432
|
Wed Apr 6 11:32:25 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Wed Apr 6 11:32:06 2022 | | Info | Aimants |
|
intervention sur CC EP | |
Intervention términée sur le EP |
|
61
|
Tue Sep 7 12:09:17 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Tue Sep 7 12:08:31 2021 | | Linac | Linac Commissionning |
|
| |
Lundi 6/09: Le réseau Thomx est sous SF6, le refroidissement du réseau est en fonctionnement
Le modulateur/klystron est utilisable pour le conditionnement
La commande pour l'intervention de Scandinova est partie, "possibilité" d'intervention de leur part Vendredi 10/09
|
|
193
|
Tue Nov 30 11:52:44 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Tue Nov 30 11:52:02 2021 | Not Fixed | Problem | Linac Commissionning |
|
| |
Après avoir exécuter des opérations demandées par mon interlocuteur de Scandinova pour remédier au pb d'interlock ( tjs le même ) du modulateur, j'ai demandé ce matin une intervention ( payante ) sur place de Scandinova pour trouver une solution, j'attends la réponse à ma demande |
|
400
|
Tue Mar 15 08:55:41 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Tue Mar 15 08:55:25 2022 | | Shift summary | RF D1 |
|
| |
Démarrage Modulateur et chillers |
|
393
|
Tue Mar 8 17:12:10 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Tue Mar 8 17:11:52 2022 | | Shift summary | RF D1 |
|
| |
Mise en arrêt modulateur et chillers |
|
58
|
Tue Jul 27 10:20:32 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Tue Jul 27 10:20:02 2021 | | Shift summary | Linac Commissionning |
|
| |
J'ai oublié de préciser: le problème apparu le lundi 26/07 ( fonctionnement modulateur/HF demandé pour la section )
Maher |
|
57
|
Tue Jul 27 10:15:39 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Tue Jul 27 10:15:11 2021 | | Shift summary | Linac Commissionning |
|
| |
J'ai contacté Scandinova pour ce problème, j'ai eu un retour et j'ai envoyé les informations demandés, j'attends leur consignes en retour
Maher |
|
660
|
Tue Jan 3 17:06:05 2023 |
Entered by Maher OMEICH from 134.158.91.212 on Tue Jan 3 17:05:44 2023 | | Fix | Infra |
|
| |
16h45 Vidange de l'eau fosse nord |
|
62
|
Thu Sep 9 09:23:27 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Thu Sep 9 09:23:03 2021 | | Info | RF D1 |
|
intervention Scandinova | |
Bonjour
Demain vendredi 10/09 aura lieu une intervention par Scandinova sur le modulateur |
|
628
|
Thu Nov 24 10:14:45 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Thu Nov 24 10:14:31 2022 | | Problem | RF D1 |
|
| |
J'ai un problème sur le frigo des chillers section et canon qui ne refroidie pas, je contacte la socièté Réglochill
Maher |
|
627
|
Thu Nov 24 09:43:12 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Thu Nov 24 09:42:54 2022 | | Fix | RF D1 |
|
pour info | |
Démarrage de chauffage klystron après mesure du filament kly. suite à la coupure d'hier ( par eau ): le modulateur etait en fonctionnement ( en TRIG ) pour tester le klystron remplacer la semaine dernière, ces tests ont commencé lundi dernier, mardi et mercredi ( jusqu'à la coupure d'eau )
Maher |
|
317
|
Thu Feb 10 15:48:32 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Thu Feb 10 15:48:04 2022 | | Fix | RF D1 |
|
résumé de l'intervention Scandinova | |
Bonjour
Voici le resumé de l'intervention Scandinova tiré du rapport de l'intervention du 07/02/2022 à 09/02/2022
***********************************
Summary of Work
Replaced EP2316-0008 module
Increased filters on HIU for Standby and HV
Increased filter for IntCom interlock
Suggested some mesh to added between Klystron and rack for EMC protection
Corrected some software parameters relating to filament and SPS to increase functionality
Reduced filters for water flow switches due to glitching averaging
A 24h Long Run was carried out. Modulator kept in HV for 24h prior
Conclusion
Problem did not occur while on site, actions taken to reduce the risk of unneccessary interlocks were taken
***************************************
Cordialement
Maher |
|
197
|
Thu Dec 2 10:38:44 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Thu Dec 2 10:38:07 2021 | | Anneau | Aimants |
|
intervention Soleil | |
Bonjour, Patrick Alexandre et Didier Muller ( Soleil ) viendrons demain Vendredi 03/12 toute l'après midi, j'aurai plus d'info aujourd'hui concernant la journée de la semaine prochaine. |
|
71
|
Mon Sep 20 10:55:40 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Sep 20 10:55:19 2021 | | Problem | Linac Commissionning |
|
panne modulateur | |
Ce matin ( lundi 20/09 ) l'interlock modulateur IntComm\Input missing est réapparu coupant le modulateur qui était prêt à fonctionner, j'ai envoyé un mail à Scandinova pour prévenir et demander une expertise. |
|
190
|
Mon Nov 29 10:18:01 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 29 10:17:44 2021 | Not Fixed | Problem | Linac Commissionning |
|
| |
Ce matin j'ai eu plusieurs interlock modulateur
Maher |
|
164
|
Mon Nov 15 10:22:52 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 10:22:36 2021 | Not Fixed | Problem | Linac Commissionning |
|
| |
re-Bonjour
une remarque: quand vous appuiez par erreur sur les boutons rouges qui se trouvent sur les montants des portes ( entrées casemate ) prièrre de les retirés et ne pas les laissés enfoncés car ça empêche de faire la ronde
Merci
Maher
|
|
162
|
Mon Nov 15 09:20:24 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 09:20:04 2021 | Not Fixed | Problem | Linac Commissionning |
|
IHM | |
Bonjour,
la consigne dans l'IHM RF ne fonctionne pas
Maher |
|
163
|
Mon Nov 15 09:41:50 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 09:20:04 2021 | Not Fixed | Problem | Linac Commissionning |
|
RE: IHM | |
Ça doit être bon maintenant
| Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 09:20:04 2021 wrote: |
|
Bonjour,
la consigne dans l'IHM RF ne fonctionne pas
Maher
|
|
|
408
|
Mon Mar 21 14:45:35 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Mar 21 14:45:17 2022 | | Shift summary | Linac Commissionning |
|
| |
( 10h00 ) Démarrage modulateur et refroidissement, fermuture casemate et zone modulateur
|
|
398
|
Mon Mar 14 13:57:12 2022 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Mar 14 13:56:48 2022 | | Info | RF D1 |
|
| |
Bonjour,
Je recommande de mettre une consigne de tension modulateur de 1000 V au démarrage puis monter à la valeur de 1090 V afin d'éviter un réfléchi au démarrage à froid
Maher |