HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Commissionning Commissionning Preparation Pannes ShiftCheck
  Toutes les notes concernant les Commissionning de ThomX  Not logged in ThomX    logo
Entry   Entered by Viktor Soskov from 134.158.195.153 on Thu Apr 7 11:31:17 2022; Laser status 
    Reply   Entered by Viktor Soskov from 134.158.195.153 on Thu Apr 7 11:31:17 2022; RE: Laser status 2022-04-07_12_27_54_li_op_las_02_Laser_log_scale_False_despeckle_False_min_scale_0_max_scale_30_8.png2022-04-07_12_50_39_li_op_las_02_Laser_log_scale_False_despeckle_False_min_scale_0_max_scale_30_8.png
Message ID: 434     Entry time: Thu Apr 7 12:51:41 2022     In reply to: 433
 Author: Entered by Viktor Soskov from 134.158.195.153 on Thu Apr 7 11:31:17 2022 
 Status: Fixed 
 Type: Info 
 Category: Linac Commissionning 
 Important:
 Subject: RE: Laser status 
 Icon:  

 

Entered by Viktor Soskov from 134.158.195.153 on Thu Apr 7 11:31:17 2022 wrote:

Hublot_1 (dans la salle laser) a été enlevé, hublot_2 (casemate) - changé pour CaF2.

L'nergie sur la cathode = 62µJ (IRIS=3mm)

Stabilité :

La stabilité reste bonne

mean x 5460.00 µm    +/- 10.14 µm
mean y 3173.65 µm    +/- 8.58 µm
FWHM x 928.64 µm    +/- 67.32 µm
FWHM y 918.32 µm    +/- 26.75 µm

Iris : on est passé de 3mm à 1.5 mm.

ELOG V3.1.4-395e101