24
Mon Oct 4 14:57:04 2021
Aurélien Martens
Fixed
info
detectors and electronics | software
Optical room
ip adress of smaract driver
the ip adress of the smaract driver is
now 10.0.53.10:5000
please think about putting such
25
Mon Oct 4 15:10:17 2021
Aurélien Martens
Fixed
report
mechanics | detectors and electronics | software
Optical room
new position of smaract motors
following the measuremetn at 879.9 MHZ
of the laser theoptical cavity length has
been adjusted to that value from 876MHz setting
26
Mon Oct 4 15:24:14 2021
Aurélien Martens
Fixed
report
lasers and optics | detectors and electronics
Optical room
piezo actuation range
A 10V applied on the laser piezo was found
to induce a frequecny change of about 5kHz,
compatible with expectations from the piezo
27
Mon Oct 4 15:38:43 2021
Aurélien Martens
Fixed
info
detectors and electronics
Optical room
phone is noise
doing the sensitivty measurement of the
piezo we observed satellite peaks around
800 to 900 Mhz. Removing the phones from
28
Tue Oct 5 11:35:16 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
a cavity length measurement gave 880.9Mhz.
The m1/M2 have been put to +5.1000mm both
M3/M4 srill at -2.9mm
29
Tue Oct 5 12:18:34 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
to find the fundamental mode we moved the
cavity mirrors to new positions:
+5.104mm for both planar mirrors
30
Tue Oct 5 12:23:51 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
the M1 is not at 5.1045mm to put the fundamental
on the scanning range of the laser piezo
M2 still at 5.104mm
31
Tue Oct 5 16:23:04 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
after 3hours (1pm --> 4pm) the cavity
moved by 12um in total
new positions: +5.1065mm on M1
43
Thu Dec 2 16:12:17 2021
Aurélien Martens
Fixed
report
mechanics | software
Optical room
new smaract positions
M1 and M2 at 5.1085mm and M3 and M4 at
-2.9mm
Goto page