HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Hardware
  Notes sur les differents appareils (Klystron, Etuves, Sondes Etuve, Temperature, Modulateur,...), Page 2 of 2  Not logged in ThomX    logo
ID Date Author Status Type Category Important Subjectdown Icon
  23   Tue Nov 16 14:39:32 2021 Entered by Hayg Guler from 134.158.195.141 on Tue Nov 16 14:39:17 2021 LinacRF D1 Calibrations et réglages Canon (Pierre, Nourredine) 
klystron à 1090        
att (dB) Pic (MW) au wattmètre Pic cristal (MW) % erreur Gradient (MV/m)
2 3.9 4.12 6 69
1.75 4.1 4.39 7 71
1.5 4.35 4.66 7 73
1.25 4.6 4.92 7 75
1 5 5.2 4 79
0.75 5.3 5.58 5 81
0.5 5.6 5.92 6 83
0.25 6.1 6.27 3 87
0 6.6 6.64 1 91
  19   Tue Oct 12 12:07:22 2021 Entered by Viktor Soskov from 134.158.195.153 on Tue Oct 12 12:06:17 2021FixedInfo | LinacLaser Attenuator_11_10_201 

mesures faites avec 180 uJ et Iris entièrement ouverte. Puissance mesurée au niveau du shutter (après atténuateur)

  32   Mon May 12 16:27:53 2025 Entered by Viktor Soskov from 134.158.195.153 on Mon May 12 16:27:34 2025FixedLinacLaser Attenuator-Energy 

Bonjour, voici la courbe l'energie UV sur la cathode vs la position d'attenuateur pour l'iris=1.3mm (l'energie MAX=25mkJ). Les courbes sont identiques pour tous les diametres d'iris sauf les energies MAX sont differents:

d=1.3mm  Emax=25mkJ  ; d=2mm Emax=50mkJ  ;  d=3mm Emax=73mkJ ;   d=4mm Emax=88mkJ ; d=5mm Emax=97mkJ  (les energies MAX actuelles)

Viktor

  33   Tue Jun 3 17:00:58 2025 Entered by Viktor Soskov from 134.158.195.153 on Tue Jun 3 17:00:35 2025FixedInfoLaser Attenuator Energy 
  1   Thu Jun 6 10:58:43 2019 Miwiwi QuestionDocs , entered from 134.158.195.143 
coucou loulou
  2   Thu Jun 6 11:53:24 2019 nfalcoz QuestionDocs , entered from 134.158.195.143 
Coucou Test
  3   Thu Jun 6 11:54:08 2019 nfalcoz QuestionDocs , entered from 134.158.195.143 
Coucou Test
  4   Thu Jun 6 12:00:33 2019 nfalcoz QuestionDocs , entered from 134.158.195.143 
Coucou Test2
  6   Wed Jun 12 11:04:46 2019 nfalcoz InfoDocs , entered from 134.158.195.143 
Essai 1 sans piece jointe
  7   Wed Jun 12 11:09:26 2019 nfalcoz ProblemSondes Etuve , entered from 134.158.195.143 
Essai 2 sans pièe jointe
  8   Wed Jun 12 11:24:05 2019 nfalcoz ProblemSondes Etuve , entered from 134.158.195.143 
/self.saisieTexte.toPlainText()
  9   Wed Jun 12 11:45:26 2019 nfalcoz UrgentTemperature , entered from 134.158.195.143 
Essai 3 sans pièce jointe (-_/!?éèêü)
  11   Wed Jun 12 14:23:38 2019 nfalcoz ProblemTemperature , entered from 134.158.195.143 
éééééèèè
  12   Fri Jun 14 13:55:33 2019 nfalcoz FixSondes Etuve , entered from 134.158.195.143 
Test 3 screens
  13   Thu Jun 27 14:26:55 2019 nfalcoz FixKlystron , entered from 134.158.195.143 
Test IHMLogBook
  14   Thu Jul 11 11:14:46 2019 nfalcoz OtherDocs , entered from 134.158.195.143 
Test
  Draft   Tue Jun 11 12:25:21 2019 Entered by Falcoz Nicolas from 134.158.195.143 on Tue Jun 11 11:55:34 2019      
ELOG V3.1.4-395e101