| ID |
Date |
Author |
Status |
Type |
Category |
Important |
Subject |
Icon |
Text |
 |
|
217
|
Tue Dec 14 09:45:43 2021 |
Entered by Nicolas Delerue from 80.119.21.73 on Mon Dec 13 17:53:57 2021 | Not Fixed | Problem | CC |
|
RE: RE: RE: RE: RE: RE: RE: Clients3 est en panne... | | Cette entrée n'est pas dans
la bonne catégorie, elle devrait être
dans '"pannes". |
|
|
221
|
Thu Dec 16 10:40:03 2021 |
Entered by Moutardier Alexandre from 91.168.92.148 on Thu Dec 16 10:39:49 2021 | | Info | CC |
|
test en ssh | | Connection ssh sur client4 pour tester
une modification de health_check |
|
|
222
|
Thu Dec 16 14:57:31 2021 |
Entered by Moutardier Alexandre from 91.168.92.148 on Thu Dec 16 10:39:49 2021 | | Info | CC |
|
RE: test en ssh | | Modifications faites, testées et
fonctionnelles.
|
|
|
369
|
Wed Feb 23 12:45:44 2022 |
Entered by Christelle Bruni from 134.158.195.142 on Wed Feb 23 12:45:28 2022 | | Problem | CC |
|
Impossible de redémarrer srv3 , intervention du contr^ole commande necessaire | | Laser passé en gate_in false en
attendant
Olivier est venu nous dépanner, |
|
|
377
|
Tue Mar 1 10:34:30 2022 |
Entered by Super Team from 134.158.195.141 on Tue Mar 1 10:34:10 2022 | Not Fixed | Urgent | CC |
|
panneau IHM ne se lance pas [resolu] | | resolu
Voici l'erreur, |
|
|
718
|
Thu Mar 23 15:15:56 2023 |
SC | Under Process | Problem | CC |
|
Tests CC apres re-démarrage | | 15h16 redémarrage de client 3
Problème avec le commutateur
de la baie en salle de controle (celui qui |
|
|
719
|
Fri Mar 24 08:52:49 2023 |
SC/JNC/VC | Under Process | Problem | CC |
|
Redémarrage ThomX | | 8h53 Serveur DNS et DHCP non redémarré,
ping ne fonctionne pas, en attente d'une
solution |
    |
|
991
|
Thu Jan 9 10:31:11 2025 |
Entered by Nicolas Delerue from 134.158.195.144 on Thu Jan 9 10:30:34 2025 | Not Fixed | Problem | CC |
|
DS ThomX_PhotoCathode using a lot of CPU | | The load on client5 is 29 making all operations
slow.
Appently the DS ThomX_PhotoCathode |
 |
|
91
|
Tue Oct 5 10:55:40 2021 |
Entered by Hayg Guler from 134.158.195.141 on Tue Oct 5 10:55:25 2021 | Not Fixed | Problem | Aimants | Vide | Linac Commissionning |
|
Interlock RF + Solenoides | |
Gradient accélérateur
: 80 MV/m (atténuateur Canon à
1.5 dB)
Solénoides :
COL1(CC) |
  |
|
315
|
Thu Feb 10 14:31:46 2022 |
Entered by Super Team from 134.158.195.142 on Thu Feb 10 14:31:30 2022 | Under Process | Info | Aimants | RF D1 | MECA | Vide | Linac Commissionning |
|
test AU en salle de controle | | 14h14 : test de l'AU placé en
salle de contrôle :
- armoire electrique dans D1 coupée |
|
|
996
|
Wed Jan 15 08:16:32 2025 |
MJ KD VC HG | Under Process | Shift summary | Aimants | Linac Commissionning | Ring Commissioning |
|
shift du 15 janvier 2025 | | 8h15 : mise en chauffe de la machine à
distance (modulateur, laser, frigo, chiller)
faisceau Linac et TL non déviée |
7x |
|
175
|
Tue Nov 23 10:56:50 2021 |
Entered by Iryna Chaikovska from 134.158.195.143 on Tue Nov 23 10:56:34 2021 | Fixed | Other | Aimants | Linac Commissionning |
|
Cyclage dipole | | For 22/11/2021
There is the remaining field from
the dipoles in the TL. In order to go straight |
  |
|
177
|
Tue Nov 23 13:12:37 2021 |
Entered by Iryna Chaikovska from 134.158.89.93 on Tue Nov 23 13:12:22 2021 | Under Process | Other | Aimants | Linac Commissionning |
|
Cyclage quadrupoles | | 23/11/2021
We would like to cycle the quadrupoles
in the linac. The procedure of the cycling |
    |
|
223
|
Thu Dec 16 14:58:50 2021 |
Entered by Moutardier Alexandre from 91.168.92.148 on Thu Dec 16 14:58:26 2021 | | Problem | Aimants | Linac Commissionning |
|
Alimentation en état FAULT !!! | | D'après health_check toutes
les alimentations electrique des solenoides,
deviateur et quadrupole sont en état |
|
|
197
|
Thu Dec 2 10:38:44 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Thu Dec 2 10:38:07 2021 | | Anneau | Aimants |
|
intervention Soleil | | Bonjour, Patrick Alexandre et Didier Muller
( Soleil ) viendrons demain Vendredi 03/12
toute l'après midi, j'aurai |
|
|
200
|
Mon Dec 6 11:30:53 2021 |
Entered by Maher OMEICH from 134.158.91.212 on Mon Dec 6 11:30:27 2021 | Under Process | Anneau | Aimants |
|
Tests EPs | | Bonjour, demain mardi 07/12 sera une journée
casemate ouverte pour les tests des éléments
pulsées ( kikers .... ) |
|
|
249
|
Fri Jan 14 11:08:37 2022 |
Entered by Super Team from 134.158.195.142 on Fri Jan 14 11:08:25 2022 | Fixed | Linac | Aimants |
|
Alimentation solenoïdes | | Les DSs des alimentations des solénoïdes
ont été re-démarré. |
|
|
270
|
Thu Jan 20 16:01:14 2022 |
Emmanuel Goutierre | Fixed | Linac | Aimants |
|
Conversion valeur moteur rotation solénoïde | | Conversion des valeurs des moteurs de rotation
du solénoïde
axmo_z |
|
|
272
|
Thu Jan 20 17:34:19 2022 |
Emmanuel Goutierre | Fixed | Linac | Aimants |
|
RE: Conversion valeur moteur rotation solénoïde | | J'avais fait une entrée e-log
à l'époque où j'ai
configuré les solénïds |
|
|
384
|
Thu Mar 3 12:35:55 2022 |
CB/HG/JNC | Under Process | Linac | Aimants |
|
vérification cablage steerer | | entre le DS et l'alim, OK
il faut vérifier entre l'alim
et le steerer |
|