08h25 Start ThomX: Modulator, Frigo, cycling all magnets
08h30 Start chillers
10h00 HV is 'On'
10h25 RF Gun Phase is 193 dg., Sect. Att. is 2.46 dB, Phase is 218 dg. Charges: -98 pC, -105 pC, -106 pC
Linac steerers: H [2.38 -4.16], V [-1.8 2.15]
Ring injection. After cycling Ri-C1 QP5 is out of order, fixed
10h30 Beam is in the ring, Rec. from 20250109_17_23, TL/BPM02 X=+3 mm
11h00 setings for ring without sextupoles for LOCO
11h04 setings for ring without sextupoles for LOCO (Matlab config file) is saved
The same with sextupoles.
Trying LOCO with sextupoles: LOCO inprove results on storage and tune. Tune changed from 0.15 to 0.17
13h30 HV is 'Off'. Controled access to the bunker.
13h55 HV is 'On'
/tmp_mnt/data/shared/commissioning_scripts/MatLab/pilotage/libera_calctunesS_ThomxOperateur.m to measure tune from operateut.thomx account
16h55 Stop ThomX
|