Message ID: 175     Entry time: Tue Nov 23 10:56:50 2021
 Author: Entered by Iryna Chaikovska from 134.158.195.143 on Tue Nov 23 10:56:34 2021 
 Status: Fixed 
 Type: Other 
 Category: Aimants | Linac Commissionning 
 Important:
 Subject: Cyclage dipole 
 Icon:  

 For 22/11/2021

There is the remaining field from the dipoles in the TL. In order to go straight to the dump, the idea was to cycle the dipole to have 0 field. We have tried the cyclage given by the ALBA peopel/Cynthia. Total time ~ 17 min. After two cycling, the remaining filed alwayd stays at ~20 G.

After discussion of Jean-Noel with Fabrice Marteau, this turned out normal situation given the unipolar PS of the dipoles. The remaining filed is kind in agreement with B(I) found in excel files provided long time ago by Cynthia.

The information concerning the dipole cycling from Cynthia is attached.