8h47 Mise en chauffe modulateur et chillers
- Phase Q max : 161 deg
1. ALIGNEMENT laser-cathod
a) Alignement dark current (X=5.2 Y=2.05)
phase =161 YAGLI X = 420 Y = 350
BPMLI X = - 0.9 Y = - 1.7
phase=154 YAGLI X = 400 Y = 300
BPMLI X = 1.1 Y = 0.9
--> DX_YAG = 20 DY_YAG = 50 DX_BPM = 2.0 DY_BPM = 2.6
b) Alignement BPM (X=5.41 Y=2.35)
phase =161 YAGLI X = 460 Y = 275
BPMLI X = 1.0 Y = 1.0
phase=154 YAGLI X = 450 Y = 290
BPMLI X = 1.2 Y = 1.0
--> DX_YAG = 10 DY_YAG = 15 DX_BPM = 0.2 DY_BPM = 0
c) Alignement YAG (X=5.404 Y=2.32)
phase =161 YAGLI X = 465 Y = 280
BPMLI X = 1.0 Y = 1.0
phase=154 YAGLI X = 440 Y = 290
BPMLI X = 1.25 Y = 1.0
--> DX_YAG = 25 DY_YAG = 10 DX_BPM = 0.25 DY_BPM = 0
--> Alignement BPM ou YAG equivalent -- Alignement DARK current moins bien
--> On se met a point cathode : X = 5.405 Y = 2.34 ( = moyenne BPM et YAG)
2. ALIGNEMENT SOLENO :
Check alignement soleno --> Realignement avec le script
Resultat :
LI/AE/COL.01-MOT.01 = 0.783 mm;
LI/AE/COL.01-MOT.02 = 3.427 mm;
LI/AE/COL.02-MOT.01 = 10.451 mrad ;
LI/AE/COL.02-MOT.02 = -4.359 mrad;
Check avec ces valeurs :
SOLENO = 250 YAGLI X = 480 Y = 300
BPMLI X = 1.5 Y = 1.7
SOLENO = 120 YAGLI X = 370 Y = 305
BPMLI X = 1.6 Y = 0.9
--> DX_YAG = 10 DY_YAG = 5 DX_BPM = 0.1 DY_BPM = 0.8 - Le script, meme apres plein de passages, ne donne pas mieux ...
3. ALIGNEMENT SECTION : L'alignement section a ete a reprendre car le point cathode est different (vu qu'on ne prend plus le point "dark current")
** Axe pas trop mal pour commencer : LI/STR.01 [H,V] = [0.93, -0.9]
LI/STR.02 [H,V] = [-2.86, 1.41]
** Tableau excel ensuite (cf resultat en pj)
** Pour demain : Tableau excel (prochain_alignement_section.xlsx) pour le vertical : en pj (Il faudra sans doute refaire un passage "tableau excel" plus fin en vertical apres celui-la).
PUIS : verifier ce que ce nouvel axe donne pour Q1-Q3 (= ok ? ou pas ok ?)
Salutti
|