HOME
SBOX
THOMX
MINICAV
Utilities
MINICAV orders
MINICAV installation
MINICAV commissioning
MINICAV control command
Status of commissioning, report also here plots are reports., Page 2 of 5
Not logged in
Find
|
Login
|
Help
Full
| Summary |
Threaded
89 Entries
Goto page
Previous
1
, 2,
3
,
4
,
5
Next
All
ID
Date
Author
Status
Type
Category
Location
Title
Text
7
Mon Apr 19 19:11:47 2021
Manar Amer
Fixed
report
mechanics | software
Other
Distances between mirrors
At the reference zero the
distance between the mirrors is (taken from
a reference presentation "status9nov2020"
8
Tue Apr 27 13:57:15 2021
Manar Amer
Fixed
report
lasers and optics
Other
Alignment using Koheras
Following the Helium Neon Alignment + change
in the distance between the mirrors to be;
M3-M4 = 90.5 mm , M1-M2 = 80.2 mm -→
6x
9
Thu Apr 29 06:14:09 2021
Manar Amer
Fixed
report
lasers and optics
Other
Mode observed and cavity Lock
** Following up from yesterday an observation
about the TM00 mode : it has been seen with
similar dimensions and its position is the
10
Fri Apr 30 17:41:10 2021
Aurélien Martens
Fixed
report
lasers and optics | detectors and electronics
Optical room
Lock, cavity length and finesse estimate
Ronic just suceeded in obtaining a reasonably
good lock on the cavity. Air flow is switched
off.
11
Tue May 4 15:56:33 2021
Manar Amer
Fixed
report
mechanics | lasers and optics | software
Other
Distances between mirrors
New update on the position of the Motors
for the cavity
***** we moved
12
Fri May 7 15:40:10 2021
Ronic Chiche
Fixed
info
lasers and optics
Optical room
Theoretical Finesse, Gain and Coupling
For spherical mirrors M3 and M4 (batch
C117I054) the reflectance (R) is around 99.9987%
(if T+R=1 => T=13ppm)
14
Wed Jun 30 20:29:17 2021
Manar Amer
Fixed
report
lasers and optics
Other
Mode observed and cavity Lock
New configuration is made. The new mode
observed in NF_Trans is the following :
16
Tue Sep 7 11:05:47 2021
Aurélien Martens
Fixed
report
lasers and optics | detectors and electronics
Optical room
Lock, cavity length and finesse estimate
we observed that the transmitted light
coming from the cavity is made of the cavity
mode light and the scattered light on the
17
Tue Sep 7 14:27:07 2021
Blanc
Fixed
info
lasers and optics
Optical room
Polarisation Results of the NKT
I made many tests about polarization and
we can see some points thanks to the following
figures :
18
Tue Sep 7 17:48:50 2021
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
Locking of the cavity and setup changing
We change the setup a bit to have the same
polarization on the photodiode and the PDH
(in reflexion of the cavity). CF: schematics
19
Wed Sep 8 10:50:38 2021
Blanc
Fixed
info
lasers and optics
Optical room
Polarisation Results of the NKT
To have the polarisation, we must have
1 value because the laser in entry of the
system has 1 polar. Due to that, the graphe
20
Thu Sep 9 16:34:37 2021
Blanc
Fixed
info
lasers and optics
Optical room
Ring light in the cavity
We put a diaphragm in the input beam but
it doesn't work to suppress the ring
light only but it attenuates the whole transmitted
21
Thu Sep 16 18:23:13 2021
Blanc
Fixed
info
lasers and optics
Optical room
Polarization Results in transmission
After data processing, I finally find the
polarization in transmissin of the FPC. As
you can see below, the polarisation is not
23
Fri Oct 1 16:55:47 2021
Blanc
Fixed
info
mechanics | lasers and optics | detectors and electronics
Optical room
1GHz oscillator Frep measurement
a previous cavity FSR measurement was giving
a center frequency around 867.5MHz.
the
present 1GHz oscillator Frep measurement
24
Mon Oct 4 14:57:04 2021
Aurélien Martens
Fixed
info
detectors and electronics | software
Optical room
ip adress of smaract driver
the ip adress of the smaract driver is
now 10.0.53.10:5000
please think about putting such
25
Mon Oct 4 15:10:17 2021
Aurélien Martens
Fixed
report
mechanics | detectors and electronics | software
Optical room
new position of smaract motors
following the measuremetn at 879.9 MHZ
of the laser theoptical cavity length has
been adjusted to that value from 876MHz setting
26
Mon Oct 4 15:24:14 2021
Aurélien Martens
Fixed
report
lasers and optics | detectors and electronics
Optical room
piezo actuation range
A 10V applied on the laser piezo was found
to induce a frequecny change of about 5kHz,
compatible with expectations from the piezo
27
Mon Oct 4 15:38:43 2021
Aurélien Martens
Fixed
info
detectors and electronics
Optical room
phone is noise
doing the sensitivty measurement of the
piezo we observed satellite peaks around
800 to 900 Mhz. Removing the phones from
28
Tue Oct 5 11:35:16 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
a cavity length measurement gave 880.9Mhz.
The m1/M2 have been put to +5.1000mm both
M3/M4 srill at -2.9mm
29
Tue Oct 5 12:18:34 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
to find the fundamental mode we moved the
cavity mirrors to new positions:
+5.104mm for both planar mirrors