11h05 Start ThomX

11h50 BPM02-Libera04 wiring has been checked: 'OK' 

12h20 HV is 'ON' 1215 V

12h31 RF Gun phase is 179 dg.

12h48 RF Gun phase is 181 dg. Sect. Att. 2.534 dB, Phase is 213 dg. Linac Steerers H [2.98 -4.66], V [-1.8 2.15]

14h50 HV on Standby. Controlled access

15h20 HV is 'ON'

17h50 Reajust linac transport: linac steerers H [2.38 -4.18], V [-1.9 2.05]  Charge -121 pC, -114 pC, -123 pC

18h55 Stop ThomX