configurations de cablage.

  Etat actuel Etat préférentiel  
Sur le Libera
A B C D
A B C D
 
Sur le patch panel libera
A4 A1 A2 A3
A1 A2 A3 A4
première permutation
Sur le patch panel BPM
D A B C
A B C D
 
code couleur câble

Rouge

Blanc Bleu

Jaune

Blanc Bleu Jaune Rouge
seconde permutation
Sur le BPM

Côté
Laser

Haut Côté
anneau
Bas

Côté
laser

Haut

Côté
anneau

Bas

 

La modification nécésite la clé dynamometrique.

  63   Fri Feb 4 10:24:42 2022 Entered by Moutardier Alexandre from 91.168.92.148 on Tue Jan 25 09:03:43 2022FixedFixBPMs RE: Faire sur le BPM du linac 

Changement de cablage :

Fait, modification transparente pour les mesure.

  Etat actuel
Sur le Libera
A B C D
Sur le patch panel libera
A1 A2 A3 A4
Sur le patch panel BPM
A B C D
code couleur câble
Blanc Bleu Jaune Rouge
Sur le BPM

Côté
laser

Haut

Côté
anneau

Bas

 

Entered by Moutardier Alexandre from 91.168.92.148 on Tue Jan 25 09:03:43 2022 wrote:

La conection du BPM Li/DG/BPM.01 doit être refaite.

Une double permutation (une au niveau du BPM et l'autre entre le patchpanel et le Libera) permet actuelement d'avoir un fonctionnement normal du BPM, mais il serait préférable de normaliser les configurations de cablage.

  Etat actuel Etat préférentiel  
Sur le Libera
A B C D
A B C D
 
Sur le patch panel libera
A4 A1 A2 A3
A1 A2 A3 A4
première permutation
Sur le patch panel BPM
D A B C
A B C D
 
code couleur câble

Rouge

Blanc Bleu

Jaune

Blanc Bleu Jaune Rouge
seconde permutation
Sur le BPM

Côté
Laser

Haut Côté
anneau
Bas

Côté
laser

Haut

Côté
anneau

Bas

 

La modification nécésite la clé dynamometrique.

 

  79   Tue Apr 12 10:16:35 2022 Entered by Moutardier Alexandre from 91.168.92.148 on Tue Apr 12 10:16:22 2022 InfoBPMs Verification calibration BPM 

Verification de la calibration des BPM :

Les valeurs de l'ATKPannel sont coforme a celle du fichier de configuration ($HOME_IHM/Diags/BPM/ThomX_BPM_calibration.csv)

  85   Mon Jul 25 15:14:52 2022 Entered by Moutardier Alexandre from 91.168.92.148 on Mon Jul 25 15:14:39 2022 ProblemCameras SST Alarme moteur 

Les moteur des station SST passe en "alarm" par moment pendant quelque second.

Il s'agit d'une alarme de temperature. Il faudra guetter pour s'assurer qu'il n'y a pas de probleme de surchauffe et il fauraut eteindre les moteurs de temps en temps.

ELOG V3.1.4-395e101