Entry   Entered by Nicolas Delerue from 134.158.88.175 on Thu Oct 9 16:55:01 2025; Verification de la calibration BPM 2025-10-09_BPM_transmission.png

Verification de la transmission sur les BPMs.

Entry   Entered by Nicolas Delerue from 134.158.88.175 on Thu Oct 9 16:55:01 2025; Verification de la calibration BPM 
 
Entry   Entered by Super Team from 134.158.195.142 on Thu Oct 9 12:06:48 2025; problème DS libera HS Screenshot_2025-10-09_12-06-03_BPM_error.png

Les DS du libéra 2 sont HS. Des modifications ont été apporté qui font planté l'init des DS.

 

    Reply   Entered by Super Team from 134.158.195.142 on Thu Oct 9 12:06:48 2025; RE: problème DS libera HS 

Après appel avec Nicolas, nous avons redémarré, ça a résolu le probleme.

Entered by Super Team from 134.158.195.142 on Thu Oct 9 12:06:48 2025 wrote:

Les DS du libéra 2 sont HS. Des modifications ont été apporté qui font planté l'init des DS.

 

 

Entry   ND; Mise en securité BPM, RDP, WAC et SST avant coupure électrique 

Les liberas, red-pitaya (diags), wavecatcher et cameras ont été eteints en prévision de la coupure électrique de demain.

 

    Reply   ND; RE: Mise en securité BPM, RDP, WAC et SST avant coupure électrique 

Redémarrage effectué.

ND wrote:

Les liberas, red-pitaya (diags), wavecatcher et cameras ont été eteints en prévision de la coupure électrique de demain.

 

 

Entry   VC,ND; Probleme WAC1 resolu... Screenshot_from_2025-09-01_16-47-00.png

Le WAC1 est reparé...

Peut-être que le problème venait des valeurs de synchronisation chargées précédemment.

Entry   Entered by Nicolas Delerue from 80.119.21.73 on Mon May 19 23:30:58 2025; Problème déclenchement wavecatcher 20250519_174623.jpg20250519_175234.jpg

Afin de résoudre le problème de double déclenche des wavecatcher on augmente la longueur de l'impulsion.

Test avec seulement le kicker d'injection allumé (septum en FAULT).

Avant modification on voit une double impulsion toutes les ~5 secondes.

Après modification on voit que c'est la longueur de l'impulsion qui varie...

Est-ce que le bruit créé par le kicker réinitialise un compteur pour certaines voie du générateur de retard?

=> Cela devrait résoudre le problène mais à vérifier.

Test à faire: 

- regarder si le problème change selon que la porte arrière de la baie synchro est ouverte ou fermée (si c'est de la CEM on devrait avoir un effet)

 

Entry   Sc, ND; SR in ring alignement viewer_2025_02_13_09_19.png

Laser aligned on MRSV.
 

 

 

 

Entry   IC, VM, VK, ND; MRSV studies 6x

Beam position observed on the MRSV when changing RI-C1/STR.06-H01 (3 images) and then RI-C1/STR.06-V01 (3 images).

We can see that the beam moves horizontally with the steerer. It is not so clear in the vertical plane.

 

Entry   Entered by Nicolas Delerue from 134.158.195.144 on Fri Nov 15 11:48:36 2024; BPM transmission GUI Screenshot_from_2024-11-15_12-03-43.png

A GUI to measure the transmission through the BPMs has been developped. It is in the git panneaux at Diags/BPM (a git pull is needed to have access to it).

To lauch it type:

ipython IHM_BPM_ratio.py

You get a window with the interface like in the attached image.

For the measurements to be meaningfull you need to click on "set fixed gain". It will set all the BPms on teh same fixed gain.

Once you are done, it is preferable to revert the BPMs to auto gain by clicking on "set auto gain".

Note: The charge on TL/BPM.03 is higher than on TL/BPM.02 see separate elog entry about this.

Entry   Entered by Nicolas Delerue from 134.158.196.122 on Tue Oct 22 11:32:11 2024; MRSV is aligned 

A preliminary alignment of the MRSV has been done this morning.

There were difficulties with the camera, that have been adressed but only at slow rate.

To be tried on Friday.

 

Entry   Entered by Nicolas Delerue from 134.158.195.142 on Fri Sep 6 13:42:59 2024; Etude declencemenent Basler ACE 

J'ai regarde le probleme des camera basler ACE avec Pylon.

Il semeblerait que la camera ait une latence de 650us.

Je n'ai pas trouve de reglage permetant de resoudre le probleme.

Entry   Entered by Nicolas Delerue from 193.55.29.171 on Thu Sep 5 16:20:08 2024; Ajustement résolution LI/DG/SST.01 

La résolution de LI/DG/SST.01 a été ajustée. L'accès à la station est rendue difficile par les modifications faites à la station.

Entry   ND; Retard TL/DG/SST.02 

Retard TL/DG/SST.02 passe de 96ms a 6ms.

Entry   IC, ND,VK; Test profondeur memoire BPMs 

Test de la profondeur memoire des libera.

Il est possible de mettre 'TbtLength' a 200000 a 1Hz sur  'RI-C1/DG/BPM.01-LIB.03'.

Si l'on tente d'ecrire 200001 sur 'TbtLength', il y a une erreur.

Si l'on met 'TbtLength' a plus de 480000 a 10Hz sur les 12 BPMs de l'anneau il y a un timeout.

Si l'on met 'TbtLength' a 200000 a 1Hz sur les 12 BPMs de l'anneau il n'y a pas de timeout.
Si l'on met 'TbtLength' a 200000 a 5Hz sur les 12 BPMs de l'anneau il n'y a pas de timeout.
Si l'on passe a 10Hz avec 'TbtLength' a 200000 crash de 'RI-C1/DG/BPM.01-LIB.03'.

Si l'on met 'TbtLength' a 10000 a 10Hz sur 8 BPMs de l'anneau et 200000 sur  'RI-C1/DG/BPM.01-LIB.03',  'RI-C1/DG/BPM.05-LIB.04', 'RI-C2/DG/BPM.03-LIB.05' il n'y a pas de timeout mais comportement bizarre.

Recomendation: for operation with  'TbtLength'=200000 turns  , one should trigger the diags at 1 Hz, otherwise libera crashes and has to be restarted.

 

 

Entry   Entered by Nicolas Delerue from 134.158.195.142 on Mon Feb 5 14:44:15 2024; En cas d'extinction des SST 

Si l 'on ne parvient pas a changer le temps d'exposition des CCD dans l 'ancienne interface, sur PlateformeIHM choisir "SST laucnher" puis dans la colonne controls du SST Laucnher, choisir la SST  

icon1.gif   ND; Cable LED camera EL 

Le cable de controle de la LED de EL/DG/SST.03 est le 36041. Il a été branché sur le switch controlé sortie 3.

Entry   Entered by Nicolas Delerue from 80.119.21.73 on Wed Jan 17 01:44:26 2024; WAC remis en déclenchement externe 

ER/CA/RAC.05-WAC.02 était en déclenchement interne avec déclenchement sur ch0 alors qu'il avait été configuré en déclenchement externe jeudi dernier. Je l'ai remis en déclenchement externe et j'ai retiré le déclenchement sur ch0.

Entry   Entered by Nicolas Delerue from 134.158.88.175 on Tue Jan 16 11:00:08 2024; Automatic gain sur BPM 

Le gain automatique sur les BPMs avait été désactivé. Il a été réactivé pour LI-TL-LE.

 

Entry   ND; Redémarrage diagnostics 
 
Entry   Marie Labat, ND; Tests camera a balayage 

Des mesures ont ete faites sur la camera a balayage a differentes frequence.

Le probleme a ete identifie (un composant que l'on pensait etre un dephaseur etait en fait un diviseur de frequence).

Apres rectification des branchements la camera fonctionne bien.

Mesures a continuer en faisceau.

 