LS,ND; run du 30 juin 2023 
|
9:00 Warm up machine
10:40 Start the beam
10:50 Scan charge phase
11:15 Storage in ring
Recipe: recipe_recipe_LI_TL_RI_test_20230629_16_44_31.txt
11:30 Studies of losses with fiber inside ring
12:30 Start RF cavity
13:00 Scan phase cavity
|
LS, ND; shift du 29 juin 2023
|
9:45 Git pull
Test des interfaces... OK
Probleme sur les ecrans du compte operateur ThomX (4x1 ecran) meme apres redemarrage => reconfiguration
10:10 Mise en chauffe
Interlock sur les aimants vu pendant le cyclage. Resolu.
11:30 Faisceau
12:05 Allumage cavite anneau (MEK)
12:15 Perte faisceau...
Apparement le PA avait disjoncte. Intervention MO.
13:00 Retour faisceau
Prise de données TL/FC01
13:30 Transport dans EL, essaie d'amélioration du transport : on a réussi à transporter environ 1/3 de la charge
Prise de données dans EL/FC01
15:00 Stockage dans anneau, optimisation
16:00 Prise de données pour étudier les pertes dans les fibres.
Prise de données des pertes:
-sans faisceau, avec juste kicker d'injection, septum, ou kicker d'extraction
-sans faisceau, avec tous les EP : obtenir bruit de fond
-avec faisceau, avec juste kicker d'injection, septum, ou kicker d'extraction
-avec faisceau: prise de données avec différents timing pour le kicker d'extraction => extraire le faisceau pour comprendre le timing de l'acquisition et observer les pertes avec différents timing de d'extraction |
ND, LS; ThomX operations 26/6
|
9:26 Mise en chauffe
9:40 Cycling the magnets
11:45 Beam ON
12:23 Study signal in FC
WAC2 delay: -6.15us
WAC3 delay: -6.45us
12:30 Prise image TL/FC.01
12:45 Difficultés allumage kicker extraction
13h45 Trasnport dans EL jusqu'à l'écran
14h33 Visualisation du signal dans EL/FC.01 => changement retard synchro sur WAC3
17h15 Arret Machine |
all; X detectes aujourd'hui
|
Aujourd'hui on a detecte des X en mode desynchro (notre signal correspond a ~ 3.10**6 ph/sec)
*** Pour :
- 100 pC stockee pendant 100 ms
- 30 kW dans la cavite
- mode desynch
- taille e- ~ 150 micons rms,
notre estimation du courant dans la p-diode det Fluo ligne X etait de ~ 25 pA
*** Trend de la p-diode ecran fluo ligneX en pj.
*** Tests realises pour etre surs :
On a delocke le laser : bruit laser ~ 20 pA sur notre pdiode
On a ferme puis ouvert le shutter e- laser locke : aucune difference de signal sur la p-diode (= aucun bruit venant du stockage des e-)
On a verifie qu'en bougeant "beaucoup" la table FPC en config shuter e- ferme, le signal du au laser FPC etait le meme
On a bouge la table en verticale et horizontal suffisamment pour identifier un maximum sur le signal.
Merci a tous et bon we
|
VK, IC, DN, RC, JN; search for X-rays
|
8h30 Start of the modumator, laser, magnet cycling
9h45 Beam is ON. Scan charge vs. RF phase.
Attribute Li/OP/OPT.01-ATT.01 is showing value 340mm, this is different from the nominal ones of 300-303. Charge to be remeasured at nominal ones.
|
Entered by Marie Jacquet from 134.158.89.45 on Thu Jun 22 19:39:22 2023; recherche IP e-/laser
|
** Au vu de ce shift tres instructif d'aujourd'hui, pour demain:
1) Le sens le moins chronophage des scans table FPC sont:
Partir en Ty negatif, et aller vers Ty pos
Paritr en Tz positifs, et aler vers Tz neg
2) Avoir de visu les panneaux "charge" et "Stockage anneau" sur le meme ecran que l'intensite p-diode xline car aujourd'hui il n'y avait plus rien de stocke pendant un certain temps (inconnu) sans que ceux qui cherchent les X le sachent
3) Se mettre au point de fonctionnement anneau ~90% de stockage et non 30% comme aujourd'hui (facteur 3)
4) Se mettre et faire en sorte de rester a 100 pC, tout le temps, et pas autour de 50 voire moins comme c'etait le cas souvent aujourd'hui (facteur ~2)
** On a scane, sans succes :
Tz de 0 a 1.9 mm . La CFP perd un facteur 2 vers Tz = 1.5 mm, un facteur 10 vers Tz = 1.9 mm
Tz de 0 a ~ -3 mm CFP a delocke ensuite, on a decider de passer a Ty sans aller plus loin en Tz
Ty de 0 a 2.5 mm (maximum autorise)
Tz de 0 a -3.9 mm pour Ty = -2.5mm
Tous ces scans ont ete faits sans savoir en direct quelle etait la charge et le stockage, et donc ils sont a refaire dans les conditions 2), 3) et 4)
|
Entered by Marie Jacquet from 134.158.89.45 on Thu Jun 22 11:43:12 2023; Bruit de fond diodes ligneX
|
| |
ND, LS, MB, DN, MA, IC, VK, MEK, JNC, MJ, RC; X-rays attempt 22/06 10x
|
9:23: Mise en chauffe
9:29 Cycle magnets
10:20 Acces casemate cavite CFP
10:49 Beam ON Phase=268
11:02 Phase RF linac = 109
11:14 Faisceau dans l'anneau
Recette: all_20230616_16_51_29
11:15 Faisecau stocke
11:30 Reglages cavite RF en cours
11:46 10kW dans la cavite CFP
Ring RF Cavity 60kV
Phase 5.41V sur les deux dephaseurs SY
Freq = 500.33MHz
Recherche des X
16:20 Faisceau dans la ligne d 'extraction apres passage dans l 'anneau.
Transmission dans l 'anneau:
75% a l 'injection
35% en stockage
Rapport de charge EL/BPM.01/TL/BPM.04: 20% (compatible avec les valeurs ci-dessus)
Timing WAC.03 -6.93us.
Recette sauvee sous LI_TL_RI_good_20230622_16_21_36
17h15 Perte faisceau Scan charge vs phase + regage dispoersion refait
|
VK, IC. VM, AL, ND, LS; Orbit correction, optimization of the storage, study of the RF frequency 8x
|
9h30 Start of the modulator and lasser (GATE is closed).
9h46 Data is taken as background.
Cavity is tuned to 500.38 MHz. Optimization of the energy and phase.
RF cavity OFF. After previous tuning, the orbit is the same. Based on the simple calculation, to match to orbits, the RF frequency should be reduced by 60 khz.
New tuning of the cavity at 500.32 MHz.
After energy and phase optimization, the storage is obtained with a small dispersive orbit. Probably the real frequency is 500.33 MHz.
Test to decreaase the frequency to see at which frequency we can operate with the FPC if needed. Tuning of the cavity at 500.22 MHz. No storage obtained.
New test at 500.27 MHz. The beam storage is obtained with the dispersive orbit. Machine is depleted. At the moment the lowest frequency at which we can potentially operate is 500.27 MHz.
Coming back to the machine frequency of 500.33 MHz. Storage is obtained. Optimization to be done.
Data are taking at each configiration.
During the shift, we monitored the beam losses measured by 3 connected fibers. The turn-by-turn losses are clearly visible. |
VK, IC. VM; Orbit correction, BLM in the Ring 7x
|
The BLM detector boxes were installed in the ring. We connected 3 fibers and 2 scintillator detectors in th ring to be able to observe the beam losses.
Cabling, connection and checks of the BLM without the beam.
Machine start-up. Modulator was switched on at ~9h30.
Good storage.
Check of the injector and injection in the ring. Looking for the signal of the BLM withthe beam. Sucesfully; the signal was found with the fibers (see the screenshot attached).
Strange behaviour with the storage shot-by-shot: better and worse storage. Nicolas, Jean-Noel and Mohamed is trying to check it. All the chain from the synchro generator to the RF cavity was checked and it is OK. To be investigated. |
VK, IC. VM; Srart of the beam physics measurements 14x
|
The main idea fo this week is to prepare the beam for the search of the first X-rays.
Start machine without RF cavity. During the day several reboot of the libera.02 (TL).
Study of the dispersion. Measurements of the horizontal dispersion by changing the injector energy (RF section attenuator).
Orbit correction.
Study of the tune. Tune response with the steptune. Tune measurements.
First try to measure the horizontal beta function at the quadrupoles.
RF Cavity ON. Good storage at 50 kV 500.38 MHz. Dispersive orbit. SHould understand how to reduce it.
Different studies on the orbit.
Observations: position at the TL/DG/BPM.02-LIB.02/SpX drifts a lot (a few mm range) all day long. We should correct it all the time to keep the beam orbit and storage. |
VK, IC. VM, ND, LS; beam storage   
|
The main idea fo this week is to prepare the beam for the search of the first X-rays.
Start without RF cavity. Study of the orbit. Orbit correction. We menage to correct hor. and vert. orbit.
We put the RF cavity ON. A lot of interlocks during the day. Difficult to operate i this conditions.
Optimization of the storage.
Orbit corresponds to the disperive orbit. Should look at this. Maybe tune the frequency.
Very good storage was obtained. The Ring dipoles were changed to 160 A to minimize synchrotron oscillations and so improve storage. The orbit did not change.
Beam physics measurements to be started. |
ND, RC; Effet eclairage sur detecteurs RX
|
Effet de l'eclairage dans la casemate sur les detecteurs a RX (lumiere eteinte a 15:26:40) => il faut fonctionner avec la lumiere eteinte pour plus de sensibilite. |
Entered by Viktor Soskov from 134.158.195.153 on Tue Jun 13 15:00:13 2023; arret de la machine
|
Bonjour,
avant d'arrêter completement de la machine il faut absolument fermer le "Gate laser" via
1, LI/OP/OPT.02-LAS.01-ASP.01 - Gate_int -False
ou
2, Plateforme IHM ThomX - Ring- Start for ring - Close laser gate
Viktor. |
Entered by Viktor Soskov from 134.158.195.153 on Tue Jun 13 14:42:00 2023; arręt de la machine
|
Bonjour,
avant d'arrêter completement de la machine il faut absolument fermer le "Gate laser" via
1, LI/OP/OPT.02-LAS.01-ASP.01 - Gate_int -False
ou
2, Plateforme IHM ThomX - Ring- Start for ring - Close laser gate
Viktor. |
SC, ND; Effet changement de phase RF Canon sur TL/BPM.02
|
Quelques changements de phase canon. On voit que quand l'orbite derive vers des valeurs negatives sur Tl/BPM.02/SpX le fait de faire decroitre la phase rattrappe la position...
|
SC, ND; RE: Effet changement de phase RF Canon sur TL/BPM.02
|
Le code lock_position_tl_bpm_02.py a ete mis a jour pour prendre cet effet en compte.
| SC, ND wrote: |
|
Quelques changements de phase canon. On voit que quand l'orbite derive vers des valeurs negatives sur Tl/BPM.02/SpX le fait de faire decroitre la phase rattrappe la position...
|
|
VK, IC. VM; Reestablishing running conditions at 500.38 MHz    
|
Goal of the shift: Reestablish the good storage at 500.38 and then try to optimize the storage and orbit.
Start up of the machine.
RF cavity start up by Mohamed. Water leakage. Jean-Noel will fix tomorrow mornig. Mohamed also says that aparently the sinal from ring syntetizer is a bit noisy, to be checked with Nicolas.
problem with trigger of the TL BPM. Nicola fixed the problem. The cable was broken.
Load of the machine setting from 19/05. The injection in the ring is very unstable from shot to shot due to the tuning of the cavity. Coming to 100 kV @500.38 MHz synchronized with the ring. RF cavity works stable.
Beam on TL BPM.02 drifts a lot and very fast. See screenshots.
With the previous setting, we did not get the previous orbit. After small reoptimization we received the resonable storage. Still we should work on the orbit correction.
The main idea fo this week is to prepare the beam for the search of the first X-rays.
|
LS, MB, VC, ND; Programme prise de donnees 8/06   
|
9:23 Mise en chauffe
Nombreux pb vide dans health check
Acces casemate pour verification polarite RI-C2/DG/BPM.02 pas de probleme trouve.
Observation des soufflets pres de RI-C2/AE/DP.04 ils semblent legerement deformes mais pres de RI-C1/AE/DP.01 aussi.
11:30 Tentative de demarrage mais probleme temperature eau...
12:00 Intervention Maher. Demarrage possible.
Pb declenchement wavecatcher... Resolu (le serveur etait plante)
14:00 BPM polarity studies
15:30 Measure frequency
16:30 To to steer the beam around the chamber
18:20 Stop
===
Programme de la prise de données du 8/06:
0) During warm up:
0a)check physically BPMs where there seem to be a polarity issue (needs 2 persons, a battery and a multimeter).
0b) CHeck vacuum chamber around RI-C2/AE/DP.04
1) Transport to TL/FC.01 (TL/DP.01 off). Record FC signal
2) Transport to TL/SST.02 and TL/BPM.02. Record BPM adc signal while closing dispersion (for Mouad's studies).
3) Transport to EL/FC.01. Record FC signal and compare with TL/FC.01. If needed swap filters and compare again.
4) Activate position feedback on TL/BPM.02
5) Inject in ring, no RF power. Record with high res oscilloscope travel time for different magnets settings. If needed use a mixer.
6) Study the effect of correctors around RI-C2/AE/DP.04
7) Use extraction kicker scan to measure beam travel time after several turns
8) Finish BPM polarities study
9) Repeat (5) and (7) with different RF powers at 2 different frequencies (500.0202MHz and 500.4MHz). Look at oscillations on TbtX and TbtY vs frequency.
|
ND, LS, IC, VK, VM; Studies on the Ring revolution frequency 8x
|
Goal: understanding of teh beam natural revolution frequency. Study the effect of the dipoles.
We have started from the previous setting of the machine. Then we loaded the settings from last december and received better storage. RF cavity is OFF.
By working with the spectrum analyzer, we understood that previous measurements very probably were affected by the noise coming from the synthetizer, so the frequency measured corresponded to the synthetizer frequency.
At the same time, during the investigation, apart of the false peak given by the synthetizer frequency, there was some signals (difficult to interpratete) aroung 500.4 MHz. Investigations are ongoing.
In parallel, we are checking the BPM cabling convention by using the beam to be sure about the orbit readings.
Study of signal on scope:
Yellow: Losses monitor
Green: Sum of 4 electrodes RIC2/BPM.06
Blue: Long open cable (background pickup)
Screenshot from 2023-05-31 15-14-12.png Beam stored only for 1 turn not reaching
Screenshot from 2023-05-31 15-18-05.png: Green (BPM sum) cable disconnected
Screenshot from 2023-05-31 15-19-40.png: Green (BPM sum) cable reconnected
15:30 Checking BPM polarities
16:30 Created IHM to lock position on TL/DG/BPM.02 : Diags/BPM/lock_position_tl_bpm_02.py
16:32 reload ring recipe
Screenshot from 2023-05-31 16-35-21.png : BPM signal with current in ring
Screenshot from 2023-05-31 16-49-49_I_159_3.png
Screenshot from 2023-05-31 16-51-58_I_161_90.png
Screenshot from 2023-05-31 16-56-12_I_157_90.png
Screenshot from 2023-05-31 17-02-41_I_159_90.png
Screenshot from 2023-05-31 17-03-15_I_161_90.png
Screenshot from 2023-05-31 17-10-02_I_157_90.png
Screenshot from 2023-05-31 17-11-53_I_161_90.png
Screenshot from 2023-05-31 17-13-59_I_157_90.png : We see the markers at the two node position. Delta X = 900ps
Screenshot from 2023-05-31 17-21-18_I_157_90.png : 3ns/div
When we change the dipole current we confirm that time to come back to the BPM change...
17h25: Machine stop |
ND, LS, IC, VK, VM; RE: Studies on the Ring revolution frequency
|
Bonjour,
Pouvez vous enregistrer les images de l'oscilloscope et le donnée brute à la place des screenshots. Il y a une option dans l'interface web pour enregistrer l'oscillogramme "proprement". De même pour les images, cela permet de faire des traitements à posteriori.
Merci.
| ND, LS, IC, VK, VM wrote: |
|
Goal: understanding of teh beam natural revolution frequency. Study the effect of the dipoles.
We have started from the previous setting of the machine. Then we loaded the settings from last december and received better storage. RF cavity is OFF.
By working with the spectrum analyzer, we understood that previous measurements very probably were affected by the noise coming from the synthetizer, so the frequency measured corresponded to the synthetizer frequency.
At the same time, during the investigation, apart of the false peak given by the synthetizer frequency, there was some signals (difficult to interpratete) aroung 500.4 MHz. Investigations are ongoing.
In parallel, we are checking the BPM cabling convention by using the beam to be sure about the orbit readings.
Study of signal on scope:
Yellow: Losses monitor
Green: Sum of 4 electrodes RIC2/BPM.06
Blue: Long open cable (background pickup)
Screenshot from 2023-05-31 15-14-12.png Beam stored only for 1 turn not reaching
Screenshot from 2023-05-31 15-18-05.png: Green (BPM sum) cable disconnected
Screenshot from 2023-05-31 15-19-40.png: Green (BPM sum) cable reconnected
15:30 Checking BPM polarities
16:30 Created IHM to lock position on TL/DG/BPM.02 : Diags/BPM/lock_position_tl_bpm_02.py
16:32 reload ring recipe
Screenshot from 2023-05-31 16-35-21.png : BPM signal with current in ring
Screenshot from 2023-05-31 16-49-49_I_159_3.png
Screenshot from 2023-05-31 16-51-58_I_161_90.png
Screenshot from 2023-05-31 16-56-12_I_157_90.png
Screenshot from 2023-05-31 17-02-41_I_159_90.png
Screenshot from 2023-05-31 17-03-15_I_161_90.png
Screenshot from 2023-05-31 17-10-02_I_157_90.png
Screenshot from 2023-05-31 17-11-53_I_161_90.png
Screenshot from 2023-05-31 17-13-59_I_157_90.png : We see the markers at the two node position. Delta X = 900ps
Screenshot from 2023-05-31 17-21-18_I_157_90.png : 3ns/div
When we change the dipole current we confirm that time to come back to the BPM change...
17h25: Machine stop
|
|
MJ, KD; RF et anneau 
|
Apres 18h30 : prise ne main de la machine pour aller dans la LE ==> le kicker d'extraction est interlocké (abdandon)
Essaie avec la derniere recette de l'anneau : à 159.3A le stockage n'est pas tres bon (cavité OFF)
On essai de jouer sur le plongeur pour accorder la cavité à la fréquence de révolution du paquet (voir 2 screenshot de l'oscilloscope).
La cavité à une forte influence sur le stockage, mais la forme n'est pas la même
- au nominal (24.4mm) où le faisceau semble mieux "entrer" dans l'anneau mais "meurt" plus vite.
- à 22.4 mm le faisceau semble vivre dans l'anneau plus longtemps mais est moins bien stocké. Quelle est la fréquence associé à cette valeur de plongeur ?
* Est ce qu'il n'y a pas à creuser sur l'accord de la cavité au faisceau ?
* La fréquence principale de la FFT (16.68MHz) ne semble pas bouger (que ce soit avec les dipôles ou avec la cavité RF). Que représente cette valeur ?
20h30 : machine à l'arrêt |
MJ, KD; RE: RF et anneau
|
|
Mercredi 24 j'ai fait un test sur la cavité RF :
- Au début la LLRF étant ON alors que la cavité était OFF, est ce normale ?
- Le moteur du plongeur était à 24.91 mm
- J'ai donc allumé la cavité avec 0V en consigne (sans puissance), il y a tout de même 5kV je crois en résiduel au minimum.
- J'ai mis le plongeur à 24.4mm et à 500.4MHz, attendu que la cavité se stabilise avec le LLRF
- J'ai coupé le LLRF, et fait le changement du plongeur à 22.4mm, et ré-accorder la cavité avec la fréquence, j'ai trouvé une fréquence de l'ordre de 500.3MHz.
- J'ai tout remis comme avant (fréquence : 500.4MHz, plongeur 24.91 et attendu que la LLRF se stabilise) et j'ai tout mis OFF, cavité et LLRF.
A confirmer qu'un delta de 2mm sur le plongeur génère un delta de fréquence de l'ordre de 100 kHz ?
| MJ, KD wrote: |
|
Apres 18h30 : prise ne main de la machine pour aller dans la LE ==> le kicker d'extraction est interlocké (abdandon)
Essaie avec la derniere recette de l'anneau : à 159.3A le stockage n'est pas tres bon (cavité OFF)
On essai de jouer sur le plongeur pour accorder la cavité à la fréquence de révolution du paquet (voir 2 screenshot de l'oscilloscope).
La cavité à une forte influence sur le stockage, mais la forme n'est pas la même
- au nominal (24.4mm) où le faisceau semble mieux "entrer" dans l'anneau mais "meurt" plus vite.
- à 22.4 mm le faisceau semble vivre dans l'anneau plus longtemps mais est moins bien stocké. Quelle est la fréquence associé à cette valeur de plongeur ?
* Est ce qu'il n'y a pas à creuser sur l'accord de la cavité au faisceau ?
* La fréquence principale de la FFT (16.68MHz) ne semble pas bouger (que ce soit avec les dipôles ou avec la cavité RF). Que représente cette valeur ?
20h30 : machine à l'arrêt
|
|