18
Tue Sep 7 17:48:50 2021
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
Locking of the cavity and setup changing
We change the setup a bit to have the same
polarization on the photodiode and the PDH
(in reflexion of the cavity). CF: schematics
19
Wed Sep 8 10:50:38 2021
Blanc
Fixed
info
lasers and optics
Optical room
Polarisation Results of the NKT
To have the polarisation, we must have
1 value because the laser in entry of the
system has 1 polar. Due to that, the graphe
20
Thu Sep 9 16:34:37 2021
Blanc
Fixed
info
lasers and optics
Optical room
Ring light in the cavity
We put a diaphragm in the input beam but
it doesn't work to suppress the ring
light only but it attenuates the whole transmitted
21
Thu Sep 16 18:23:13 2021
Blanc
Fixed
info
lasers and optics
Optical room
Polarization Results in transmission
After data processing, I finally find the
polarization in transmissin of the FPC. As
you can see below, the polarisation is not
22
Fri Sep 24 09:55:35 2021
Manar Amer
Under Process
report
lasers and optics
Optical room
Reflection Line Polarization Measuremet
With the help of Ronic the cavity was locked
in preparation to measure the polarization
of the reflection line when the cavity is
23
Fri Oct 1 16:55:47 2021
Blanc
Fixed
info
mechanics | lasers and optics | detectors and electronics
Optical room
1GHz oscillator Frep measurement
a previous cavity FSR measurement was giving
a center frequency around 867.5MHz.
the
present 1GHz oscillator Frep measurement
24
Mon Oct 4 14:57:04 2021
Aurélien Martens
Fixed
info
detectors and electronics | software
Optical room
ip adress of smaract driver
the ip adress of the smaract driver is
now 10.0.53.10:5000
please think about putting such
25
Mon Oct 4 15:10:17 2021
Aurélien Martens
Fixed
report
mechanics | detectors and electronics | software
Optical room
new position of smaract motors
following the measuremetn at 879.9 MHZ
of the laser theoptical cavity length has
been adjusted to that value from 876MHz setting
26
Mon Oct 4 15:24:14 2021
Aurélien Martens
Fixed
report
lasers and optics | detectors and electronics
Optical room
piezo actuation range
A 10V applied on the laser piezo was found
to induce a frequecny change of about 5kHz,
compatible with expectations from the piezo
27
Mon Oct 4 15:38:43 2021
Aurélien Martens
Fixed
info
detectors and electronics
Optical room
phone is noise
doing the sensitivty measurement of the
piezo we observed satellite peaks around
800 to 900 Mhz. Removing the phones from
28
Tue Oct 5 11:35:16 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
a cavity length measurement gave 880.9Mhz.
The m1/M2 have been put to +5.1000mm both
M3/M4 srill at -2.9mm
29
Tue Oct 5 12:18:34 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
to find the fundamental mode we moved the
cavity mirrors to new positions:
+5.104mm for both planar mirrors
30
Tue Oct 5 12:23:51 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
the M1 is not at 5.1045mm to put the fundamental
on the scanning range of the laser piezo
M2 still at 5.104mm
31
Tue Oct 5 16:23:04 2021
Aurélien Martens
Fixed
report
detectors and electronics | software
Optical room
new position of smaract motors
after 3hours (1pm --> 4pm) the cavity
moved by 12um in total
new positions: +5.1065mm on M1
32
Tue Oct 5 18:24:53 2021
Ronic Chiche
Fixed
info
lasers and optics
Optical room
Locking with fast analog loop on AOM
in addition to the standard locking scheme
with the GHz laser PZT,
we added an AOM after the PDH modulation
33
Thu Oct 7 17:53:53 2021
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
Finess and coupling measurement
We did the measurement of the Finess and
coupling with the NKT, with 2 EOM, without
AOM (so the lock signal is noisy), on the
34
Fri Oct 8 16:02:19 2021
Blanc
Fixed
info
lasers and optics | detectors and electronics
Optical room
Setup and measurements
To summerize the results of this week :
We made the setup in attachement
5 and align it to have the good mode in the
35
Tue Oct 19 18:27:20 2021
Ronic Chiche
Fixed
report
mechanics | lasers and optics | detectors and electronics
Optical room
PZT resonant frequencies
we have excited the PZT with a swept sinus
wave from 1kHz to 10kHz and from 10kHz to
100kHz.
36
Wed Oct 20 12:36:15 2021
Ronic Chiche
Fixed
report
lasers and optics
Optical room
Amplitude GHz oscillator phase noise with PZT effect
3 phase noise measurements made on the
Amplitude GHz oscillator with different PZT
configurations :
37
Wed Oct 20 14:54:00 2021
Ronic Chiche
Fixed
info
lasers and optics | detectors and electronics
Optical room
Phase noise measurement of the Amplitude MIKAN
MIKAN phase noise and RIN measurements: