41
Wed Jun 12 12:07:11 2019
Loïc Amoudry
Fixed
report
mechanics | lasers and optics
Other
Amplifier mission Bordeaux
M² mesuré à 10W.
M²x = 1.17
M²y = 1.14
42
Wed Jun 12 17:49:20 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Polarization
Polariztion measured with Input vertically/horizontally polarized
(~100% DOLP)
- Transmission (P4) locked on cavity
47
Thu Jul 4 18:28:55 2019
Loïc Amoudry
Fixed
issue
lasers and optics
Optical room
Onefive 33MHz unmodelocked
Oscillator randomly unmodelocked on 3rd
july afternoon (during oscillator power
measurement, maybe a reflection from the
48
Thu Jul 4 18:30:39 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
2nd stage output power validated
Onefive output power : 28mW
Power before fiber injection :
7.8mW
49
Mon Jul 29 17:15:35 2019
Loïc Amoudry
Fixed
info
mechanics | lasers and optics
Optical room
Spin coater air supply removed and front panel changed
Spin coater firstly needed vacuum and air
supply. The air supply being useless for
our experiments, it has been disabled.
55
Tue Sep 3 18:06:29 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Mirrors sent to LMA
Mirrors have been sent today to LMA for
cleaning and maybe annealing (recuit). 3
ULE of ThomX and the fused silicate for injection
56
Fri Sep 6 14:48:14 2019
Loïc Amoudry
Fixed
report
mechanics | vacuum
Optical room
Primary vacuum to check dust
The cavity has been cleaned then put under
primary vacuum (primary pump without vacuum
flow control). Dusts presence was checked
57
Fri Sep 6 14:59:00 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
LMA cleaning technique
Christophe MICHEL told us more precise
informations about spin coater cleaning.
They always clean with pur water
58
Thu Sep 12 16:19:26 2019
Loïc Amoudry
Fixed
report
mechanics | lasers and optics
Optical room
Cavity dust source check
Several experiments have been done in order
to check the potential source of dust in
the ThomX cavity. For each step, we look
60
Fri Sep 27 10:43:17 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
New Suprasil mirror from LMA
19/09/2019 : email from Chrisophe Michel
about AR coating of LMA mirrors after reading
that Ta2O5 layers can be damaged in vacuum
62
Mon Sep 30 11:20:48 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Diffusion ULE spherical mirror (S3) vs Fused Silicate injection planar mirror (P1)
Observation made with IR Beam Viewer:
The observation of P1 and S3 simultaneously
while locking shows much higher diffusion
64
Thu Oct 3 13:49:58 2019
Loïc Amoudry
Fixed
info
mechanics
Optical room
Pneumatic valves
Frederic and Manu from vacuum group came
this morning to fix again the pneumatic valves
which had a leak again.
65
Thu Oct 3 13:53:44 2019
Loïc Amoudry
Fixed
report
vacuum
Optical room
Cavity under vacuum
The cavity is right now at 6.5e-8 mbar
(turbo pumps on for 1 night and ionic pumps
for 3h), primary pumps and turbo pumps are
66
Thu Oct 3 14:00:13 2019
Loïc Amoudry
Fixed
issue
cabling
Optical room
Electrical trouble (disjunction)
The circuit breaker on ThomX cavity drops
@1.5-1.8kW when we turn on 1/2nd
stage of the amplifier or 3rd stage of the
67
Thu Oct 3 18:00:10 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
ThomX amplifier M2
The ThomX M2 has been measured between
1.5-1.6 for x and y
68
Wed Oct 9 10:08:24 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Improvement holder amplifier fiber
We've added a clamp in the 3rd stage
to prevent the pump fiber from moving and
tilting (it was tilting to the left).
69
Wed Oct 9 10:10:01 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Free Spectral Range (FSR)
FSR is 33.347 MHz @1e-8 mbar
70
Wed Oct 9 10:16:24 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Fiber injection and onefive output power
Fiber injection is finished with the new
ThomX stretching CVBG in double pass (+50%
injection power compared to K-BOX CVBG in
71
Wed Oct 9 11:41:11 2019
Loïc Amoudry
Fixed
info
lasers and optics
Optical room
Onefive spectrum and CVBG spectrum
The Onefive spectrum has shifted a little
bit to lower lambda. It's still enough
for the experiment (3mW injection of ampli
76
Tue Oct 22 09:10:45 2019
Loïc Amoudry
Fixed
report
lasers and optics
Optical room
First mode degeneracy on ThomX
Yesterday, we've observed the first
degeneracy on ThomX cavity at ~115 kW stored.
The shape of the stored power on the oscilloscope
Goto page