  951   Thu Oct 31 08:19:25 2024 KDn Dupraz from 109.222.35.58 on Thu Oct 31 08:19:12 2024Under ProcessShift summaryRing Commissioning shift du 31 octobre 2024 

8h15: mise en chauffe en remote (modulateur, laser, chiller, Cycling)

Tuning of the linac and injection to the ring

Goal: Search for the non-dispersive orbit and proper RF frequency

We started from F =500.059 MHz

Frequency change from 500.05 to 500.0853 MHz

We stopped at 500.0853 MHz and proceeded with the orbit correction

3 steereres are at max values. Studies continue to understand the other possibilities of corection.

18h Stop ThomX

 

Attachment 1: Screenshot_from_2024-10-31_13-37-11.png
Screenshot_from_2024-10-31_13-37-11.png
Attachment 2: Screenshot_from_2024-10-31_12-07-13.png
Screenshot_from_2024-10-31_12-07-13.png
Attachment 3: closed_orbit_31102024.png
closed_orbit_31102024.png
  1222   Tue Mar 31 15:42:33 2026 KD MJFixedShift summaryLaser | Linac Commissionning | Ring Commissioning shift du 31 mars 2026 : MONO 70 MeV + spectres 61.5 MeV 

/!\ fort impact du moteur Rsample de la ligne X sur la cavité CFP (obligé de le mettre off)

*** Prise mesure Monochromateur ***

* angle initiale mono : Ry_mono(0) = -0.1° (ajouté aux valeurs d'angles pour la position moteur)

* Position fentes initiale [-8;-17]

Point On Axis (problème de référence mono, surement position fentes [-10,-17]), image Pilatus 436 (70keV de threshold) et 439 (30keV de threshold) :

   - Angle Mono 1.33° --> position RSample : 2.92°

   - Angle Mono 1.6° --> position RSample : 3.45°

   - Angle Mono 1.3° --> position RSample : 2.88°

   - Angle Mono 1.23° --> position RSample : 2.73°

H +20mm (position hexapod TX = -13.5):

   - Angle Mono 1.33° --> position RSample : 2.8°

   - Angle Mono 1.6° --> position RSample : 3.3°

H +30mm (position hexapod TX = -24):

   - Angle Mono 1.6° --> position RSample : 3.15°

   - Angle Mono 1.8° --> position RSample : 3.55°

H -20mm (position hexapod TX = 30):

   - Angle Mono 1.23° --> position RSample : 2.95°

   - Angle Mono 1.6° --> position RSample : 3.7°

   - Angle Mono 1.33° --> position RSample : 3.15°

H -30mm (position hexapod TX = 41):

   - Angle Mono 1.33° --> position RSample : 3.25°

   - Angle Mono 1.23° --> position RSample : 3.05°

   - Angle Mono 1.1° --> position RSample : 2.8°

V +20mm (position hexapod TX = 9, TY : 20):

   - Angle Mono 1.33° --> position RSample : 3°

   - Angle Mono 1.6° --> position RSample : 3.55°

   - Angle Mono 1.23° --> position RSample : 2.8°

V -20mm (position hexapod TX = 9, TY : -20):

   - Angle Mono 1.23° --> position RSample : 2.8°

   - Angle Mono 1.6° --> position RSample : 3.55°

   - Angle Mono 1.33° --> position RSample : 3°

 

*** Vers 16h : Passage a 61.5 MeV

Centre faiseau a l'oeil : Fente2 [H , V] = [33 , -18]

Check Dromadaires spectres a V +40 ==> Cf screenshot Dromadaires_61p5_MeV

Vert : Yfpc = - 1.9 mm
Violet            - 1.6    (c'etait la meilleure position pour 50 MeV)
Bleu              - 1.4
Rouge           - 0.8
Noir               - 0.6

On se place a Yfpc = -0.8  car a peu pres correct ... (tres differente du cas 50 MeV)

Re-ouverture des Fente2 pour retrouver le centre faisceau
   ==> Avec Yfpc = -0.8, Plus possible de voir le centre du faisceau dans la config actuelle du Dectris. Cf sceenshot Dectris_centre_faisceau

A suivre demain ...
 

 

Attachment 1: Droma_61p5_MeV_2026-03-31_17-41-07.png
Droma_61p5_MeV_2026-03-31_17-41-07.png
Attachment 2: Dectris_centre_faisceau_2026-03-31_17-19-05.png
Dectris_centre_faisceau_2026-03-31_17-19-05.png
  Draft   Tue Mar 31 07:56:57 2026 KDUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 31 mars 2026 

7h55 : mise en chauffe en remote (frigo/chillers, laser, modulateur, cyclage)

==> vérifier la pression SF6 avant de commencer.  2461mB

HV On

10h05 Laser Phase 29.2269 dg., Sect. Phase 256 dg., Sect. Att. 0.15 dB, I_Gun -107.4324 pC, I_Linac -149.9747 pC, I_TL -133.2527 pC RF_Ampl. 99.1569 kV, RF_Phase -60.51 dg.

15h39 ==> 61.5 MeV, F=500.034945  MHz, Sect Att. 1.00 dB, phase 240. dg.

6h03 Laser Phase 27.2 dg., Sect. Phase 240 dg., Sect. Att. 0.981 dB, I_Gun -110.9555 pC, I_Linac -155.372 pC, I_TL -135.7899 pC RF_Ampl. 99.1184 kV, RF_Phase -47.91 dg.

17h54 ThomX was sopped

 

 

  1130   Tue Sep 30 08:41:41 2025 KDUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 30 septembre 2025 

8h40: mise en chauffe en remote (frigo/chiller, modulateur, laser)

9h30: ajout de graisse sur le verrin du shutter Xline dans la casemate

9h45: le klystron ne passe pas en HV, gros problème de perverance aussi (impossiblde de passer à 1215V)

** Le générateur rigol ne répond plus ==> adresse IP fausse (anciennement celle de camera sst spare) ==> rigol en DHCP nom reseau "dephaseur-sy" = "192.168.229.164"

** Cavité FP instable gros délock ==> impossible de faire le programme de shift.

** Problème de delock visible sur l'accéléromètre ==> travaux devant sciences ACO totalement corrélé avec les délock. 

18h Stop ThomX

  1112   Wed Sep 3 07:47:42 2025 KD VC HG JMUnder ProcessShift summaryLinac Commissionning shift du 3 septembre 2025 

7h47: mise en chauffe en remote (modulateur, frigo/chiller, laser, cyclage)
8H50 demarrage machine
load recette godd_20250821_17_14_40
faisceau ligne dispersive (phase canon 272° phase section 247° DP.01 253.77A image 2025-09-03_09_40_36_tl_dg_sst_02-ccd_01_RAW)
quad scan

10H Moddulateur en standby PPS PA exploi OFF

14h30: Mesures d'émittance à QP3 pour différentes conditions de charge 100pC et 170 pC, fits et scans dans le dossier today
Soucis Iris : Moteur en erreur, valeur 1.35 mm (pas sûre ...)
but des mesures : vérifier le code Matlab (Viktor)
A faire : Xcheck avec le code py (Hayg)
Autre aspect : faire attention aux images saturées, ça change le scan, et donc l"emittance calculée.

17h45 : fin du shift, Kevin va venir voir le shutter.

 

 

 

 

==> il faut réaligner la ligne UV, charge max < 200pC

Attachment 1: 2025-09-03_09_40_36_tl_dg_sst_02-ccd_01_RAW.png
2025-09-03_09_40_36_tl_dg_sst_02-ccd_01_RAW.png
  383   Thu Mar 3 10:56:55 2022 CB/JNC/MOUnder ProcessShift summaryLinac Commissionning shift du 3 mars 

NB : scandinova est présent en observateur

la mesure de la phase ne fonctionne pas, problème de connectique a priori, Viktor regarde A FAIRE il faut changer le cable, fait, ca marche

Image laser sauvée dans laser à 11h00, position H 931, V 589 pixels (conversion .32 um/pixels) --> Ok par rapport à hier

jupyter lancé avec les commandes de l'ID31 de l'elog CC, ca marche

Phase max charge : 238 deg, on reprend légèrement le miroir M4 (départ 390, 5370mm), fin 390, 5373

Phase moins stable qu'hier, cf. trend ci dessous non sensibilité changée 1°3GHz/mV

Charge phase (Att=400mm)

Laser s'est délocké pendant le charge phase, on recommence,

On a perdu le signal photodiode sur l'ihm Rf, Il faut redémarrer les redpitaya A FAIRE fiabiliser la visualisation des signaux

set de paramètres par défaut (trig ext 6, level 0.1, decimination 0) --> fonctionne à nouveau

Positions du laser journée d'hier:

Un battement régulier de 1h30 de période plus sensible en y (vert).

Inversion des cablages pour etre dans la convention

nouvelles config des steerers : LI/STR2H=+0A, LI/STR2V=0A, TL/STR1V=+0A, TL/STRH=+0A, image sauvée à 13h44, le faisceau est en bas de l'écran sans quad. On arrive aps centré dans le premier quad, le BP sortie section indique qu'on est 5 mm en horizontal vers le mur, et -4mm en vertical soit vers le bas

Redémarrage des WaveCatchers , DS et des serveurs associés. La mesure de charge fonctionne.

 

  1051   Thu Apr 3 09:08:03 2025 KDUnder ProcessShift summaryOpt | Linac Commissionning | Ring Commissioning shift du 3 avril 2025 

9h: mise en chauffe machine en remote (Modulateur, frigo/chiller, laser, cyclage aimants).

  Draft   Thu Jun 29 13:09:57 2023 LS, NDNew SolutionShift summaryRing shift du 29 juin 2023 

9:45 Git pull

Test des interfaces... OK

Probleme sur les ecrans du compte operateur ThomX (4x1 ecran) meme apres redemarrage => reconfiguration

10:10 Mise en chauffe

Interlock sur les aimants vu pendant le cyclage. Resolu.

11:30 Faisceau

12:05 Allumage cavite anneau (MEK)

12:15 Perte faisceau...

Apparement le PA avait disjoncte. Intervention MO.

13:00 Retour faisceau

Prise de données TL/FC01

13:30 Transport dans EL, essaie d'amélioration du transport : on a réussi à transporter environ 1/3 de la charge 

Prise de données dans EL/FC01 

15:00 Stockage dans anneau, optimisation 

16:00 Prise de données pour étudier les pertes dans les fibres. 

Prise de données des pertes:

-sans faisceau, avec juste kicker d'injection, septum, ou kicker d'extraction

-sans faisceau, avec tous les EP : obtenir bruit de fond

-avec faisceau, avec juste kicker d'injection, septum, ou kicker d'extraction 

-avec faisceau: prise de données avec différents timing pour le kicker d'extraction => extraire le faisceau pour comprendre le timing de l'acquisition et observer les pertes avec différents timing de d'extraction

  1109   Fri Aug 29 07:48:38 2025 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 29 aout 2025 

7h45: mise en chauffe en remote (modulateur, laser, chiller/frigo, cyclage)

==> problème restant du redémarrage: 

    * redémarrer la synchro

    * problème moteurs

    * autres pas encore vues

  947   Mon Oct 28 18:56:01 2024 KD, HGUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 28 octobre 2024 

17h: faisceau machine.

** On fait un scan de TL/STR1 avec QP1 à QP4 à 0, faisceau aligné (QP1-QP3) coil afin d'avoir un faisceau sur l'écran TL/SST2 "focalisé". 

==> MadX prévoit un couplage de 0.3mm sur Yag pour 1mm de déplacement en entrée dipole, code Matlab prévoit 4.5mm sur Yag pour 1mm de déplacement en entrée dipole

==> la courbe montre position TL/BPM01 (avant dipole) et position sur TL/SST.02 (après dipole)

** On injecte avec recette canon 0dB et recette canon 0.5dB meme performance avec meme paramètres BPM (2E-6 tbtsum pour 0dB et 1.5E-6 pour 0.5dB). 

On mets RiC1/BPM01 et 02 en gain automatique, tbtsum retrouve des niveau "correte" quelques 1E-7. (on désactive le gain auto après)

** on est dans l'anneau avec un "bon stockage" canon 0dB ==> à affiner : recette dans "all_20241028_19_19_52"

 

19h42: arret machine

 

Attachment 1: scan_TL_STR1_VS_TL_YAG2.png
scan_TL_STR1_VS_TL_YAG2.png
Attachment 2: Screenshot_2024-10-28_19-40-50_BPM_ring.png
Screenshot_2024-10-28_19-40-50_BPM_ring.png
  630   Mon Nov 28 08:54:20 2022 KD, VCUnder ProcessShift summaryLI shift du 28 Novembre 2022 

8h45 -9h :  - Démarrage frigo (pression entrée Frigo max ~ 5.5 bar). Le Frigo semble tenir et jouer son role. 

                  - Démarrage Modulateur (mise en chauffe)

                  - Démarrage Laser

                  * Le PSS est HS, il faut le redémarrer

9h15 : Arret Machine ==> intervention sur le pont de l'IGLOO. Reprise cette après midi si tout se passe bien. (SPR et autre nous ont pas prévenu).

10H30 : redpitaya en baie 17... (testées vendredi 25 )

redpitaya 2  connection impossible serveur éteind et starter serveur sous astor ne fonctionne pas  => Philippe G contacté par mail

redpitaya 1 3 4 les parametres (ATK pannel) Triger source=6 et trigger level=1) était à leurs valeurs par défaut ....  

Vérification de la lecture du phototube sur la voie B de la Redpitaya 4  => OK (attention la forme du signal à changé)

13h30 : Mise en chauffe modulateur. Le Frigo était en alarme "Haute température".

 

**** Problème ****

- L'IHM sst bug : faisceau sature et les boutons d'intensité ne semble pas agir. Bug d'affichage également sous les boutons gain et exposure time. Sinon l'interface est plutot agreable à utiliser

 

 

  1159   Thu Nov 27 08:01:20 2025 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 27 novembre 2025 

8h: mise en chauffe à distance (modulateur, frigo/chiller, laser, cyclage)

9h30: Chargement de la recette : "recipe_recipe_LI_TL_RI_all_20251126_09_35_14.txt" pour référence

ajustement energie linac et phase cavité RF pour réduire l'oscillation synchrotron.

10h43: prise de référence, dispersion -3cm

10h50: recette dispersion Viktor V1, dispersion -7.3cm

10h55: recette dispersion Viktor V2, dispersion +10.3cm

11h: essaie recette Julien, pas de charge transmise sur ict3. Faisceau très défocalisé et ligne trop fermée (très sensible aux petites variations pointé, énergie etc.)

11h30: essaie recette référence avec feedback injection ring

11h50: recette dispersion Viktor V3, dispersion -9.5cm

12h: effet stockage sur faisceau,

   1) le faisceau est stocké avec la recette de référence, optimisé avec la phase cavité RF et l'energie ==> faible oscillation synchrotron mais stockage instable (grosses pertes en fin de stockage)

   2) le faisceau est optimisé pour augmenté la qualité du stockage. Faible jitter d'injection et stockage stable (sans perte) mais grosses oscillations synchrotron

Les deux mesures de longueur de paquet montre qu'un mauvais stockage peut permettre d'avoir un meilleur faisceau en longitidinale alors qu'un bon stockage peu vite dégrader le faisceau. QUESTION: est ce uniquement en lien avec l'oscillation synchrotron ? Est ce que le fait que le faisceau soit vite dégradé améliore la stabilité du stockage ?

 

===> Au final il ne semble pas y avoir un fort impact sur les jitters en fonction des différents points de dispersion. Le point à 11h30, est le point de référence refait avec le feedback d'injection anneau, il semble moins bon.

Sur l'image le point marque la valeur moyenne et la barre d'erreur l'écart type des 100 mesures (jitter), pour BPM.02-LIB.03 (BPM1) et BPM.04-LIB.03 (BPM3)

 

*** Mesures faites pour chaque points ***

- mean / std, de 100 acquisitions des positions BPM X et Y (des 12 BPM de l'anneau) pour le numéro  buffer (0, 14, 100, 500, 1000, 1999)

- Archivage mesure le stockage et autre donnée

- image de l'orbite en comparaison avec la référence

- image oscillations synchrotron

- image TBTsum 

 

 

 

 

*** Programme ***

Injection stability en fonction de la dispersion 100 pC :

Quantify injector stability vs. TL dispersion

Goal: Understand and minimize the shot-to-shot jitter at ring injection by tuning TL dispersion.

Workflow:

Vary dispersion in the TL in a controlled way (use > 5 optics settings).

For each dispersion setting:

  • Measure horizontal and vertical jitter in the ring (turn-by-turn).
  • Record injected charge, storage efficiency and orbit offset at injection.

Try to match TL dispersion to ring dispersion at injection and identify the setting that minimizes jitter.

Summarise the best TL dispersion setting and assign it as standard optics.

Deliverables:

Jitter vs. TL dispersion curves.

TL optics for minimum jitter.

Beam time: ~2 shifts.

 

 

*** après midi ***

- problème RI-C1 QP.05, problème : electrodes désoudées ==> ressoudées avec Jean-Noel.

- immersion recherche : quelques images de radiofraphie (portable, carte banquaire, baume à lèvre) ==> cavité extrèmement instable !

17h45 : Stop ThomX

Attachment 1: multi_disps.txt
# Values shown are for the Downstream End of each Element (Girder at ref point):
# Index  name      key                      s       l          K1       eta_a      etap_a      beta_a     alpha_a      beta_b     alpha_b
      0  BEGINNING Beginning_Ele        0.000     ---         ---  0.0000E+00  0.0000E+00  3.4460E+01 -4.2400E+00  3.3940E+01 -4.3400E+00
      4  QP1L      Quadrupole           0.554   0.157 -2.8605E+00  0.0000E+00  0.0000E+00  4.2139E+01 -2.3069E+01  3.6267E+01  1.2050E+01
      8  QP2L      Quadrupole           0.904   0.157  1.2447E+01  0.0000E+00  0.0000E+00  4.3958E+01  6.8419E+01  3.8396E+01 -5.7609E+01
     10  QP3L      Quadrupole           1.254   0.157 -1.0657E+01  0.0000E+00  0.0000E+00  1.2759E+01  1.2781E+01  6.9835E+01  3.9379E+01
     16  QP4L      Quadrupole           2.800   0.157  1.3908E+01  4.3505E-01 -2.1774E-01  5.2671E+00  6.8472E-01  2.6443E+00  7.9127E-01
     25  QP5L      Quadrupole           6.083   0.157  4.3710E+00 -2.6604E-01 -4.0250E-02  3.3854E+00  2.1830E+00  4.5194E+00 -4.2245E+00
     29  QP6L      Quadrupole           7.329   0.157 -1.2013E+01  6.1162E-01  2.0776E+00  1.6670E+00 -6.3848E+00  1.7119E+01  2.5043E+01
     31  QP7L      Quadrupole           7.679   0.157  1.3694E+01  1.1540E+00 -3.2350E-01  6.8650E+00  1.0526E+00  6.1700E+00  8.0525E-01
     47  FIN_TL    Marker              12.161   0.000         ---  2.0372E-02 -3.5510E-05  3.4406E+00  1.1859E-02  2.7439E+00 -1.1781E-02


# Values shown are for the Downstream End of each Element (Girder at ref point):
# Index  name      key                      s       l          K1       eta_a      etap_a      beta_a     alpha_a      beta_b     alpha_b
      0  BEGINNING Beginning_Ele        0.000     ---         ---  0.0000E+00  0.0000E+00  3.4460E+01 -4.2400E+00  3.3940E+01 -4.3400E+00
      4  QP1L      Quadrupole           0.554   0.157 -2.8499E+00  0.0000E+00  0.0000E+00  4.2128E+01 -2.2998E+01  3.6277E+01  1.1991E+01
      8  QP2L      Quadrupole           0.904   0.157  1.2444E+01  0.0000E+00  0.0000E+00  4.3908E+01  6.8383E+01  3.8452E+01 -5.7739E+01
     10  QP3L      Quadrupole           1.254   0.157 -1.0662E+01  0.0000E+00  0.0000E+00  1.2730E+01  1.2781E+01  6.9970E+01  3.9458E+01
     16  QP4L      Quadrupole           2.800   0.157  1.3862E+01  4.3528E-01 -2.1481E-01  5.2761E+00  6.8065E-01  2.6438E+00  8.1676E-01
     25  QP5L      Quadrupole           6.083   0.157  4.3419E+00 -2.5678E-01 -4.4937E-02  3.4051E+00  2.1813E+00  4.5165E+00 -4.2290E+00
     29  QP6L      Quadrupole           7.329   0.157 -1.2022E+01  6.0629E-01  2.0548E+00  1.6625E+00 -6.3842E+00  1.7135E+01  2.5085E+01
     31  QP7L      Quadrupole           7.679   0.157  1.3711E+01  1.1422E+00 -3.2553E-01  6.8650E+00  1.0526E+00  6.1700E+00  8.0525E-01
     47  FIN_TL    Marker              12.161   0.000         ---  2.9109E-15 -3.5510E-05  3.4406E+00  1.1859E-02  2.7439E+00 -1.1781E-02


# Values shown are for the Downstream End of each Element (Girder at ref point):
# Index  name      key                      s       l          K1       eta_a      etap_a      beta_a     alpha_a      beta_b     alpha_b
      0  BEGINNING Beginning_Ele        0.000     ---         ---  0.0000E+00  0.0000E+00  3.4460E+01 -4.2400E+00  3.3940E+01 -4.3400E+00
      4  QP1L      Quadrupole           0.554   0.157 -2.8506E+00  0.0000E+00  0.0000E+00  4.2129E+01 -2.3002E+01  3.6276E+01  1.1995E+01
      8  QP2L      Quadrupole           0.904   0.157  1.2448E+01  0.0000E+00  0.0000E+00  4.3906E+01  6.8413E+01  3.8453E+01 -5.7762E+01
     10  QP3L      Quadrupole           1.254   0.157 -1.0663E+01  0.0000E+00  0.0000E+00  1.2716E+01  1.2797E+01  6.9987E+01  3.9466E+01
     16  QP4L      Quadrupole           2.800   0.157  1.3816E+01  4.3551E-01 -2.1189E-01  5.2913E+00  6.7717E-01  2.6419E+00  8.3734E-01
     25  QP5L      Quadrupole           6.083   0.157  4.3105E+00 -2.4757E-01 -4.9608E-02  3.4257E+00  2.1798E+00  4.5204E+00 -4.2339E+00
     29  QP6L      Quadrupole           7.329   0.157 -1.2028E+01  6.0096E-01  2.0320E+00  1.6581E+00 -6.3836E+00  1.7151E+01  2.5129E+01
     31  QP7L      Quadrupole           7.679   0.157  1.3728E+01  1.1305E+00 -3.2756E-01  6.8650E+00  1.0526E+00  6.1700E+00  8.0525E-01
     47  FIN_TL    Marker              12.161   0.000         --- -2.0372E-02 -3.5510E-05  3.4406E+00  1.1859E-02  2.7439E+00 -1.1781E-02


# Values shown are for the Downstream End of each Element (Girder at ref point):
# Index  name      key                      s       l          K1       eta_a      etap_a      beta_a     alpha_a      beta_b     alpha_b
      0  BEGINNING Beginning_Ele        0.000     ---         ---  0.0000E+00  0.0000E+00  3.4460E+01 -4.2400E+00  3.3940E+01 -4.3400E+00
      4  QP1L      Quadrupole           0.554   0.157 -2.8526E+00  0.0000E+00  0.0000E+00  4.2131E+01 -2.3016E+01  3.6274E+01  1.2006E+01
      8  QP2L      Quadrupole           0.904   0.157  1.2456E+01  0.0000E+00  0.0000E+00  4.3907E+01  6.8464E+01  3.8449E+01 -5.7784E+01
     10  QP3L      Quadrupole           1.254   0.157 -1.0666E+01  0.0000E+00  0.0000E+00  1.2697E+01  1.2821E+01  7.0000E+01  3.9468E+01
     16  QP4L      Quadrupole           2.800   0.157  1.3749E+01  4.3585E-01 -2.0761E-01  5.3147E+00  6.7242E-01  2.6411E+00  8.6497E-01
     25  QP5L      Quadrupole           6.083   0.157  4.2657E+00 -2.3404E-01 -5.6254E-02  3.4551E+00  2.1775E+00  4.5285E+00 -4.2408E+00
     29  QP6L      Quadrupole           7.329   0.157 -1.2037E+01  5.9327E-01  1.9985E+00  1.6517E+00 -6.3828E+00  1.7175E+01  2.5190E+01
     31  QP7L      Quadrupole           7.679   0.157  1.3752E+01  1.1134E+00 -3.3051E-01  6.8650E+00  1.0526E+00  6.1700E+00  8.0525E-01
     47  FIN_TL    Marker              12.161   0.000         --- -5.0000E-02 -3.5510E-05  3.4406E+00  1.1859E-02  2.7439E+00 -1.1781E-02


# Values shown are for the Downstream End of each Element (Girder at ref point):
# Index  name      key                      s       l          K1       eta_a      etap_a      beta_a     alpha_a      beta_b     alpha_b
      0  BEGINNING Beginning_Ele        0.000     ---         ---  0.0000E+00  0.0000E+00  3.4460E+01 -4.2400E+00  3.3940E+01 -4.3400E+00
      4  QP1L      Quadrupole           0.554   0.157 -2.8450E+00  0.0000E+00  0.0000E+00  4.2123E+01 -2.2964E+01  3.6281E+01  1.1964E+01
      8  QP2L      Quadrupole           0.904   0.157  1.2429E+01  0.0000E+00  0.0000E+00  4.3900E+01  6.8288E+01  3.8468E+01 -5.7716E+01
     10  QP3L      Quadrupole           1.254   0.157 -1.0657E+01  0.0000E+00  0.0000E+00  1.2760E+01  1.2741E+01  6.9966E+01  3.9449E+01
     16  QP4L      Quadrupole           2.800   0.157  1.3973E+01  4.3472E-01 -2.2185E-01  5.2383E+00  6.8967E-01  2.6569E+00  7.5983E-01
     25  QP5L      Quadrupole           6.083   0.157  4.4229E+00 -2.7897E-01 -3.3064E-02  3.3534E+00  2.1853E+00  4.5139E+00 -4.2169E+00
     29  QP6L      Quadrupole           7.329   0.157 -1.2003E+01  6.1951E-01  2.1104E+00  1.6740E+00 -6.3857E+00  1.7093E+01  2.4975E+01
     31  QP7L      Quadrupole           7.679   0.157  1.3667E+01  1.1710E+00 -3.2055E-01  6.8650E+00  1.0526E+00  6.1700E+00  8.0525E-01
     47  FIN_TL    Marker              12.161   0.000         ---  5.0000E-02 -3.5510E-05  3.4406E+00  1.1859E-02  2.7439E+00 -1.1781E-02
Attachment 2: recipe_recipe_LI_TL_RI_all_20251126_09_35_14.txt
LI/PS/COL.01/currentSetpointPM : <type 'float'> : 66.47
LI/PS/COL.02/currentSetpointPM : <type 'float'> : 230.0
EL/PS/QP.01/currentSetpointPM : <type 'float'> : -3.94
EL/PS/QP.02/currentSetpointPM : <type 'float'> : 5.13
EL/PS/QP.03/currentSetpointPM : <type 'float'> : -2.47
EL/PS/QP.04/currentSetpointPM : <type 'float'> : -3.28
EL/PS/QP.05/currentSetpointPM : <type 'float'> : 3.01
EL/PS/QP.06/currentSetpointPM : <type 'float'> : 1.99
EL/PS/QP.07/currentSetpointPM : <type 'float'> : -2.84
LI/PS/STR.01-H.01/currentSetpointPM : <type 'float'> : 0.744495394655
LI/PS/STR.01-V.01/currentSetpointPM : <type 'float'> : -2.55611182033
LI/PS/STR.02-V.01/currentSetpointPM : <type 'float'> : 3.14718161006
LI/PS/STR.02-H.01/currentSetpointPM : <type 'float'> : -2.87618448919
EL/PS/STR.02-V.01/currentSetpointPM : <type 'float'> : 0.0
EL/PS/STR.02-H.01/currentSetpointPM : <type 'float'> : 8.0
TL/PS/QP.01/currentSetpointPM : <type 'float'> : -0.1700483772
TL/PS/QP.02/currentSetpointPM : <type 'float'> : 3.5
TL/PS/QP.03/currentSetpointPM : <type 'float'> : -3.40148253
TL/PS/QP.04/currentSetpointPM : <type 'float'> : 2.02
TL/PS/QP.05/currentSetpointPM : <type 'float'> : 2.02
TL/PS/QP.06/currentSetpointPM : <type 'float'> : -3.7
TL/PS/QP.07/currentSetpointPM : <type 'float'> : 3.7
RI-C1-C2/PS/SP.03/currentSetpointPM : <type 'float'> : -1.83626944534
RI-C1/PS/QP.01/currentSetpointPM : <type 'float'> : 3.06436602905
RI-C1/PS/QP.02/currentSetpointPM : <type 'float'> : -1.44273612065
RI-C1/PS/QP.03/currentSetpointPM : <type 'float'> : -1.75851554175
RI-C1/PS/QP.04/currentSetpointPM : <type 'float'> : 3.25098431127
RI-C1/PS/QP.05/currentSetpointPM : <type 'float'> : -3.62669034804
RI-C1/PS/QP.06/currentSetpointPM : <type 'float'> : 2.41679703056
RI-C1/PS/QP.07/currentSetpointPM : <type 'float'> : 5.37507690285
RI-C1/PS/QP.08/currentSetpointPM : <type 'float'> : -6.01739765821
RI-C1/PS/QP.09/currentSetpointPM : <type 'float'> : -6.1066305017
RI-C1/PS/QP.10/currentSetpointPM : <type 'float'> : 5.42107968349
RI-C1/PS/QP.11/currentSetpointPM : <type 'float'> : 2.41073325341
RI-C1/PS/QP.12/currentSetpointPM : <type 'float'> : -3.74160359773
RI-C1-C2/PS/SP.01/currentSetpointPM : <type 'float'> : 0.276011295791
RI-C2/PS/QP.01/currentSetpointPM : <type 'float'> : 3.27755669647
RI-C2/PS/QP.02/currentSetpointPM : <type 'float'> : -1.59686996779
RI-C2/PS/QP.03/currentSetpointPM : <type 'float'> : -1.84944684805
RI-C2/PS/QP.04/currentSetpointPM : <type 'float'> : 3.33472861937
RI-C2/PS/QP.05/currentSetpointPM : <type 'float'> : -3.63782047595
RI-C2/PS/QP.06/currentSetpointPM : <type 'float'> : 2.37550666969
RI-C2/PS/QP.07/currentSetpointPM : <type 'float'> : 5.33582360514
RI-C2/PS/QP.08/currentSetpointPM : <type 'float'> : -6.03274378372
RI-C2/PS/QP.09/currentSetpointPM : <type 'float'> : -5.99504206123
RI-C2/PS/QP.10/currentSetpointPM : <type 'float'> : 5.31153116544
RI-C2/PS/QP.11/currentSetpointPM : <type 'float'> : 2.48463744172
RI-C2/PS/QP.12/currentSetpointPM : <type 'float'> : -3.76741453121
RI-C1-C2/PS/SP.02/currentSetpointPM : <type 'float'> : 3.81502301981
TL/PS/STR.01-V.01/currentSetpointPM : <type 'float'> : 0.0
TL/PS/STR.01-H.01/currentSetpointPM : <type 'float'> : 0.0
TL/PS/STR.02-V.01/currentSetpointPM : <type 'float'> : -8.0
TL/PS/STR.02-H.01/currentSetpointPM : <type 'float'> : -3.0
TL/PS/STR.03-V.01/currentSetpointPM : <type 'float'> : 0.794
TL/PS/STR.03-H.01/currentSetpointPM : <type 'float'> : 7.716
TL/PS/STR.04-V.01/currentSetpointPM : <type 'float'> : 4.753
TL/PS/STR.04-H.01/currentSetpointPM : <type 'float'> : 6.428
TL/PS/DPI.01/currentSetpointPM : <type 'float'> : 7.938
RI-C1/PS/STR.01-V.01/currentSetpointPM : <type 'float'> : 4.00889873052
RI-C1/PS/STR.01-H.01/currentSetpointPM : <type 'float'> : -2.94482865272
RI-C1/PS/STR.02-V.01/currentSetpointPM : <type 'float'> : -0.987669112358
RI-C1/PS/STR.02-H.01/currentSetpointPM : <type 'float'> : -1.76585719278
RI-C1/PS/STR.03-V.01/currentSetpointPM : <type 'float'> : -3.26026864154
RI-C1/PS/STR.03-H.01/currentSetpointPM : <type 'float'> : 0.00371314934889
RI-C1/PS/STR.04-V.01/currentSetpointPM : <type 'float'> : 5.72251814247
RI-C1/PS/STR.04-H.01/currentSetpointPM : <type 'float'> : 0.0969259217919
RI-C1/PS/STR.05-V.01/currentSetpointPM : <type 'float'> : 0.132553818996
RI-C1/PS/STR.05-H.01/currentSetpointPM : <type 'float'> : -2.59504238267
RI-C1/PS/STR.06-V.01/currentSetpointPM : <type 'float'> : -1.79567757428
RI-C1/PS/STR.06-H.01/currentSetpointPM : <type 'float'> : -4.85981209589
EL/PS/STR.01-H.01/currentSetpointPM : <type 'float'> : 0.0
EL/PS/DPI.01/currentSetpointPM : <type 'float'> : 0.0
RI-C2/PS/STR.01-V.01/currentSetpointPM : <type 'float'> : -2.71485643949
RI-C2/PS/STR.01-H.01/currentSetpointPM : <type 'float'> : -6.0376417579
RI-C2/PS/STR.02-V.01/currentSetpointPM : <type 'float'> : -0.664835392405
RI-C2/PS/STR.02-H.01/currentSetpointPM : <type 'float'> : -1.54646010356
RI-C2/PS/STR.03-V.01/currentSetpointPM : <type 'float'> : 4.28475016291
RI-C2/PS/STR.03-H.01/currentSetpointPM : <type 'float'> : 3.84379917319
RI-C2/PS/STR.04-V.01/currentSetpointPM : <type 'float'> : -7.71572597127
RI-C2/PS/STR.04-H.01/currentSetpointPM : <type 'float'> : 1.18413063336
RI-C2/PS/STR.05-V.01/currentSetpointPM : <type 'float'> : 0.586667664296
RI-C2/PS/STR.05-H.01/currentSetpointPM : <type 'float'> : 0.784765660279
RI-C2/PS/STR.06-V.01/currentSetpointPM : <type 'float'> : 1.86755579082
RI-C2/PS/STR.06-H.01/currentSetpointPM : <type 'float'> : 1.36213305755
EL/PS/STR.01-V.01/currentSetpointPM : <type 'float'> : 0.0
RI-C1/PS/DP.01/currentSetpointPM : <type 'float'> : 159.3
TL/PS/DP.01/currentSetpointPM : <type 'float'> : 159.3
EL/PS/DP.01/currentSetpointPM : <type 'float'> : 159.3
er/pe/inj_kick_ps/Voltage : <type 'float'> : 6344.0
er/pe/inj_kick_ps/Current : <type 'float'> : 40.0
er/pe/ext_kick_ps/Voltage : <type 'float'> : 6344.0
er/pe/ext_kick_ps/Current : <type 'float'> : 40.0
er/pe/pass_sept_ps/Current : <type 'float'> : 6.0
er/pe/pass_sept_ps/Voltage : <type 'float'> : 96.1500015259
TEST/HL/ThomX_PhotoCathode/Horizontal_Iris_Position_set : <type 'float'> : 5.003
TEST/HL/ThomX_PhotoCathode/Vertical_Iris_Position_set : <type 'float'> : 4.553
Attachment 3: Beam_no_opt.tif
Attachment 4: Beam_opt.tif
Attachment 5: BPM_jitters.png
BPM_jitters.png
  1023   Thu Feb 27 07:37:25 2025 KD, VM, SK, NDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 27 février 2025 

7h45: mise en chauffe en remote (Frigo/chiller, laser, cyclage aimants)

Le Modulateur ne répond pas et ne veut pas passer en STANDBY ==> need to go on site

Problème d'intelock sur le refroidissement d'eau ==> redémarrage du PC modulateur ==> problème résolu ==> mise en chauffe à 8h30

9;35 Modulateur en trig

Receipt from 20250226_15_02_26

9:57 Beam in ring, Xray

RF Gun phase is 25 dg., Sect. phase is 206 dg., Att. 2.56 dB, TL/BPM2 SPx=2 mm. Charges from BPMs: -85 pC, -83 pC, -91 pC Linac steerers as in the receipt.

RF Cav. Volt. 200 kV, 35 dg.

11h45 Sum of the TBTSum =1.15e11, FPC power is 88 W, I3 current around 20000 pA, the kicker voltage was set to 9368 V (about 11h10) to rise X ray flux

12.30 RF Gun phase was set to 22 dg. to rise flux to 20000 pA, TL/BPM2 SPx=3 mm

15h42 The gun phase was set to 10 dg. sect phase 203 dg. with TL/SST2. TL/BPM2 SPx=2 mm

17:42 Stop ThomX

Attachment 1: Screenshot_from_2025-02-27_14-16-16.png
Screenshot_from_2025-02-27_14-16-16.png
Attachment 2: Screenshot_from_2025-02-27_14-10-50.png
Screenshot_from_2025-02-27_14-10-50.png
Attachment 3: Screenshot_from_2025-02-27_14-10-37.png
Screenshot_from_2025-02-27_14-10-37.png
Attachment 4: Screenshot_from_2025-02-27_14-10-27.png
Screenshot_from_2025-02-27_14-10-27.png
Attachment 5: Screenshot_from_2025-02-27_14-10-12.png
Screenshot_from_2025-02-27_14-10-12.png
Attachment 6: Screenshot_from_2025-02-27_14-09-57.png
Screenshot_from_2025-02-27_14-09-57.png
Attachment 7: Screenshot_from_2025-02-27_14-09-26.png
Screenshot_from_2025-02-27_14-09-26.png
Attachment 8: Screenshot_from_2025-02-27_14-07-47.png
Screenshot_from_2025-02-27_14-07-47.png
Attachment 9: Screenshot_from_2025-02-27_14-07-37.png
Screenshot_from_2025-02-27_14-07-37.png
Attachment 10: 2025-02-27_09_49_32_tl_dg_sst_01-ccd_01_RAW.png
2025-02-27_09_49_32_tl_dg_sst_01-ccd_01_RAW.png
Attachment 11: 2025-02-27_09_49_14_tl_dg_sst_01-ccd_01_RAW.png
2025-02-27_09_49_14_tl_dg_sst_01-ccd_01_RAW.png
Attachment 12: 2025-02-27_09_46_34_li_dg_sst_01-ccd_01_RAW.png
2025-02-27_09_46_34_li_dg_sst_01-ccd_01_RAW.png
  742   Wed Apr 26 19:03:56 2023 Entered by Marie Jacquet from 134.158.89.45 on Wed Apr 26 19:03:42 2023 Shift summaryLinac Commissionning shift du 26/04 - Quads scans + stabilite 

1) Quad scans Isol = 155, 175, 190, 200, 220 pris avec script classique ET avec script FWHM LIMA - Taille a comparer, pour voir ... A TRAITER, resultats a suivre

2) Mesure longue de stabilite  (c'etait tres stable comme ca a l'oeil) - A TRAITER, a quantifier avec plots a suivre.

  923   Thu Sep 26 08:13:40 2024 KD, NDUnder ProcessShift summaryLinac Commissionning shift du 26 septembre 2024 

8h15: Mise en chauffe du modulateur et des chillers. Défaut Laser à investiguer pour la mise en route ("flow interlock")

9h: démarrage Laser PC (problème de niveau d'eau résolu)

9h19: Defaut sur RI-C2/QP2 a 6% du cyclage

9h20 Pression 2,5bars, bouteille retiree.

Phase section: 229.

Attenuation: 2.56dB en venant de 2.7dB (Attention, au backlash)

Apparement, il y a un backlash d'environ 0.1dB sur l'attenuateur.

10h08 Modulateur passe a OFF soudainement, status bit 8

Faisceu redemarre

Pour les quad RI-C2/QP2: Cyclage etait a 9A, cyclage limite a 7.5A. Cela devrait fonctionner. 

En cyclant les dipoles de l'anneau on ameliore le transport dans la EL... Mettre RI-C1/QP.01 a 250A.

Bruit sur EL/BPM.01, electrode B: Apparement le bruit viens du cable jaume branche en C3 sur le chassis du libera 01

Le faisceau sur EL/SST.01 est coupe si EL/DPI.01 est supérieur à -7.40A 

Recette sauvee pour transport jusqu'a EL/SST.01: TL_good_20240926_14_21_58

 

Problème de synchro qui saute : 

* Le problème semble venir de la CPLD (cf. Screenshot_2024-09-26T13-25-29), courbe jaune = sortie trigger box pour RING, bleue = sortie trigger box pour modulateur

* Le modulateur semble bien etre à 50Hz, en revanche les autres trig (anneau) ne sont pas à 10Hz comme demandé

* la phase des signaux (rigole ou laser) ont un influence sur le comportement. 

* Changement du MCT2E mais le problème de commutation sur le signal 50Hz en sortie persiste (cf. Screenshot_2024-09-26T14-38-19), courbe bleue = sortie du MCT2E

==> peut etre le transistor avant ou un défaut de masse ?. 

  - Le problème semble lié à cette commutation visible sur les signaux en sortie de trigger box (cf. Screenshot_2024-09-26T14-49-02)

  - test effectués :

      -- changement des niveaux des signaux (Laser et 33MHz),

      -- changement des phases (Laser et 33MHz),

      -- reboot de la carte CPLD,

      -- changement des codes fréquences,

      -- mise en test d'une résistance sur la "bobine 50Hz" en entrée de trigger box

* Le problème n'est pas présent quand la machine est à l'arrêt. Un équipement vient perturber les signaux. (cf. Screenshot_2024-09-27T05-41-07), une fois la machine éteinte.

==> Il faut investiguer la source de bruit et/ou s'en affranchir (mise en place d'un filtre)

Etude retard EL/DG/SST.01

17h58: Arret 

Attachment 1: Screenshot_2024-09-26T13-25-29.jpg
Screenshot_2024-09-26T13-25-29.jpg
Attachment 2: Screenshot_2024-09-26T14-38-19.jpg
Screenshot_2024-09-26T14-38-19.jpg
Attachment 3: Screenshot_2024-09-26T14-49-02.jpg
Screenshot_2024-09-26T14-49-02.jpg
Attachment 4: Screenshot_2024-09-27T05-41-07.jpg
Screenshot_2024-09-27T05-41-07.jpg
  1158   Wed Nov 26 07:47:52 2025 KD MJ VM DN RCUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 26 novembre 2025 

7h50: mise en chauffe à distance (frigo/chiller, laser, modulateur, cyclage)

11h13 Beam is in the ring, 50 MeV, RF gun phase 268 dg. ==> 272 dg., Sect. phase 211 dg., Sect. Att. 2.35 dB. Linac sreerers H [0.74 -2.98], V [-2.56 3.0], Charges (BPMs) -112, -107, -112, -110 pA 

16h: essaye de la recette "Mad180" pour injection dans l'anneau. Impossible car pas de charge transmise sur l'ict3

17h: changement solénoïde 180 --> 230A, on a un peu de charge transmise (70pC pour 100pC). +1A sur QP5 afin d'avoir un faisceau focalisé sur TL/BPM.03. Injection faible possible mais très sensible à la sortie linac (après 2 min plus de charge transmise ==> ligne trop fermée)

*** Spectres a differentes valeurs de bpmTL2_X, et avec la meme orbit a l'IP

bpmTL2 =  0 (~ 11h55)
spectre

bpmTL2 = - 4 (~ 12h00)
spectre
Image fente 1 ==> Taille source X : X = 310 , Y = 51 

bpmTL2 = - 2 (~ 12h17)
spectre
Image fente 1 ==> Taille source X : X = 179 , Y = 45 

bpmTL2 =  0 (~ 12h24)
spectre
Image fente 1 ==> Taille source X : X = 201 , Y = 58

bpmTL2 = + 4 (~ 12h35)
spectre
Image fente 1 ==> Taille source X : X = 170 , Y = 67

bpmTL2 = + 2 (~ 12h45)
spectre
Image fente 1 ==> Taille source X : X = 268 , Y = 62

bpmTL2 = 0 (~ 12h53)
spectre
Image fente 1 ==> Taille source X : X = 234 , Y = 53

 

** Spectre pris a differentes positions de detecteur

 

** Mesures avec diode calibree

~ 13h56 : diode alignee dans le faisceau (au centre, a la louche) - Fente2 : H = + 2 , V = - 11

Quelques deplacements dans le faisceau :
   fente2 : H = + 2 ;  V = - 11 ( ~ 14h55)
   fente2 : H = + 2 ;  V = - 21 ( ~ 15h01)
   fente2 : H = + 10 ; V = - 21 ( ~ 15h05)
   fente2 : H = - 10 ;  V = - 21 ( ~ 15h07)

** Mesures longeur de paquet et injection

- Comparaison en fonction de la qualité du stockage:

   * mesure de la longueur pour l'anneau non optimisé (après dérive), il y a des oscillations synchrotrons (~4mm pic-pic), le stockage est pas stable

   * mesure de la longueur une fois l'anneau réoptimisé (énergie + 3° cavité RF)

- Comparaison taille faisceau VS amplitude cavité RF 

==> pas d'effet visible du FBL (il faut peut être l'ajuster)

=====================================================================

Programme du jour : Spectres a differentes positon bpmTL2_X, avec meme orbite a l'IP

 

Attachment 1: Ring_CavityRamp.png
Ring_CavityRamp.png
Attachment 2: Ring_optVSnoopt.png
Ring_optVSnoopt.png
Attachment 3: 20251126_1ms_cavityRAMP_250kV.tif
Attachment 4: 20251126_1ms_150kV_no_opt.tif
Attachment 5: 20251126_1ms_150kV_opt.tif
Attachment 6: 20251126_1ms_250kV_noFBL.tif
Attachment 7: 20251126_1ms_cavityRAMP_150kV.tif
Attachment 8: 20251126_1ms_cavityRAMP_200kV.tif
  Draft   Tue Nov 26 07:53:39 2024 MJ RC KDUnder ProcessShift summaryLaser | Opt | Linac Commissionning | Ring Commissioning shift du 26 novembre 2024 

8h : mise en chauffe en remote (laser, modulateur, frigo, chiller, cyclage)

10h48 : mise en route du feedback sur l'injection dans la section (1essai = erreur de signe sur le signal d'erreur), 2e essai (1min plus tard) semble ok, on laisse le feedback pour la stat.

Remarques :

** Kicker d'extraction instable. (extraction après stockage ok), sans steerer

** faisceau de rayons-X bouge en fonction de la phase e-/laser CFP

*** Programme ***

* mise en place feedback injection linac

10h48 : mise en route du feedback sur l'injection dans la section (1essai = erreur de signe sur le signal d'erreur), 2e essai (1min plus tard) semble ok, on laisse le feedback pour la stat. 
Avec feedback injection linac position bpm et charge beaucoup plus stables (data dans repertoire TRENDS)

* trend de flux avec asservissement du pointé d'injection

(fait vers 13h30, data a retrouver dans le trend generale fluo_diode ...)

* affinement de la position du 0 du faisceau X et mesure spectre angulaire

Fait 

Spectres acquis:

** Avec ecran fluo dans le faiscau (ca ne saturait donc pas, mais spectres tres elargiS par diffusion multiples)
** Ecran fluo retracte + desynchronisation pour ne pas que le det Amptek CdTe sature
spectre enregistres

* prise d'une image du faisceau de rayons X

Fait

Remarques :

** Kicker d'extraction instable. (extraction après stockage ok), sans steerer

** Le centre du faisceau de rayons X bouge de plusieurs centimetres (sur la camera dans la X-hutch) en fonction de la phase e-/laser CFP

Attachment 1: 2024-11-26_12_22_06_el_dg_sst_01-ccd_01_RAW_1.png
2024-11-26_12_22_06_el_dg_sst_01-ccd_01_RAW_1.png
  785   Wed Jul 26 09:01:34 2023 KDUnder ProcessShift summaryLaser | Opt shift du 26 juillet 2023 

9h : mise en chauffe de la machine (frigo, chiller, modulateur, laser) + "start cycling all magnets" dans IHM

11h: début de la prise de donnée

** recentrage des fentes 1 de la ligne X sur le flux compton. Prise du spectre de référence (position flux max ouverture fente1 3mmx3mm ==> utiliser la calibration de la veille)

** essaye de la diode calibrée ==> impossible à lire, courant négatif trop important (changer de pico pour lire les courant négatif ou prendre un oscilloscope)

** essaye de la caméra X

         -- prise d'une image du flux compton (stiching du faisceau à faire = images prise reste à traiter)

         -- estimation du flux à la caméra donne environs 10⁶ - 10⁷ ph/s 

** optimisation de l'ouverture et position de fentes 1 avec la caméra.

===> le faisceau n'est pas centrée sur le tube X, quid de la direction du faisceau d'électron ?

18h : arrêt machine

 

*** Remarques ***

- CFP instable et nécessite un opérateur en permanence

- Injection dans l'anneau et optimisation vers 10h30 puis aucune action sur la machine de la journée ==> Machine très stable aujourd'hui ! 

 

** Programme **

- fin de réglage fente 1 LigneX

- optimisation de la position fente 1 sur le spectre X

- mesure du flux total si possible

- image du faisceau si possible

- scan faisceau d'électron avec la table CFP et mesure en parallèle des paramètres faisceaux (puissance laser + charge stockée)

Attachment 1: image_00123.jpg
image_00123.jpg
Attachment 2: reference_spectrum_ThomX.bmp
Attachment 3: spectre_ref_diode.mca
<<PMCA SPECTRUM>>
TAG - live_data
DESCRIPTION - 
GAIN - 4
THRESHOLD - 0
LIVE_MODE - 0
PRESET_TIME - 0
LIVE_TIME - 130.769407
REAL_TIME - 132.117000
START_TIME - 07/26/2023 14:57:57
SERIAL_NUMBER - 0
<<DATA>>
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
2
9
4
4
2
5
6
7
5
8
7
7
... 3880 more lines ...
  Draft   Wed Feb 26 07:30:15 2025 KDUnder ProcessShift summaryLinac Commissionning | Ring Commissioning shift du 26 février 2025 

7h30: mise en chauffe en remote (Modulateur, frigo/chiller, laser, cyclage aimants)

8h35 HV is 'On'
base recipe all_2025225_14_52_23
10H
changement température canon consige à 31.7°C => moins  de réfléchi => retour à 31.6°C
Faisceau stocké dans anneau: Phase canon 24° 85pC Phase section 203° att section 2.43dB, TL/BPM2 TBTX=3mm,
RF power 200KV, Phase 35 dg.
FP power 90KW
T canon 31.55°C

 

 

 

 

 

 

  1128   Thu Sep 25 08:17:57 2025 KD, VM, ICUnder ProcessShift summaryRing | Ring Commissioning shift du 25 septembre 2025 

8h05: mise en chauffe en remote de la machine (modulateur, frigo/chiller, laser)

==> cyclage aimant plante, donc aimant non allumés ni cyclé.

9h All keys are in vertical position. Totes rondes sont tombees. We need help to restart.

Kevin and Vincent came to help.

All systems were started.

We switch on the RF and found problem with the reflected RF power in the gun. Checked the temperature and found that chiller failed to set the proper temperature.

10h10 Restart frigo+chiller

Several restarts but the temperature does not rise. 

After several attempts it is OK

11h Problem with laser, we do nto see the dark current on the ICT1; Try to understand the reason

Laser was not aligned. Kevin helped.

We restarted all the Liberas as they were not in a good state. 

The phase shifter DS was OFF.

11h50 Finally we have the beam in the ring

problem with the RIC1 STR 4 VERT It does not take the command and stays in the orange state. Steerer resistance is 18 Ohm.

12h02 F Gun phase 283 dg. Sect Att. 2.32 dB. Sect. phase 218 dg. Beam charges about -100 pC. Charge devices do not show values

Restart all Liberas because of reading problems

Srudies of the RF freq change. it is clear that it changes the phase of the RF cavity. Not clear if it is OK for th e measurements.

=> It is very important to measure the deltaPhase introduced by the RF transport lines in order to proceed with the measurements.

The vert cteere in the ring shuld be checked/repaired.

Stop for lunch and steerer reparation.

13h20 Jean-Noel came to help and check the steerer. Overvoltage on the PS. Access to the casemat. 

14h11 RIC1 STR 4 VERT fixed by Jean-Noel

14h14 HV is 'ON'

15h Studies of the vetical orbit and its compensation

17h Optics measurements. 

 

 

 

 

Attachment 1: Screenshot_from_2025-09-25_12-16-58.png
Screenshot_from_2025-09-25_12-16-58.png
Attachment 2: Screenshot_from_2025-09-25_17-43-12.png
Screenshot_from_2025-09-25_17-43-12.png
Attachment 3: Screenshot_from_2025-09-25_17-05-57.png
Screenshot_from_2025-09-25_17-05-57.png