ID Date Authordown Status Type Category Important Subject Icon
  432   Wed Apr 6 11:32:25 2022 Entered by Maher OMEICH from 134.158.91.212 on Wed Apr 6 11:32:06 2022 InfoAimants intervention sur CC EP 

Intervention términée sur le EP

  61   Tue Sep 7 12:09:17 2021 Entered by Maher OMEICH from 134.158.91.212 on Tue Sep 7 12:08:31 2021 LinacLinac Commissionning   

Lundi 6/09: Le réseau Thomx est sous SF6, le refroidissement du réseau est en fonctionnement

Le modulateur/klystron est utilisable pour le conditionnement

La commande pour l'intervention de Scandinova est partie, "possibilité" d'intervention de leur part Vendredi 10/09

 

 

 

  193   Tue Nov 30 11:52:44 2021 Entered by Maher OMEICH from 134.158.91.212 on Tue Nov 30 11:52:02 2021Not FixedProblemLinac Commissionning   

Après avoir exécuter des opérations demandées par mon interlocuteur de Scandinova pour remédier au pb d'interlock ( tjs le même ) du modulateur, j'ai demandé ce matin une intervention ( payante ) sur place de Scandinova pour trouver une solution, j'attends la réponse à ma demande

  400   Tue Mar 15 08:55:41 2022 Entered by Maher OMEICH from 134.158.91.212 on Tue Mar 15 08:55:25 2022 Shift summaryRF D1   

Démarrage Modulateur et chillers

  393   Tue Mar 8 17:12:10 2022 Entered by Maher OMEICH from 134.158.91.212 on Tue Mar 8 17:11:52 2022 Shift summaryRF D1   

Mise en arrêt modulateur et chillers

  58   Tue Jul 27 10:20:32 2021 Entered by Maher OMEICH from 134.158.91.212 on Tue Jul 27 10:20:02 2021 Shift summaryLinac Commissionning   

J'ai oublié de préciser: le problème apparu le lundi 26/07 ( fonctionnement modulateur/HF demandé pour la section )

Maher

  57   Tue Jul 27 10:15:39 2021 Entered by Maher OMEICH from 134.158.91.212 on Tue Jul 27 10:15:11 2021 Shift summaryLinac Commissionning   

J'ai contacté Scandinova pour ce problème, j'ai eu un retour et j'ai envoyé les informations demandés, j'attends leur consignes en retour

Maher

  660   Tue Jan 3 17:06:05 2023 Entered by Maher OMEICH from 134.158.91.212 on Tue Jan 3 17:05:44 2023 FixInfra   

16h45 Vidange de l'eau fosse nord

  62   Thu Sep 9 09:23:27 2021 Entered by Maher OMEICH from 134.158.91.212 on Thu Sep 9 09:23:03 2021 InfoRF D1 intervention Scandinova 

Bonjour

Demain vendredi 10/09 aura lieu une intervention par Scandinova sur le modulateur

  628   Thu Nov 24 10:14:45 2022 Entered by Maher OMEICH from 134.158.91.212 on Thu Nov 24 10:14:31 2022 ProblemRF D1   

J'ai un problème sur le frigo des chillers section et canon qui ne refroidie pas, je contacte la socièté Réglochill

Maher

  627   Thu Nov 24 09:43:12 2022 Entered by Maher OMEICH from 134.158.91.212 on Thu Nov 24 09:42:54 2022 FixRF D1 pour info 

Démarrage de chauffage klystron après mesure du filament kly. suite à la coupure d'hier ( par eau ): le modulateur etait en fonctionnement ( en TRIG ) pour tester le klystron remplacer la semaine dernière, ces tests ont commencé lundi dernier, mardi et mercredi ( jusqu'à la coupure d'eau )

Maher

  317   Thu Feb 10 15:48:32 2022 Entered by Maher OMEICH from 134.158.91.212 on Thu Feb 10 15:48:04 2022 FixRF D1 résumé de l'intervention Scandinova 

Bonjour

Voici le resumé de l'intervention Scandinova tiré du rapport de l'intervention du 07/02/2022 à 09/02/2022

***********************************

Summary of Work

Replaced EP2316-0008 module

Increased filters on HIU for Standby and HV

Increased filter for IntCom interlock

Suggested some mesh to added between Klystron and rack for EMC protection

Corrected some software parameters relating to filament and SPS to increase functionality

Reduced filters for water flow switches due to glitching averaging

A 24h Long Run was carried out. Modulator kept in HV for 24h prior

Conclusion

Problem did not occur while on site, actions taken to reduce the risk of unneccessary interlocks were taken

***************************************

Cordialement

Maher

  197   Thu Dec 2 10:38:44 2021 Entered by Maher OMEICH from 134.158.91.212 on Thu Dec 2 10:38:07 2021 AnneauAimants intervention Soleil 

Bonjour, Patrick Alexandre et Didier Muller ( Soleil ) viendrons demain Vendredi 03/12 toute l'après midi, j'aurai plus d'info aujourd'hui concernant la journée de la semaine prochaine.

  71   Mon Sep 20 10:55:40 2021 Entered by Maher OMEICH from 134.158.91.212 on Mon Sep 20 10:55:19 2021 ProblemLinac Commissionning panne modulateur 

Ce matin ( lundi 20/09 ) l'interlock modulateur IntComm\Input missing est réapparu coupant le modulateur qui était prêt à fonctionner, j'ai envoyé un mail à Scandinova pour prévenir et demander une expertise.

  190   Mon Nov 29 10:18:01 2021 Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 29 10:17:44 2021Not FixedProblemLinac Commissionning   

Ce matin j'ai eu plusieurs interlock modulateur

Maher

  164   Mon Nov 15 10:22:52 2021 Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 10:22:36 2021Not FixedProblemLinac Commissionning   

re-Bonjour

une remarque: quand vous appuiez par erreur sur les boutons rouges qui se trouvent sur les montants des portes ( entrées casemate ) prièrre de les retirés et ne pas les laissés enfoncés car ça empêche de faire la ronde

Merci

Maher

 

  162   Mon Nov 15 09:20:24 2021 Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 09:20:04 2021Not FixedProblemLinac Commissionning IHM  

Bonjour,

la consigne dans l'IHM RF ne fonctionne pas

Maher

  163   Mon Nov 15 09:41:50 2021 Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 09:20:04 2021Not FixedProblemLinac Commissionning RE: IHM  

Ça doit être bon maintenant

Entered by Maher OMEICH from 134.158.91.212 on Mon Nov 15 09:20:04 2021 wrote:

Bonjour,

la consigne dans l'IHM RF ne fonctionne pas

Maher

 

  408   Mon Mar 21 14:45:35 2022 Entered by Maher OMEICH from 134.158.91.212 on Mon Mar 21 14:45:17 2022 Shift summaryLinac Commissionning   

( 10h00 ) Démarrage modulateur et refroidissement, fermuture casemate et zone modulateur

 

  398   Mon Mar 14 13:57:12 2022 Entered by Maher OMEICH from 134.158.91.212 on Mon Mar 14 13:56:48 2022 InfoRF D1   

Bonjour,

Je recommande de mettre une consigne de tension modulateur de 1000 V au démarrage puis monter à la valeur de 1090 V afin d'éviter un réfléchi au démarrage à froid

Maher