HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Diagnostiques
  elog des diags.  Not logged in ThomX    logo
Message ID: 42     Entry time: Mon Nov 8 14:49:43 2021
 Author: Nicolas Delerue, Alexandre MOUTARDIER, Pierre GUILLON, Rasha ABUKESHEK & Ruth ILLICACHI 
 Status:  
 Type: Info 
 Category: Cameras SST 
 Important:
 Subject: Setting of the cameras 
 Icon:  

Working on LI/SST.1:

We looked at the YAG:Ce signal as function of time.

From the Bassler camera manual, the scout scA640 have a latency of 33.80us and a minimum exposure time of 24us.

We scanned the camera delay to see the YAG signal to see the fast decay and the slow decay.

We attempted to see the OTR signal but the charge was too low. A scan of charge vs the phase gave a maximum charge of 12pC.

 

ELOG V3.1.4-395e101