Message ID: 637     Entry time: Thu Dec 1 01:14:36 2022
 Author: Entered by Nicolas Delerue from 80.119.21.73 on Thu Dec 1 01:14:20 2022 
 Status: New Solution 
 Type: Shift summary 
 Category: Ring | Diag 
 Important:
 Subject: Beam time / Thursday 1st December 
 Icon:  

9:10 Il y a quelqu'un de DEKRA qui deambule seul dans l'IGLEX sans dosimetre. A-t-il ete prevenu du risque?

9:15: La console operateur etait laissee ouverte avec de nombreuses fenetres ouvertes...

9:18 Resistivite eau: 5.5 Mo

Pression air comprime 7 bars.

9:20 Mise en chauffe de modulateur

Heath check OK

9:40 Cyclage aimants

10:40 Beam on

10:53 Scan charge vs phase. Cf plots joints

10:56 Chargement recette test_20221130_17_33_59 ne passe pas la cavite

11:10 Faisceau non trouve dans TL/SST.02

Temperature chiller elevee

11:20 La phase a change

11:30 Realignement mirroir par Viktor.

Cavite desaccordee

11:49 Mise du modulateur en standby

=> attente 30 minutes

11:49 Mohamed a confirme que la cavite RF anneau est detune pour permettre les operations anneau.

11:50 Jean Noel accede a la casemate.

12:15 Scan charge phase demare

12:25 Nouvelle phase charge max: 175

Des claquages pendant le scan.

12:31 Faisecau sur TL/DG/SST1

12:32 Chargement recette test_20221130_17_33_59

12:40  faisceau sur TL/DG/SST.02

Recherche phase section

Charge max LI/DG/ICT.01 > 100pC => Attenuateur laser a 341mm

13:01 Phase section: 95

13:05 Faisceau sur TL/DG/SST.03

Start EP

13:08 Recette sauvee dans all_20221201_13_08

15:35 Modulator crashed + recovered

16:55 Phase section 93. Scan tres bruyant

Difficultes a injecter dans l' anneau.

17:35 Injection dans l 'anneau retrouvee

===

Plan for the beam time:

1) Re-establish transport to the ring

2) Inject in the ring

3) Save ring recipe

4) Check BPMs in AGC mode

5) Check screens calibration

6) Changement mesure taille SST

Attachment 1: health_check.png  21 kB  Uploaded Thu Dec 1 09:40:25 2022  | Show | Hide all | Show all
Attachment 2: scan_charge_phase_min_0.0_max_360.0_10_51_43.png  47 kB  Uploaded Thu Dec 1 10:53:25 2022  | Show | Hide all | Show all
Attachment 3: scan_charge_phase_min_140.0_max_220.0_10_53_7.png  48 kB  Uploaded Thu Dec 1 10:53:32 2022  | Hide | Hide all | Show all
scan_charge_phase_min_140.0_max_220.0_10_53_7.png
Attachment 4: scan_charge_phase_min_160.0_max_240.0_11_21_32.png  53 kB  Uploaded Thu Dec 1 11:25:04 2022  | Hide | Hide all | Show all
scan_charge_phase_min_160.0_max_240.0_11_21_32.png
Attachment 5: Screenshot_from_2022-12-01_11-48-20.png  48 kB  Uploaded Thu Dec 1 11:48:45 2022  | Hide | Hide all | Show all
Screenshot_from_2022-12-01_11-48-20.png
Attachment 6: Screenshot_from_2022-12-01_12-16-00.png  50 kB  Uploaded Thu Dec 1 12:16:13 2022  | Show | Hide all | Show all
Attachment 7: dispersion_13_3_31.png  39 kB  Uploaded Thu Dec 1 13:04:13 2022  | Hide | Hide all | Show all
dispersion_13_3_31.png
Attachment 8: dispersion_16_54_28.png  37 kB  Uploaded Thu Dec 1 16:55:50 2022  | Show | Hide all | Show all
Attachment 9: dispersion_17_24_54.png  33 kB  Uploaded Thu Dec 1 17:26:16 2022  | Hide | Hide all | Show all
dispersion_17_24_54.png
Attachment 10: dispersion_17_28_14.png  35 kB  Uploaded Thu Dec 1 17:29:11 2022  | Hide | Hide all | Show all
dispersion_17_28_14.png
Attachment 11: quad_scan_tl_dg_sst.03_20221201_16_3x.png  37 kB  Uploaded Thu Dec 1 17:34:46 2022  | Hide | Hide all | Show all
quad_scan_tl_dg_sst.03_20221201_16_3x.png
ELOG V3.1.4-395e101