HOME
Prise de donnees
MML
Controle commande
Simulations
Notes
Hardware
Ligne X
Laser Interaction
Diagnostiques
Synchronisation
Synchronisation
Elog synchro, Page 1 of 7
Not logged in
Find
|
Last day
|
Login
|
Help
Full
| Summary |
Threaded
138 Entries
Goto page 1,
2
,
3
...
5
,
6
,
7
Next
All
ID
Date
Author
Status
Type
Category
Important
Subject
Icon
Text
18
Tue Oct 19 12:48:42 2021
Entered by vincent.chaumat from 134.158.88.158 on Tue Oct 19 12:48:20 2021
Under Process
Question
Timing
DG3 (diag) output frequency
Suite des investigation avec François
W ce matin:
Les codes "fréquence"
30
Fri Jan 14 10:44:21 2022
Entered by Super Team from 134.158.195.141 on Fri Jan 14 10:44:08 2022
Under Process
Question
Timing
Démarrage des DS des générateurs de retard
Pour redémarrer le DS Sim.SY/DEG.sim
:
/data/shared/DS_CALC/launch_ds_gene_retard.sh
31
Fri Jan 14 11:05:12 2022
Entered by Super Team from 134.158.195.141 on Fri Jan 14 10:44:08 2022
Fixed
Question
Timing
RE: Démarrage des DS des générateurs de retard
MAUVAIS REPERTOIR !!!
Pour lancher les 2 DS il faut faire
:
16
Thu Oct 14 08:50:36 2021
Entered by vincent.chaumat from 134.158.88.158 on Thu Oct 14 08:50:15 2021
Problem
Timing
Re start synchro et défaut fonctionnement IHM synchro
La synchro est en route (le synthé
3GHz) avait été arreté
et redémarré mais avec des
17
Mon Oct 18 14:37:15 2021
Entered by Alexandre Moutardier from 134.158.195.144 on Mon Oct 18 14:36:58 2021
Not Fixed
Problem
Timing
pB taux de répétition machine
pB de taux de répétition
des signaux de déclenche:
Dans l'IHM le taux de répétition
19
Tue Oct 19 14:13:15 2021
Entered by vincent.chaumat from 134.158.195.144 on Tue Oct 19 14:12:56 2021
Fixed
Problem
Timing
frequence DG3
La fréquence des signaux de déclenches
du DG3 (diag ) est conforme à celle
de l'IHM en salle de controle:
23
Tue Nov 2 16:19:42 2021
Entered by vincent.chaumat from 134.158.195.144 on Tue Nov 2 16:19:18 2021
Not Fixed
Problem
Timing
DEG1 50Hz
NNous avons un pB qsur le DEG1 en salle
de controle:
bien que ce soit la fréquence
24
Wed Nov 3 08:08:21 2021
Entered by vincent.chaumat from 134.158.88.158 on Wed Nov 3 08:00:30 2021
Not Fixed
Problem
Timing
Carte synchro CPLD, entered from 134.158.88.158
La carte synchro CPLD du chassis synchro
a les sorties DEG 2 3 4 qui se décale
par rapport à la sortie DEG1 (50 Hz)
29
Tue Jan 4 15:26:52 2022
Entered by Nicolas Delerue from 80.119.21.73 on Tue Jan 4 15:26:37 2022
Fixed
Problem
Timing
Tous les DEG avaient été réinitialisés...
Tous les DEG avaient été
remis à zéro... Peut-être
qu'une interface synchro était
34
Fri Feb 11 11:29:48 2022
Entered by SC/HM/VS from 134.158.195.141 on Fri Feb 11 11:10:04 2022
Under Process
Problem
Other
DS miroirs lasers M4 et M5
Impossible d'accéder au DS des
miroirs M4 et M5 du laser.
Impossible d'aligner le laser
38
Mon Mar 7 14:49:27 2022
Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022
Under Process
Problem
Material
Probleme ecran Synthe linac
L 'ecran du synthe linac ne fonctionne
plus.
Il est possible de se connecter
39
Mon Mar 7 14:54:58 2022
Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022
Under Process
Problem
Material
RE: Probleme ecran Synthe linac
40
Mon Mar 7 15:24:48 2022
Entered by Nicolas Delerue from 134.158.195.144 on Mon Mar 7 14:49:13 2022
Under Process
Problem
Material
RE: RE: Probleme ecran Synthe linac
*RST
SOUR:POW:POW?
-30
48
Tue Jun 13 13:00:27 2023
Entered by Nicolas Delerue from 134.158.88.175 on Tue Jun 13 13:00:12 2023
Under Process
Problem
Other
Pb insertion dephaseur
L'insertion des déphaseurs 500MHz
a causé du bruit sur le signal envoyé
à la cavité RF. Cf copies d'eçran
71
Thu Nov 9 13:55:58 2023
KD
Under Process
Problem
Material
puissance 500MHz RI
Aujourd'hui la puissance envoyé
par le synthé 500MHz RI était
trop faible (-15dbm au niveau de l'ampli
84
Tue Mar 5 13:07:34 2024
Entered by Vincent Chaumat from 134.158.76.115 on Tue Mar 5 13:07:18 2024
Not Fixed
Problem
Timing
Changement de fréquence anneau => pB synchro
Apres le changement de longueur de l'anneau:
la freequence 500Ri est de 500.07MHz
=> 33Ri = 33.338MHz
85
Tue Mar 5 15:43:19 2024
Entered by Nicolas Delerue from 80.119.21.73 on Tue Mar 5 15:43:05 2024
Under Process
Problem
Material
Synthetizer anneau planté
Le synthetizer de l'anneau ne réponds
plus aux commandes à distances.
Une intervention en local semble
86
Tue Mar 5 16:31:25 2024
VC
Fixed
Problem
Timing
Synthé anneau baie 9
Pb résolu: il fallait etaindre et
redémarrer le synthé (le cable
réseau avait été débranché
Draft
Tue May 28 08:33:42 2024
M EK
Under Process
Problem
Other
Conditionnement section 28/05
109
Wed Feb 19 13:59:26 2025
Entered by Nicolas Delerue from 80.119.21.73 on Wed Feb 19 13:59:11 2025
Problem
Timing
Problème avec le DS SIM/SY/DEG.sim
Il y a un problème avec le DS SIM/SY/DEG.sim
qui stock des valeurs entières au
lieu de valeures décimales.
Goto page 1,
2
,
3
...
5
,
6
,
7
Next
All
ELOG V3.1.4-395e101