 Subject: résumé de l'intervention Scandinova 
 Icon:  

Bonjour

Voici le resumé de l'intervention Scandinova tiré du rapport de l'intervention du 07/02/2022 à 09/02/2022

***********************************

Summary of Work

Replaced EP2316-0008 module

Increased filters on HIU for Standby and HV

Increased filter for IntCom interlock

Suggested some mesh to added between Klystron and rack for EMC protection

Corrected some software parameters relating to filament and SPS to increase functionality

Reduced filters for water flow switches due to glitching averaging

A 24h Long Run was carried out. Modulator kept in HV for 24h prior

Conclusion

Problem did not occur while on site, actions taken to reduce the risk of unneccessary interlocks were taken

***************************************