Message ID: 951     Entry time: Thu Oct 31 08:19:25 2024
 Author: KDn Dupraz from 109.222.35.58 on Thu Oct 31 08:19:12 2024 
 Status: Under Process 
 Type: Shift summary 
 Category: Ring Commissioning 
 Important:
 Subject: shift du 31 octobre 2024 
 Icon:  

8h15: mise en chauffe en remote (modulateur, laser, chiller, Cycling)

Tuning of the linac and injection to the ring

Goal: Search for the non-dispersive orbit and proper RF frequency

We started from F =500.059 MHz

Frequency change from 500.05 to 500.0853 MHz

We stopped at 500.0853 MHz and proceeded with the orbit correction

3 steereres are at max values. Studies continue to understand the other possibilities of corection.

18h Stop ThomX

 