10h50 Mise en route à 10dB, HT = 1000V
11h04 HT = 1215V, Att sec 3 dB vide in section = 9.3e-9 vide out section = 1e-9
11h05 HT = 1215V, Att sec 2 dB vide in section = 9.4e-9 vide out section = 1e-9
11h06 HT = 1215V, Att sec 1 dB
Interlock à 1dB
11h06 HT = 1215V, Att sec 1 dB vide in section = 7.2e-9 vide out section = 1.2e-9
11h16 Att sec 0.9dB vide in section = 8.5e-9 vide out section = 2.5e-9
11h21 Att sec 0.8dB vide in section = e-9 vide out section = e-9
11h27 Att sec 0.7dB vide in section = 9.5e-9 vide out section = 6.8e-9
11h32 Att sec 0.6dB vide in section = 9.2e-9 vide out section = 7.9e-9
11h38 Att sec 0.5dB (Pis=22MW) vide in section = e-9 vide out section = e-9
12:39 : Interlock ? (scope Auto -> Norm to catch last signal)
12:51 : Interlock section
13:28 : Att sec 0.5dB (Pis=22MW)
14h03 Interlock à 0.5 dB
14h07 Att sec 0.4 dB vide in section = e-9 vide out section = e-9
14h50 interlock 0.4 dB
17h40 interlock 0.4 dB
18h55 fin
|