HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Hardware
  Notes sur les differents appareils (Klystron, Etuves, Sondes Etuve, Temperature, Modulateur,...), Page 2 of 2  Not logged in ThomX    logo
ID Date Author Statusdown Type Category Important Subject Icon
  2   Thu Jun 6 11:53:24 2019 nfalcoz QuestionDocs , entered from 134.158.195.143 
Coucou Test
  3   Thu Jun 6 11:54:08 2019 nfalcoz QuestionDocs , entered from 134.158.195.143 
Coucou Test
  4   Thu Jun 6 12:00:33 2019 nfalcoz QuestionDocs , entered from 134.158.195.143 
Coucou Test2
  Draft   Tue Jun 11 12:25:21 2019 Entered by Falcoz Nicolas from 134.158.195.143 on Tue Jun 11 11:55:34 2019      
  6   Wed Jun 12 11:04:46 2019 nfalcoz InfoDocs , entered from 134.158.195.143 
Essai 1 sans piece jointe
  7   Wed Jun 12 11:09:26 2019 nfalcoz ProblemSondes Etuve , entered from 134.158.195.143 
Essai 2 sans pièe jointe
  8   Wed Jun 12 11:24:05 2019 nfalcoz ProblemSondes Etuve , entered from 134.158.195.143 
/self.saisieTexte.toPlainText()
  9   Wed Jun 12 11:45:26 2019 nfalcoz UrgentTemperature , entered from 134.158.195.143 
Essai 3 sans pièce jointe (-_/!?éèêü)
  10   Wed Jun 12 14:15:20 2019 Entered by Falcoz Nicolas from 134.158.195.143 on Wed Jun 12 14:15:07 2019 ProblemEtuves Test accent éè 

Test accent éè

  11   Wed Jun 12 14:23:38 2019 nfalcoz ProblemTemperature , entered from 134.158.195.143 
éééééèèè
  12   Fri Jun 14 13:55:33 2019 nfalcoz FixSondes Etuve , entered from 134.158.195.143 
Test 3 screens
  13   Thu Jun 27 14:26:55 2019 nfalcoz FixKlystron , entered from 134.158.195.143 
Test IHMLogBook
  14   Thu Jul 11 11:14:46 2019 nfalcoz OtherDocs , entered from 134.158.195.143 
Test
  23   Tue Nov 16 14:39:32 2021 Entered by Hayg Guler from 134.158.195.141 on Tue Nov 16 14:39:17 2021 LinacRF D1 Calibrations et réglages Canon (Pierre, Nourredine) 
klystron à 1090        
att (dB) Pic (MW) au wattmètre Pic cristal (MW) % erreur Gradient (MV/m)
2 3.9 4.12 6 69
1.75 4.1 4.39 7 71
1.5 4.35 4.66 7 73
1.25 4.6 4.92 7 75
1 5 5.2 4 79
0.75 5.3 5.58 5 81
0.5 5.6 5.92 6 83
0.25 6.1 6.27 3 87
0 6.6 6.64 1 91
  24   Mon Jan 10 16:43:42 2022 Entered by Viktor Soskov from 134.158.195.153 on Mon Jan 10 16:43:10 2022 InfoLaser Cours d'eau sur le laser -cathode 

Cours d'eau a passé à travers du gril de la climatisation (en toit de la salle laser ) et tombé sur le laser et la table optique!!!!

  28   Fri Jun 17 10:53:58 2022 Entered by Super Team from 134.158.195.141 on Fri Jun 17 10:53:43 2022 Info | LinacRF D1 Moteurs Atténuateur déphaseurs -> Vélocité 

Vélocité modifiée au niveau des Ds :

li/hfi/dep.01-mot.01 : 25 step/s --> 80
li/hfi/att.01-mot.01  : 5 step/s --> 50
li/hfi/att.01-mot.02 : 5 step/s --> 50

 

 

  31   Fri Sep 13 17:11:13 2024 KD InfoDiag | RF D1 | Electronique réflechis canon 

remplacement attenuation sur le signal réflechi canon par un 6.1dB

3dB --> 6.1dB

ELOG V3.1.4-395e101