Message ID: 500     Entry time: Thu Jul 7 19:49:05 2022
 Author: Entered by Super Team from 134.158.195.141 on Thu Jul 7 19:48:47 2022 
 Status:  
 Type: Shift summary 
 Category: Linac Commissionning 
 Important:
 Subject:  
 Icon:  

Alignement laser/canon

col2 185A col1 53.4

str1H -0.9 str1V 0

charge transmise entierement

Check de l'axe magnetique de la section :

phase section 80    bpmtl x y  +2.3 -2.2     yagtl x y 13.1  9.4

                       90                    +2.3 -2.2                    13.2  9.6

                       100                    +2.4 -2.2                    13.3  9.5

                       110                   +2.4 -2.2                    13.2  9.4

                       120                    +2.6 -2.3                    13.4  9.6

                       130                    +2.9 -2.3                    13.5  9.5

                       140                    +3.5 -2.3                    13.8  9.2

l'axe mag LIL nous parait correct avec strh1 -0.9 et str1v 0

salut

JN et MJ

 

                      

 