    Reply   Couplage and CEP, posted by Blanc at Optical room about lasers and optics Fit_Gain_en_fonction_de_la_CEP_Preamp.pngFit_Gain_en_fonction_de_la_CEP_Preamp&Etage1Lockline.png
Pour vérifier la cohérence des mesures précédentes, j'ai fait la même analyse avec l'intensité transmise.

J'ai calculé G = (I_Lock_Trans-I_Delock_Trans)/I_Delock_Refl ainsi que la deviation standard associée, puis moyenné
et fitté, en prenant toujours en compte les barres d'erreurs.
Entry   Verification CEP , posted by Blanc at Optical room about lasers and optics 
On a voulu véifier que le changement de couplage induit par la CEP était une conséquence du changement de CEP dans l'oscillateur
dû au très léger déplacement angulaire de la monture de fond de cavité où il y a le SESAM et le piezo.

Pour cela, j'ai changé très légèrement l'angle vertical de la monture de fond de cavité et j'ai
Entry   Modulation EOM, posted by Blanc at Optical room about lasers and optics osc_preamp_AOM100_etage1_EOM.pngosc_preamp_AOM100_etage1_EOM_etage2.pngosc_preamp_AOM100_EOMbreadboard_matlab.pngosc_preamp_AOM100_EOMbreadboard.png
EOM dans la lockline:

Image 1 (sans 2è étage): on voit la modulation en réflexion de la cavité.

Image 2 (avec 2è étage): on voit la modulation en réflexion de la cavité et il semblerait qu'elle soit présente
Entry   ip adress of smaract driver, posted by Aurélien Martens at Optical room about detectors and electronics | software 
the ip adress of the smaract driver is now 10.0.53.10:5000

please think about putting such kind of changes in the logbook
Entry   new position of smaract motors, posted by Aurélien Martens at Optical room about detectors and electronics | software 
a cavity length measurement gave 880.9Mhz. The m1/M2 have been put to +5.1000mm both M3/M4 srill at -2.9mm
Entry   new position of smaract motors, posted by Aurélien Martens at Optical room about detectors and electronics | software 
to find the fundamental mode we moved the cavity mirrors to new positions:

+5.104mm for both planar mirrors in closed loop

spherical unchanged (-2.9mm)
Entry   new position of smaract motors, posted by Aurélien Martens at Optical room about detectors and electronics | software 
the M1 is not at 5.1045mm to put the fundamental on the scanning range of the laser piezo

M2 still at 5.104mm

M3/M4 at -2.9mm still
Entry   new position of smaract motors, posted by Aurélien Martens at Optical room about detectors and electronics | software 
after 3hours (1pm --> 4pm) the cavity moved by 12um in total

new positions: +5.1065mm on M1 and M2 (5.1050 before)

the drift is 4um/hour which amounts to about 10kHz drift / hour+the temperature of the optics room also changed unfortunaltey (linked to extinction
Entry   phone is noise, posted by Aurélien Martens at Optical room about detectors and electronics 
doing the sensitivty measurement of the piezo we observed satellite peaks around 800 to 900 Mhz. Removing the phones from the experience room(in the
cupboard in the sas) removed that effect immediately.
ELOG V3.1.4-395e101