HOME Prise de donnees MML Controle commande Simulations Notes Hardware Ligne X Laser Interaction Diagnostiques Synchronisation
Commissionning Commissionning Preparation Pannes ShiftCheck
  Toutes les notes concernant les Commissionning de ThomX  Not logged in ThomX    logo
Message ID: 1226     Entry time: Tue Apr 7 07:49:37 2026
 Author: IC,VM, KD, DN, MJ 
 Status: Under Process 
 Type: Shift summary 
 Category: Linac Commissionning | Ring Commissioning 
 Important:
 Subject: MONO 61.5 MeV - 07 avril 2026 
 Icon:  

7h50 : mise en chauffe en remote (frigo/chillers, modulateur, laser, cyclage)
09h30 HV is ON

10h23 Energy = 61.5 MeV, Laser Phase 39 dg., Sect. Phase 225 dg., Sect. Att. 0.952 dB, I_Gun -78.1953 pC, I_Linac -122.7687 pC, I_TL -102.6104 pC RF_Ampl. 148.7161 kV, RF_Phase -45.5 dg.
 

*** Mesure Monochromateur 61.5MeV ***

* angle initiale mono : Ry_mono(0) = -0.1° (ajouté aux valeurs d'angles pour la position moteur)

* Position fentes initiale [-19;-16]

Point On Axis :

   - Angle Mono 1.5° --> position RSample : 3.5°

  - Angle Mono 1.6° --> position RSample : 3.7° 

  - Angle Mono 1.7° --> position RSample : 3.9°

   - Angle Mono 1.8° --> position RSample : 4.1°

H +30mm (position hexapod TX = -12):

   - Angle Mono 1.8° --> position RSample : 3.7°

   - Angle Mono 2° --> position RSample : 4.1°

H +40mm (position hexapod TX = -23):

   - Angle Mono 1.8° --> position RSample : 3.6°

   - Angle Mono 2° --> position RSample : 4°

H -30mm (position hexapod TX = 53):

   - Angle Mono 1.5° --> position RSample : 3.9°

   - Angle Mono 1.6° --> position RSample : 4.1°

   - Angle Mono 1.8° --> position RSample : 4.5°

H -40mm (position hexapod TX = 64):

   - Angle Mono 1.5° --> position RSample : 4°

   - Angle Mono 1.6° --> position RSample : 4.2°

   - Angle Mono 1.8° --> position RSample : 4.6°

V +30mm (position hexapod TX = 21, TY : 30):

   - Angle Mono 1.5° --> position RSample : 3.5°

   - Angle Mono 1.6° --> position RSample : 3.7°

   - Angle Mono 1.8 --> position RSample : 4.1°

V -30mm (position hexapod TX = 21, TY : -30):

   - Angle Mono 1.5° --> position RSample : 3.5°

   - Angle Mono 1.6° --> position RSample : 3.7°

   - Angle Mono 1.8 --> position RSample : 4.1°

 

*** Images pilatus (thershold 30keV) ==> position On Axis, avec Rsample = 2°

1.8° :

452 (expo 2s), 453 (expo 5s), 454 (expo 10s), 455 (expo 20s)

1.5° :

456 (expo 20s), 457 (expo 20s), 458 (expo 10s)

2° :

459 (expo 20s), 460 (expo 20s), 461 (expo 30s), 465 (expo 20s)

 

*** Re-reglage streak camera (car completement dereglee)

longueur paquet : 40 ps fwhm (idem injection et apres injection)

ELOG V3.1.4-395e101